Comparison of visual function following implantation of Acrysof Natural intraocular lenses with conventional intraocular lenses

被引:27
|
作者
Landers, John [1 ]
Tan, Teng-Han [1 ]
Yuen, Joshua [1 ]
Liu, Henry [1 ]
机构
[1] Orana Eye Ctr, Dubbo, NSW 2830, Australia
来源
关键词
blue-blocking; colour vision; contrast sensitivity; intraocular lens;
D O I
10.1111/j.1442-9071.2006.01434.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Recently an intraocular lens (IOL) has been introduced which blocks blue light. As blocking blue light may be to the patient's detriment, this study was designed to evaluate visual function following implantation of a blue-blocking (Acrysof Natural) IOL. Patients were recruited for this non-randomized controlled interventional study, from those attending a private rural ophthalmology clinic for cataract surgery (n = 93). Only those who had previously had a conventional IOL implanted into one eye were offered an Acrysof Natural IOL for the second eye. Postoperatively patients underwent refracted Snellen visual acuity, contrast sensitivity using a CSV-1000E instrument and colour vision testing using a Farnsworth D-15 test, with a subset (n = 20) undergoing a Farnsworth-Munsell 100-Hue test. Results were then compared between eyes. Finally, a subset (n = 63) completed a survey designed to assess the subjective impact of the Acrysof Natural IOL. There were no statistically significant differences between eyes implanted with conventional IOLs compared with Acrysof Natural IOLs for visual acuity (t = 0.57; P = 0.57), contrast sensitivity (t = 0.43; P = 0.67 for 3 cycles per degree [cpd], t = 0.56; P = 0.58 for 6 cpd, t = 0.09; P = 0.93 for 12 cpd and t = 0.16; P = 0.87 for 18 cpd) or colour vision with the Farnsworth D-15 (chi(2) = 0.38; P = 0.55) or the Farnsworth-Munsell 100-Hue test t = 0.34; P = 0.74). Most subjects reported that they could not tell a difference between the two IOLs subjectively or that any difference experienced was not significant. Our sample did not show any significant differences between eyes implanted with conventional IOLs and the Acrysof Natural IOL. We would suggest that the Acrysof Natural IOL may be used without any significant difference in visual function.
引用
收藏
页码:152 / 159
页数:8
相关论文
共 50 条
  • [31] Forward Light Scatter, Modulation Transfer Function and Image Quality Measurements for AcrySof Natural Intraocular Lenses
    Das, Kamal
    Schwiegerling, Jim
    Karakelle, Mutlu
    Stover, John
    Ong, Marcia
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [32] Changes in visual performance after implantation of different intraocular lenses
    Li, Bo-Wen
    Huang, Hao
    Huang, Man-Sha
    Guo, Shuang-Lin
    Gao, Lu
    Zeng, Yu-Ying
    Cheng, Lu
    Yao, Si-Yang
    Lin, Jian-Qiang
    Liu, Lin
    Yang, Ye
    Lu, Xiao-Ming
    Cheng, Hao
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2024, 17 (07) : 1273 - 1282
  • [33] Preoperative Factors Affecting Visual Acuity Following the Implantation of Diffractive Multifocal Intraocular Lenses
    Takabatake, Ryu
    Takahashi, Makiko
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (10) : 674 - +
  • [34] Sealed implantation of foldable intraocular lenses
    Nath, Dharmendra
    Blumenthal, Eytan Z.
    Sharma, Mohita
    Mimouni, Michael
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (05) : 555 - 558
  • [35] Implantation of intraocular lenses in the ciliary sulcus
    Schulze, S.
    Bertelmann, T.
    Sekundo, W.
    OPHTHALMOLOGE, 2014, 111 (04): : 305 - 309
  • [36] Secondary Implantation of Intraocular Lenses in Children
    Guo, Sugin
    Forbes, Brian J.
    Wilson, M. Edward
    JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2009, 46 (04) : 196 - 199
  • [37] INTRACAPSULAR IMPLANTATION OF MONOLITHIC INTRAOCULAR LENSES
    YASINSKAS, VP
    VARSHAVSKY, VL
    VESTNIK OFTALMOLOGII, 1988, (03) : 27 - 29
  • [38] IMPLANTATION OF INTRAOCULAR LENSES IN GLAUCOMA PATIENTS
    TRINKMANN, R
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1985, 187 (04) : 318 - 318