Comparison of a simple obstructive sleep apnea screening device with standard in-laboratory polysomnography

被引:4
|
作者
Assefa, Samson Z. [1 ]
Diaz-Abad, Montserrat [1 ]
Korotinsky, Arkady [1 ,2 ]
Tom, Sarah E. [3 ]
Scharf, Steven M. [1 ]
机构
[1] Univ Maryland, Div Pulm & Crit Care Med, Sleep Disorders Ctr, Sch Med, 100 N Greene St,2nd Floor, Baltimore, MD 21201 USA
[2] Vet Affairs Oxnard Clin, Oxnard, CA 93036 USA
[3] Univ Maryland, Pharmaceut Hlth Serv, Res Dept, Sch Pharm, Baltimore, MD 21201 USA
关键词
Obstructive sleep apnea; Sleep apnea screening; Home apnea screening; ApneaStrip; Home sleep testing; COST-EFFECTIVENESS; DIAGNOSIS; HOME; EPIDEMIOLOGY; CURVE; AREA;
D O I
10.1007/s11325-015-1234-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Obstructive sleep apnea (OSA) is a common underdiagnosed sleep disorder. Various strategies have been employed to easily screen for OSA. The ApneaStripA (R) (AS - S.L.P. Ltd, Tel Aviv, Israel) is an FDA approved OSA screening device applied to the upper lip at home. We evaluated the performance of this device against simultaneous in-laboratory polysomnography (PSG) in a group of well-characterized OSA patients. Diagnostic PSG was performed in 56 patients (29 M, 37 F; age 48.9 +/- 14.6 years; body mass index [BMI] 37.5 +/- 9.0 kg/m(2); apnea-hypopnea index-events/h-[AHI] 32.8 +/- 22.9). The AS was applied and positioned to detect nasal and oral airflow. The AS gives a "positive" result for AHI a parts per thousand yenaEuro parts per thousand 15. We examined the sensitivity and specificity of the AS against three thresholds derived from PSG: AHI a parts per thousand yenaEuro parts per thousand 5, AHI a parts per thousand yenaEuro parts per thousand 15 (company recommendation), and AHI a parts per thousand yenaEuro parts per thousand 30. For PSG AHI a parts per thousand yenaEuro parts per thousand 15, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the AS were 80, 54.5, 87.8, and 40 %, respectively. For PSG AHI a parts per thousand yenaEuro parts per thousand 5, the values were 75.1, 66.7, 97.1, and 13.3 %, respectively. For PSG AHI a parts per thousand yenaEuro parts per thousand 30, the values were 86.9, 36.2, 48.8, and 80 %, respectively. There were no significant modifying effects of age, BMI, gender, hypertension, diabetes, lung disease, and heart disease. The AS has a high sensitivity for detection of OSA with AHI a parts per thousand yenaEuro parts per thousand 15, but only modest specificity. The AS could be a useful component of an OSA screening program; however, negative results should be interpreted cautiously.
引用
收藏
页码:537 / 541
页数:5
相关论文
共 50 条
  • [41] Underestimation of Sleep Apnea With Home Sleep Apnea Testing Compared to In-Laboratory Sleep Testing
    Setty, Arveity R.
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2017, 13 (04): : 531 - 532
  • [42] Validation of the Apnea Risk Evaluation System (ARES) Device Against Laboratory Polysomnography in Pregnant Women at Risk for Obstructive Sleep Apnea Syndrome
    Sharkey, Katherine M.
    Waters, Kelly
    Millman, Richard P.
    Moore, Robin
    Martin, Susan M.
    Bourjeily, Ghada
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2014, 10 (05): : 497 - 502
  • [43] Obstructive sleep apnea on Polysomnography in patients with Parkinsonism
    Bittinger, LJ
    McNear, KK
    Khan, F
    Loffer, R
    Mohan, K
    SLEEP, 2005, 28 : A283 - A283
  • [44] Sleep deprivation worsens obstructive sleep apnea - Comparison between diurnal and nocturnal polysomnography
    Persson, HE
    Svanborg, E
    CHEST, 1996, 109 (03) : 645 - 650
  • [45] Diagnostic aspects of polysomnography in obstructive sleep apnea
    Lee, Seung Hoon
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2012, 55 (02): : 138 - 145
  • [46] A comparison of polysomnography and a portable home sleep study in the diagnosis of obstructive sleep apnea syndrome
    Su, S
    Baroody, FM
    Kohrman, M
    Suskind, D
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2004, 131 (06) : 844 - 850
  • [47] Diagnosis of obstructive sleep apnea - Alternatives to polysomnography
    Collop, Nancy A.
    CHEST, 2006, 130 (05) : 1625 - 1626
  • [48] Influence of the device used for obstructive sleep apnea diagnosis on body position: a comparison between polysomnography and portable monitor
    André A. F. Mello
    Giovanna D´Angelo
    Ronaldo B. Santos
    Isabela Bensenor
    Paulo A. Lotufo
    Geraldo Lorenzi-Filho
    Luciano F. Drager
    Pedro R. Genta
    Sleep and Breathing, 2023, 27 : 887 - 891
  • [49] Using a wrist-worn device based on peripheral arterial tonometry to diagnose obstructive sleep apnea: In-laboratory and ambulatory validation
    Pittman, SD
    Ayas, NT
    MacDonald, MM
    Malhotra, A
    Fogel, RB
    White, DP
    SLEEP, 2004, 27 (05) : 923 - 933
  • [50] Influence of the device used for obstructive sleep apnea diagnosis on body position: a comparison between polysomnography and portable monitor
    Mello, Andre A. F.
    D'Angelo, Giovanna
    Santos, Ronaldo B.
    Bensenor, Isabela
    Lotufo, Paulo A.
    Lorenzi-Filho, Geraldo
    Drager, Luciano F.
    Genta, Pedro R.
    SLEEP AND BREATHING, 2023, 27 (03) : 887 - 891