Patient-specific QA in MLC-based GRID therapy

被引:0
|
作者
Gao, W. [1 ]
Penagaricano, J. [1 ]
Moros, E. [1 ]
Corry, P. [1 ]
Griffin, R. [1 ]
Ivy, A. [1 ]
Youssef, E. [1 ]
Ratanatharathorn, V. [1 ]
机构
[1] Univ Arkansas Med Sci, Little Rock, AR 72205 USA
关键词
D O I
10.1118/1.2760999
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: GRID Therapy is an effective technique in treating large tumors and involves large doses in single fractions. This work is to present some dosimetric characteristics of MLC‐based GRIDs, and patient‐specific QA procedures at our institution based on film and diode dosimetry; Methods and Materials: 14 patients received GRID therapy treatments of 1500–2000 cGy at Dmax(1.5cm) in a single fraction with 6 MV photons from January 2006 to February 2007. The treatments were planned on the Pinnacle TPS using a step‐and‐shoot technique to generate chess‐board‐like patterns consisting of abutting opened‐and‐closed cells of 1cm×1cm. The treatments were delivered on a Varian Clinac 21EX with 120MLC. QA for each patient was performed with Kodax EDR2 film placed in a solid water phantom irradiated with the GRID field at normal angle and treatment SSD. Based on the measured optical density and QA MU, the MU to deliver the prescribed dose is calculated and compared with that given by the TPS for the same irradiation geometry. Similar measurements were also carried out with a diode detector in a water phantom; Results: MU derived from film measurements were consistently lower than those given by the TPS, from 1%–7%. Possible causes may be: (1) film over‐response due to high‐Z material and low energy photons in the tail region of dose profile; and (2) small variations in MLC leaf positions having measurable effect on the output of small GRID beamlets. The MUs derived from diode measurements are generally higher than and within 2% from those obtained with films. The valley‐to‐peak ratio ranged from 22%–29%, primarily depending on the number of segments in the beams. Conclusion: With the understanding of their advantages as well as limitations, both film and diode can be effectively used in routine plan verification for GRID therapy. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2479 / 2479
页数:1
相关论文
共 50 条
  • [31] Experience on patient-specific QA for HyperArc stereotatic plans
    Calvo-Ortega, Juan-Francisco
    Moragues-Femenia, Sandra
    Laosa-Bello, Coral
    Pozo-Masso, Miquel
    Zamora-Perez, Antonia
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4735 - S4737
  • [32] The limitation of patient-specific QA in IMRT with detector arrays
    Huh, S.
    Cho, W.
    Park, Y.
    MEDICAL PHYSICS, 2006, 33 (06) : 2143 - 2143
  • [33] Patient-Specific QA for HDR Brachytherapy Skin Treatments
    Palaniswaamy, G.
    Massingill, B.
    Deb, N.
    Mutyala, S.
    Rangaraj, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [34] Improvement of deep learning prediction model in patient-specific QA for VMAT with MLC leaf position map and patient's dose distribution
    Tozuka, Ryota
    Kadoya, Noriyuki
    Tomori, Seiji
    Kimura, Yuto
    Kajikawa, Tomohiro
    Sugai, Yuto
    Xiao, Yushan
    Jingu, Keiichi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (10):
  • [35] Evaluation of the ArcCHECK device for commissioning and patient-specific QA
    Shahine, B.
    Badragan, I.
    Ramaseshan, R.
    MEDICAL PHYSICS, 2012, 39 (07) : 4633 - 4633
  • [36] SRS/SBRT Patient-Specific QA Device Comparison
    Epstein, D.
    Shacham, T.
    Levin, D.
    MEDICAL PHYSICS, 2022, 49 (06) : E948 - E948
  • [37] Evaluation of SRS MapCHECK™ for SABR patient-specific QA
    Miao, Y.
    Kidane, G.
    Ifthaker, A.
    Crees, L.
    Almond, E.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S743 - S743
  • [38] Evaluation of the SRS MapCHECK for CyberKnife Patient-Specific QA
    Davis, S. D.
    Acha, A.
    George, S.
    Romaguera, W.
    Tirpak, L.
    Mishra, V.
    Gutierrez, A.
    MEDICAL PHYSICS, 2019, 46 (06) : E647 - E647
  • [39] Developing a comprehensive patient-specific QA procedure for IMRT
    Luo, W.
    Li, J.
    Price, R.
    Chen, L.
    Fan, J.
    Chen, Z.
    Lin, T.
    Wang, L.
    Ma, C.
    MEDICAL PHYSICS, 2006, 33 (06) : 2247 - 2248
  • [40] Validation of COMPASS System for RapidArc Patient-Specific QA
    Huang, H.
    Tsai, P.
    Huang, Y.
    Yeh, C.
    MEDICAL PHYSICS, 2011, 38 (06)