Parallax-free intra-operative X-ray image stitching

被引:33
|
作者
Wang, Lejing [1 ]
Traub, Joerg [1 ]
Weidert, Simon [2 ]
Heining, Sandro Michael [2 ]
Euler, Ekkehard [2 ]
Navab, Nassir [1 ]
机构
[1] Tech Univ Munich, Fak Informat, D-85748 Garching, Germany
[2] Ludwig Maximilians Univ Munchen, Klinikum Innenstadt, Dept Trauma Surg, Munich, Germany
关键词
X-ray image stitching; Camera Augmented Mobile C-arm; Computer aided surgery; FRACTURES; MALALIGNMENT; RADIOGRAPHY; ANGLE;
D O I
10.1016/j.media.2010.05.007
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We present a novel method to generate parallax-free panoramic X-ray images during surgery by enabling the mobile C-arm to rotate around its X-ray source center, relative to the patient's table. Rotating the mobile C-arm around its X-ray source center is impractical and sometimes impossible due to the mechanical design of mobile C-arm systems. In order to ensure that the C-arm motion is a relative pure rotation around its X-ray source center, we propose to move the table to compensate for the translational part of the motion based on C-arm pose estimation. For this we employ a visual marker pattern and a Camera Augmented Mobile C-arm system that is a standard mobile C-arm augmented by a video camera and mirror construction. We are able to produce a parallax-free panoramic X-ray image independent of the geometric configuration of imaged anatomical structures. Our method does not require a fronto-parallel setup or any overlap between the acquired X-ray images. This generated parallax-free panoramic Xray image preserves the linear perspective projection property. It also presents a negligible difference (below 2 pixels) in the overlapping area between two consecutive individual X-ray images and has a high visual quality. This promises suitability for intra-operative clinical applications in orthopedic and trauma surgery. The experiments on phantoms and ex-vivo bone structure demonstrate both the functionality and accuracy of the method. (C) 2010 Elsevier BM. All rights reserved.
引用
收藏
页码:674 / 686
页数:13
相关论文
共 50 条
  • [21] Trocar assisted distal shunt tube insertion with intra-operative X-Ray confirmation
    Osman, Mostafa
    Diraz, Ahmed
    Wild, Andrew
    BRITISH JOURNAL OF NEUROSURGERY, 2019, 33 (04) : 394 - 397
  • [22] Test results of the parallax-free X-ray area detector SD-1000 in the diffractometer CARD-7
    Zanevsky, YV
    Chernenko, SP
    Cheremukhina, GA
    Fateev, OV
    Kheiker, DM
    Andrianova, ME
    Sulianov, SN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 367 (1-3): : 76 - 78
  • [23] Fast parallax-free one-coordinate X-ray detector OD120 with the registration angle up to 360°
    Aulchenko, V.M.
    Bukin, M.A.
    Vasil'ev, A.V.
    Velikzhanin, Yu.S.
    Drozdetskij, A.A.
    Dubrovin, M.S.
    Skripkin, A.G.
    Titov, V.M.
    Tolochko, B.P.
    Sharafutdinov, M.R.
    Poverkhnost Rentgenovskie Sinkhronnye i Nejtronnye Issledovaniya, 2002, (11): : 13 - 18
  • [24] Fast parallax-free, one-coordinate X-ray detector OD120 with the registration angle up to 360°
    Aulchenko, VM
    Bukin, MA
    Drozdetsky, AA
    Dubrovin, MS
    Sharafutdinov, MR
    Titov, VM
    Tolochko, BP
    Vasiljev, AV
    Velikzhanin, YS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 470 (1-2): : 168 - 172
  • [25] Intra-operative volume imaging of the left atrium and pulmonary veins with rotational X-ray angiography
    Manzke, Robert
    Reddy, Vivek Y.
    Dalal, Sandeep
    Hanekamp, Annemarie
    Rasche, Volker
    Chan, Raymond C.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2006, PT 1, 2006, 4190 : 604 - 611
  • [26] The case for intra-operative X-ray in cochlear implantation: Four illustrative cases and literature review
    Yu, Cheryl
    Debs, Sarah
    Singh, Rhea
    Kastetter, Sean
    Pierre-Louis, Akilah
    Coelho, Daniel H.
    COCHLEAR IMPLANTS INTERNATIONAL, 2022, 23 (06) : 332 - 338
  • [27] 2D/3D registration of pre-operative CT images and intra-operative x-ray projections for image guided surgery
    Weese, J
    Penney, GP
    Buzug, TM
    Fassnacht, C
    Lorenz, C
    CAR '97 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1997, 1134 : 833 - 838
  • [28] Distortion correction and calibration of intra-operative spine X-ray images using a constrained DLT algorithm
    Bertelsen, A.
    Garin-Muga, A.
    Echeverria, M.
    Gomez, E.
    Borro, D.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2014, 38 (07) : 558 - 568
  • [29] Investigation of isotropic radiation of low energy X-ray intra-operative radiotherapy by MAGAT gel dosimeter
    Nezhad, Zahra Alyani
    Geraily, Ghazale
    Zohari, Shahin
    RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [30] 3D Global Estimation and Augmented Reality Visualization of Intra-operative X-ray Dose
    Rodas, Nicolas Loy
    Padoy, Nicolas
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2014, PT I, 2014, 8673 : 415 - 422