Comparison of ocular straylight after implantation of multifocal intraocular lenses

被引:25
|
作者
Labuz, Grzegorz [1 ,4 ]
Reus, Nicolaas J. [1 ,2 ]
van den Berg, Thomas J. T. P. [3 ]
机构
[1] Rotterdam Ophthalm Inst, Rotterdam, Netherlands
[2] Amphia Hosp, Dept Ophthalmol, Breda, Netherlands
[3] Royal Netherlands Acad Arts & Sci, Netherlands Inst Neurosci, Amsterdam, Netherlands
[4] Univ Murcia, Fac Opt & Optometria, Murcia, Spain
来源
关键词
SURFACE LIGHT-SCATTERING; CATARACT-SURGERY; RETINAL STRAYLIGHT; RANDOMIZED-TRIAL; VISUAL FUNCTION; DONOR LENSES; OPACIFICATION; HISTORY; QUALITY; VISION;
D O I
10.1016/j.jcrs.2016.02.022
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A comprehensive review of the effect of multifocal intraocular lens (IOL) designs on postoperative ocular straylight was performed. Studies reporting straylight values obtained with the natural pupil using the C-Quant device after uneventful multifocal IOL implantation were included. The IOLs were categorized based on their material characteristics; that is, hydrophobicity and presence of colored chromophores. Age adjustment was achieved using the straylight age-dependency norm for pseudophakic eyes. This norm also served as a reference for comparing mean straylight levels of the various IOLs. The literature review identified 10 studies reporting 9 multifocal IOL designs. The hydrophilic IOLs showed less straylight than the hydrophobic IOLs by 0.08 log(s) (P = .001). Blue violet light filtering IOLs showed less straylight than standard IOLs by 0.04 log(s), which was not statistically significant (P = .32). Hydrophobicity was a factor that significantly affected straylight in multifocal IOLs. (C) 2016 ASCRS and ESCRS
引用
收藏
页码:618 / 625
页数:8
相关论文
共 50 条
  • [1] Ocular Straylight with Different Multifocal Contact Lenses
    Labuz, Grzegorz
    Lopez-Gil, Norberto
    van den Berg, Thomas J. T. P.
    Vargas-Martin, Fernando
    OPTOMETRY AND VISION SCIENCE, 2017, 94 (04) : 496 - 504
  • [2] Dissatisfaction after implantation of multifocal intraocular lenses
    Bonnet, Clemence
    Brezin, Antoine P.
    Monnet, Dominique
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [3] Dissatisfaction after implantation of multifocal intraocular lenses
    de Vries, Niels E.
    Webers, Carroll A. B.
    Touwslager, Wouter R. H.
    Bauer, Noel J. C.
    de Brabander, John
    Berendschot, Tos T.
    Nuijts, Rudy M. M. A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05): : 859 - 865
  • [4] Retinal straylight in patients with monofocal and multifocal intraocular lenses
    Cervino, Alejandro
    Hosking, Sarah L.
    Montes-Mico, Robert
    Alio, Jorge L.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03): : 441 - 446
  • [5] Autorefraction after implantation of diffractive multifocal intraocular lenses
    Bissen-Miyajima, Hiroko
    Minami, Keiichiro
    Yoshino, Mami
    Nishimura, Mariko
    Oki, Shinchi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04): : 553 - 556
  • [6] Comparison of visual outcomes and reading performance after bilateral implantation of multifocal intraocular lenses with bilateral monofocal intraocular lenses
    Özge Güngör Akkuş
    Ikbal Seza Petriçli
    International Ophthalmology, 2018, 38 : 1011 - 1019
  • [7] Comparison of visual outcomes and reading performance after bilateral implantation of multifocal intraocular lenses with bilateral monofocal intraocular lenses
    Akkus, Ozge Gungor
    Petricli, Ikbal Seza
    INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (03) : 1011 - 1019
  • [8] Stereoacuity after implantation of different designed multifocal intraocular lenses
    Schwarz, EC
    Walkow, T
    Waffenschmidt, E
    TRANSACTIONS OF THE IX INTERNATIONAL ORTHOPTIC CONGRESS, 1999, : 276 - 276
  • [9] Straylight Measurements in Two Different Apodized Diffractive Multifocal Intraocular Lenses
    Lapid-Gortzak, Ruth
    Labuz, Grzegorz
    van der Meulen, Ivanka J.
    van der Linden, Jan Willem
    Mourits, M. P.
    van den Berg, Tom J.
    JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (11) : 746 - 751
  • [10] Comparison of visual performance after implantation of 3 types of intraocular lenses: accommodative, multifocal, and monofocal
    Tan, Nian
    Zheng, Dengyi
    Ye, Jian
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2014, 24 (05) : 693 - 698