Patient-specific QA in MLC-based GRID therapy

被引:0
|
作者
Gao, W. [1 ]
Penagaricano, J. [1 ]
Moros, E. [1 ]
Corry, P. [1 ]
Griffin, R. [1 ]
Ivy, A. [1 ]
Youssef, E. [1 ]
Ratanatharathorn, V. [1 ]
机构
[1] Univ Arkansas Med Sci, Little Rock, AR 72205 USA
关键词
D O I
10.1118/1.2760999
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: GRID Therapy is an effective technique in treating large tumors and involves large doses in single fractions. This work is to present some dosimetric characteristics of MLC‐based GRIDs, and patient‐specific QA procedures at our institution based on film and diode dosimetry; Methods and Materials: 14 patients received GRID therapy treatments of 1500–2000 cGy at Dmax(1.5cm) in a single fraction with 6 MV photons from January 2006 to February 2007. The treatments were planned on the Pinnacle TPS using a step‐and‐shoot technique to generate chess‐board‐like patterns consisting of abutting opened‐and‐closed cells of 1cm×1cm. The treatments were delivered on a Varian Clinac 21EX with 120MLC. QA for each patient was performed with Kodax EDR2 film placed in a solid water phantom irradiated with the GRID field at normal angle and treatment SSD. Based on the measured optical density and QA MU, the MU to deliver the prescribed dose is calculated and compared with that given by the TPS for the same irradiation geometry. Similar measurements were also carried out with a diode detector in a water phantom; Results: MU derived from film measurements were consistently lower than those given by the TPS, from 1%–7%. Possible causes may be: (1) film over‐response due to high‐Z material and low energy photons in the tail region of dose profile; and (2) small variations in MLC leaf positions having measurable effect on the output of small GRID beamlets. The MUs derived from diode measurements are generally higher than and within 2% from those obtained with films. The valley‐to‐peak ratio ranged from 22%–29%, primarily depending on the number of segments in the beams. Conclusion: With the understanding of their advantages as well as limitations, both film and diode can be effectively used in routine plan verification for GRID therapy. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2479 / 2479
页数:1
相关论文
共 50 条
  • [41] Tolerance design of patient-specific range QA using the DMAIC framework in proton therapy
    Rah, Jeong-Eun
    Shin, Dongho
    Manger, Ryan P.
    Kim, Tae Hyun
    Oh, Do Hoon
    Kim, Dae Yong
    Kim, Gwe-Ya
    MEDICAL PHYSICS, 2018, 45 (02) : 520 - 528
  • [42] Application of Six Sigma Approach to Improve the Efficiency of Patient-Specific QA in Proton Therapy
    Lah, J.
    Shin, D.
    Manger, R.
    Kim, G.
    MEDICAL PHYSICS, 2016, 43 (06) : 3336 - 3336
  • [43] Predicting the error magnitude in patient-specific QA during radiotherapy based on ResNet
    Huang, Ying
    Pi, Yifei
    Ma, Kui
    Miao, Xiaojuan
    Fu, Sichao
    Feng, Aihui
    Duan, Yanhua
    Kong, Qing
    Zhuo, Weihai
    Xu, Zhiyong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2024, 32 (03) : 797 - 807
  • [44] Planar EPID-Based Dosimetry for SRS and SRT Patient-Specific QA
    Thongsawad, Sangutid
    Chanton, Tadchapong
    Saiyo, Nipon
    Udee, Nuntawat
    LIFE-BASEL, 2021, 11 (11):
  • [45] Complexity metric as a complement to measurement based IMRT/VMAT patient-specific QA
    Gotstedt, J.
    Hauer, A. Karlsson
    Back, A.
    8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [46] Clinical Implementation of Deep Learning-Based VMAT Patient-Specific QA
    Yang, X.
    Wang, L.
    Li, D.
    Guo, Y.
    Li, Y.
    Guan, Y.
    Wu, X.
    Xu, S.
    Zhang, S.
    Chan, M.
    Yang, R.
    Geng, L.
    Sui, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [47] Evaluation of MLC-Based Robotic Radiotherapy
    Fahimian, B.
    Soltys, S.
    Xing, L.
    Gibbs, I.
    Chang, S.
    Wang, L.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [48] Dosimetric Effect on AI Based Virtual Log File Patient-Specific QA
    Chuang, K. C.
    Wu, Y.
    Lay, L. M.
    Cui, G.
    O'Daniel, J. C.
    Adamson, J.
    MEDICAL PHYSICS, 2024, 51 (09) : 6602 - 6602
  • [49] Implementation of a Non-Measurement-Based Patient-Specific IMRT QA Program
    Chen, S.
    Guerrero, M.
    Zhang, B.
    Yi, B.
    Mossahebi, S.
    Prado, K.
    D'Souza, W.
    Langen, K.
    MEDICAL PHYSICS, 2016, 43 (06) : 3687 - 3687
  • [50] EPID-Based in Vivo Dosimetry: The Next Step in Patient-Specific QA
    Mijnheer, B.
    Olaciregui-Ruiz, I.
    Rozendaal, R.
    Sonke, J-J
    Spreeuw, H.
    Tielenburg, R.
    van Herk, M.
    Mans, A.
    MEDICAL PHYSICS, 2013, 40 (06)