Comparison of visual function following implantation of Acrysof Natural intraocular lenses with conventional intraocular lenses

被引:27
|
作者
Landers, John [1 ]
Tan, Teng-Han [1 ]
Yuen, Joshua [1 ]
Liu, Henry [1 ]
机构
[1] Orana Eye Ctr, Dubbo, NSW 2830, Australia
来源
关键词
blue-blocking; colour vision; contrast sensitivity; intraocular lens;
D O I
10.1111/j.1442-9071.2006.01434.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Recently an intraocular lens (IOL) has been introduced which blocks blue light. As blocking blue light may be to the patient's detriment, this study was designed to evaluate visual function following implantation of a blue-blocking (Acrysof Natural) IOL. Patients were recruited for this non-randomized controlled interventional study, from those attending a private rural ophthalmology clinic for cataract surgery (n = 93). Only those who had previously had a conventional IOL implanted into one eye were offered an Acrysof Natural IOL for the second eye. Postoperatively patients underwent refracted Snellen visual acuity, contrast sensitivity using a CSV-1000E instrument and colour vision testing using a Farnsworth D-15 test, with a subset (n = 20) undergoing a Farnsworth-Munsell 100-Hue test. Results were then compared between eyes. Finally, a subset (n = 63) completed a survey designed to assess the subjective impact of the Acrysof Natural IOL. There were no statistically significant differences between eyes implanted with conventional IOLs compared with Acrysof Natural IOLs for visual acuity (t = 0.57; P = 0.57), contrast sensitivity (t = 0.43; P = 0.67 for 3 cycles per degree [cpd], t = 0.56; P = 0.58 for 6 cpd, t = 0.09; P = 0.93 for 12 cpd and t = 0.16; P = 0.87 for 18 cpd) or colour vision with the Farnsworth D-15 (chi(2) = 0.38; P = 0.55) or the Farnsworth-Munsell 100-Hue test t = 0.34; P = 0.74). Most subjects reported that they could not tell a difference between the two IOLs subjectively or that any difference experienced was not significant. Our sample did not show any significant differences between eyes implanted with conventional IOLs and the Acrysof Natural IOL. We would suggest that the Acrysof Natural IOL may be used without any significant difference in visual function.
引用
收藏
页码:152 / 159
页数:8
相关论文
共 50 条
  • [41] Comparison of the AcrySof IQ aspheric blue light filter and the AcrySof SA60AT intraocular lenses
    Mester, Ulrich
    Kaymak, Hakan
    JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (08) : 817 - 825
  • [42] Comparison of 6-month results of implantation of the 1CU accommodative intraocular lens with conventional intraocular lenses
    Küchle, M
    Seitz, B
    Langenbucher, A
    Gusek-Schneider, GC
    Martus, P
    Nguyen, NX
    OPHTHALMOLOGY, 2004, 111 (02) : 318 - 324
  • [43] Comparison of visual function with three intraocular lenses under different illumination conditions
    Haddi, I. Baoud Ould
    Cervantes, D. Flores
    Ramirez, E. Dorronzoro
    Sanchez, V. Blazquez
    Arias, C. Bonnin
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2025, 48 (03):
  • [44] Final clear corneal incision size for AcrySof intraocular lenses
    Moreno-Montañés, J
    Maldonado, MJ
    García-Layana, A
    Aliseda, D
    Munuera, JM
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (07): : 959 - 963
  • [45] UNWANTED OPTICAL-IMAGES WITH NARROW PROFILE INTRAOCULAR LENSES COMPARED WITH CONVENTIONAL INTRAOCULAR LENSES
    ARMSTRONG, TA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (05): : 578 - 581
  • [46] Comparison of visual outcomes between bilateral trifocal intraocular lenses and combined bifocal intraocular lenses with different near addition
    Ken Hayashi
    Tatsuhiko Sato
    Chizuka Igarashi
    Motoaki Yoshida
    Japanese Journal of Ophthalmology, 2019, 63 : 429 - 436
  • [47] Visual function in patients with yellow tinted intraocular lenses compared with vision in patients with non-tinted intraocular lenses
    Hayashi, K.
    Hayashi, H.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (08) : 1019 - 1023
  • [48] Comparison of visual outcomes between bilateral trifocal intraocular lenses and combined bifocal intraocular lenses with different near addition
    Hayashi, Ken
    Sato, Tatsuhiko
    Igarashi, Chizuka
    Yoshida, Motoaki
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2019, 63 (06) : 429 - 436
  • [49] Color perception with AcrySof Natural and AcrySof single-piece intraocular lenses under photopic and mesopic conditions
    Cionni, RJ
    Tsai, JH
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (02): : 236 - 242
  • [50] Comparison of ocular straylight after implantation of multifocal intraocular lenses
    Labuz, Grzegorz
    Reus, Nicolaas J.
    van den Berg, Thomas J. T. P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (04): : 618 - 625