Parallax-free intra-operative X-ray image stitching

被引:33
|
作者
Wang, Lejing [1 ]
Traub, Joerg [1 ]
Weidert, Simon [2 ]
Heining, Sandro Michael [2 ]
Euler, Ekkehard [2 ]
Navab, Nassir [1 ]
机构
[1] Tech Univ Munich, Fak Informat, D-85748 Garching, Germany
[2] Ludwig Maximilians Univ Munchen, Klinikum Innenstadt, Dept Trauma Surg, Munich, Germany
关键词
X-ray image stitching; Camera Augmented Mobile C-arm; Computer aided surgery; FRACTURES; MALALIGNMENT; RADIOGRAPHY; ANGLE;
D O I
10.1016/j.media.2010.05.007
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We present a novel method to generate parallax-free panoramic X-ray images during surgery by enabling the mobile C-arm to rotate around its X-ray source center, relative to the patient's table. Rotating the mobile C-arm around its X-ray source center is impractical and sometimes impossible due to the mechanical design of mobile C-arm systems. In order to ensure that the C-arm motion is a relative pure rotation around its X-ray source center, we propose to move the table to compensate for the translational part of the motion based on C-arm pose estimation. For this we employ a visual marker pattern and a Camera Augmented Mobile C-arm system that is a standard mobile C-arm augmented by a video camera and mirror construction. We are able to produce a parallax-free panoramic X-ray image independent of the geometric configuration of imaged anatomical structures. Our method does not require a fronto-parallel setup or any overlap between the acquired X-ray images. This generated parallax-free panoramic Xray image preserves the linear perspective projection property. It also presents a negligible difference (below 2 pixels) in the overlapping area between two consecutive individual X-ray images and has a high visual quality. This promises suitability for intra-operative clinical applications in orthopedic and trauma surgery. The experiments on phantoms and ex-vivo bone structure demonstrate both the functionality and accuracy of the method. (C) 2010 Elsevier BM. All rights reserved.
引用
收藏
页码:674 / 686
页数:13
相关论文
共 50 条
  • [31] Cochlear implant electrode array insertion monitoring with intra-operative 3D rotational X-ray
    Carelsen, B.
    Grolman, W.
    Tange, R.
    Streekstra, G. J.
    van, Kemenade P.
    Jansen, R. J.
    Freling, N. J. M.
    White, M.
    Maat, B.
    Fokkens, W. J.
    CLINICAL OTOLARYNGOLOGY, 2007, 32 (01) : 46 - 50
  • [32] Laboratory-based X-ray Phase Contrast CT technology for clinical intra-operative specimen imaging
    Massimi, Lorenzo
    Hagen, Charlotte K.
    Endrizzi, Marco
    Munro, Peter R. T.
    Havariyoun, Glafkos
    Hawker, P. M. Sam
    Smit, Bennie
    Astolfo, Alberto
    Larkin, Oliver J.
    Waltham, Richard M.
    Shah, Zoheb
    Duffy, Stephen W.
    Nelan, Rachel L.
    Peel, Anthony
    Suaris, Tamara
    Jones, J. Louise
    Haig, Ian G.
    Olivo, Alessandro
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [33] Dosimetry of a low-kV intra-operative X-ray source using basic analytical beam models
    Ebert M.A.
    Carruthers B.
    Lanzon P.J.
    Haworth A.
    Clarke J.
    Caswell N.M.
    Siddiqui S.A.
    Australasian Physics & Engineering Sciences in Medicine, 2002, 25 (3): : 119 - 123
  • [34] XIOSIS: An X-Ray-Based Intra-Operative Image-Guided Platform for Oncology Smart Material Delivery
    Hooshangnejad, Hamed
    China, Debarghya
    Huang, Yixuan
    Zbijewski, Wojciech
    Uneri, Ali
    McNutt, Todd
    Lee, Junghoon
    Ding, Kai
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2024, 43 (09) : 3176 - 3187
  • [35] Assessment of intra-operative surgical performance: proof of concept of complete intra-operative image documentation in orthopaedic trauma
    Regazzoni, P.
    Fernandez, A.
    Perren, S. M.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (01): : 7 - 8
  • [36] Improvement of automated image stitching system for DR X-ray images
    Yang, Fan
    He, Yan
    Deng, Zhen Sheng
    Yan, Ang
    COMPUTERS IN BIOLOGY AND MEDICINE, 2016, 71 : 108 - 114
  • [37] Clinical Application of CAMC - Long Bone X-Ray Image Stitching
    Heining, S. M.
    Wang, L.
    Navab, N.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 2323 - 2325
  • [38] Automatic Intra-operative Generation of Geometric Left Atrium/Pulmonary Vein Models from Rotational X-Ray Angiography
    Meyer, Carsten
    Manzke, Robert
    Peters, Jochen
    Ecabert, Olivier
    Kneser, Reinhard
    Reddy, Vivek Y.
    Chan, Raymond C.
    Weese, Juergen
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT II, PROCEEDINGS, 2008, 5242 : 61 - 69
  • [39] Anatomy based registration of CT-scan and x-ray fluoroscopy data for intra-operative guidance of a surgical robot
    Guziec, A
    Kazanzides, P
    Williamson, B
    Taylor, RH
    Lord, D
    MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 : 81 - 94
  • [40] Acute and chronic complications associated with x-ray intra-operative radiation: The first 1000 patients from a single center
    Epstein, Melinda
    Khan, Sadia
    Chen, Peter
    Kim, Brian
    Lin, Kevin
    Snyder, Lincoln
    Coleman, Colleen
    Lopez, January
    Guerra, Lisa
    Mackintosh, Ralph
    Silverstein, Melvin
    ANNALS OF SURGICAL ONCOLOGY, 2018, 25 : 588 - 589