Parallax-free intra-operative X-ray image stitching

被引:33
|
作者
Wang, Lejing [1 ]
Traub, Joerg [1 ]
Weidert, Simon [2 ]
Heining, Sandro Michael [2 ]
Euler, Ekkehard [2 ]
Navab, Nassir [1 ]
机构
[1] Tech Univ Munich, Fak Informat, D-85748 Garching, Germany
[2] Ludwig Maximilians Univ Munchen, Klinikum Innenstadt, Dept Trauma Surg, Munich, Germany
关键词
X-ray image stitching; Camera Augmented Mobile C-arm; Computer aided surgery; FRACTURES; MALALIGNMENT; RADIOGRAPHY; ANGLE;
D O I
10.1016/j.media.2010.05.007
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We present a novel method to generate parallax-free panoramic X-ray images during surgery by enabling the mobile C-arm to rotate around its X-ray source center, relative to the patient's table. Rotating the mobile C-arm around its X-ray source center is impractical and sometimes impossible due to the mechanical design of mobile C-arm systems. In order to ensure that the C-arm motion is a relative pure rotation around its X-ray source center, we propose to move the table to compensate for the translational part of the motion based on C-arm pose estimation. For this we employ a visual marker pattern and a Camera Augmented Mobile C-arm system that is a standard mobile C-arm augmented by a video camera and mirror construction. We are able to produce a parallax-free panoramic X-ray image independent of the geometric configuration of imaged anatomical structures. Our method does not require a fronto-parallel setup or any overlap between the acquired X-ray images. This generated parallax-free panoramic Xray image preserves the linear perspective projection property. It also presents a negligible difference (below 2 pixels) in the overlapping area between two consecutive individual X-ray images and has a high visual quality. This promises suitability for intra-operative clinical applications in orthopedic and trauma surgery. The experiments on phantoms and ex-vivo bone structure demonstrate both the functionality and accuracy of the method. (C) 2010 Elsevier BM. All rights reserved.
引用
收藏
页码:674 / 686
页数:13
相关论文
共 50 条
  • [41] The use of intra-operative image intensifier control for the ACL surgeon
    Singh, A. P.
    Singh, B. K.
    KNEE, 2011, 18 (06): : 379 - 381
  • [42] Personalised image-based templates for intra-operative guidance
    Berry, E
    Cuppone, M
    Porada, S
    Millner, PA
    Rao, A
    Chiverton, N
    Seedhom, BB
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2005, 219 (H2) : 111 - 118
  • [43] Image Registration for CT and intra-operative ultrasound data of the liver
    Papenberg, Nils
    Lange, Thomas
    Modersitzki, Jan
    Schlag, Peter M.
    Fischer, Bernd
    MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2, 2008, 6918
  • [44] Safety of intra-operative vasopressor in free jejunal flap reconstruction
    Chan, Jimmy Yu Wai
    Chow, Velda Ling Yu
    Liu, Lawrence Hin Lun
    MICROSURGERY, 2013, 33 (05) : 358 - 361
  • [45] Stitching interferometry for ellipsoidal x-ray mirrors
    Yumoto, Hirokatsu
    Koyama, Takahisa
    Matsuyama, Satoshi
    Yamauchi, Kazuto
    Ohashi, Haruhiko
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (05):
  • [46] Intra-operative image guidance in otolaryngology - The use of the ISG viewing wand
    Carney, AS
    Patel, N
    Baldwin, DL
    Coakham, HB
    Sandeman, DR
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1996, 110 (04): : 322 - 327
  • [47] Pose estimation quality assessment for intra-operative image guidance systems
    Egli, Adrian
    Kleinszig, Gerhard
    John, Adrian
    Fernandez, Alberto
    Cardelino, Juan
    MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2013, 8671
  • [48] An algorithm for automatic stitching of CR X-ray images
    Gramer, Markus
    Bohlken, Wilfried
    Lundt, Bernd
    Pralow, Thomas
    Buzug, Thorsten M.
    Advances in Medical Engineering, 2007, 114 : 193 - 198
  • [49] Fast optimized Monte Carlo phase-space generation and dose prediction for low energy x-ray intra-operative radiation therapy
    Vidal, M.
    Ibanez, P.
    Guerra, P.
    Valdivieso-Casique, M. F.
    Rodrigues, R.
    Illane, C.
    Udias, J. M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (07):
  • [50] Rotational X-ray angiography: a method for intra-operative volume imaging of the left-atrium and pulmonary veins for atrial fibrillation ablation guidance
    Manzke, R.
    Zagorchev, L.
    d'Avila, A.
    Thiagalingam, A.
    Reddy, V. Y.
    Chan, R. C.
    MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509