Comparison of a simple obstructive sleep apnea screening device with standard in-laboratory polysomnography

被引:4
|
作者
Assefa, Samson Z. [1 ]
Diaz-Abad, Montserrat [1 ]
Korotinsky, Arkady [1 ,2 ]
Tom, Sarah E. [3 ]
Scharf, Steven M. [1 ]
机构
[1] Univ Maryland, Div Pulm & Crit Care Med, Sleep Disorders Ctr, Sch Med, 100 N Greene St,2nd Floor, Baltimore, MD 21201 USA
[2] Vet Affairs Oxnard Clin, Oxnard, CA 93036 USA
[3] Univ Maryland, Pharmaceut Hlth Serv, Res Dept, Sch Pharm, Baltimore, MD 21201 USA
关键词
Obstructive sleep apnea; Sleep apnea screening; Home apnea screening; ApneaStrip; Home sleep testing; COST-EFFECTIVENESS; DIAGNOSIS; HOME; EPIDEMIOLOGY; CURVE; AREA;
D O I
10.1007/s11325-015-1234-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Obstructive sleep apnea (OSA) is a common underdiagnosed sleep disorder. Various strategies have been employed to easily screen for OSA. The ApneaStripA (R) (AS - S.L.P. Ltd, Tel Aviv, Israel) is an FDA approved OSA screening device applied to the upper lip at home. We evaluated the performance of this device against simultaneous in-laboratory polysomnography (PSG) in a group of well-characterized OSA patients. Diagnostic PSG was performed in 56 patients (29 M, 37 F; age 48.9 +/- 14.6 years; body mass index [BMI] 37.5 +/- 9.0 kg/m(2); apnea-hypopnea index-events/h-[AHI] 32.8 +/- 22.9). The AS was applied and positioned to detect nasal and oral airflow. The AS gives a "positive" result for AHI a parts per thousand yenaEuro parts per thousand 15. We examined the sensitivity and specificity of the AS against three thresholds derived from PSG: AHI a parts per thousand yenaEuro parts per thousand 5, AHI a parts per thousand yenaEuro parts per thousand 15 (company recommendation), and AHI a parts per thousand yenaEuro parts per thousand 30. For PSG AHI a parts per thousand yenaEuro parts per thousand 15, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the AS were 80, 54.5, 87.8, and 40 %, respectively. For PSG AHI a parts per thousand yenaEuro parts per thousand 5, the values were 75.1, 66.7, 97.1, and 13.3 %, respectively. For PSG AHI a parts per thousand yenaEuro parts per thousand 30, the values were 86.9, 36.2, 48.8, and 80 %, respectively. There were no significant modifying effects of age, BMI, gender, hypertension, diabetes, lung disease, and heart disease. The AS has a high sensitivity for detection of OSA with AHI a parts per thousand yenaEuro parts per thousand 15, but only modest specificity. The AS could be a useful component of an OSA screening program; however, negative results should be interpreted cautiously.
引用
收藏
页码:537 / 541
页数:5
相关论文
共 50 条
  • [21] Continuous positive airway pressure device-based automated detection of obstructive sleep apnea compared to standard laboratory polysomnography
    Bharati Prasad
    David W. Carley
    James J. Herdegen
    Sleep and Breathing, 2010, 14 : 101 - 107
  • [22] A comparison of polysomnography and the WatchPAT in the diagnosis of obstructive sleep apnea
    Pang, Kenny P.
    Gourin, Christine G.
    Terris, David J.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2007, 137 (04) : 665 - 668
  • [23] Impact of sleep chronotype on in-laboratory polysomnography parameters
    Colelli, David R.
    Dela Cruz, Gio R.
    Kendzerska, Tetyana
    Murray, Brian J.
    Boulos, Mark I.
    JOURNAL OF SLEEP RESEARCH, 2023, 32 (05)
  • [24] Screening for obstructive sleep apnea in the memory clinic: A comparison of questionnaires, pulse oximetry, and polysomnography
    Lam, Aaron
    D'Rozario, Angela L.
    Kong, Shawn
    Ireland, Catriona
    Mowszowski, Loren
    Lamonica, Haley M.
    Phillips, Craig L.
    Hoyos, Camilla M.
    Grunstein, Ronald R.
    Naismith, Sharon L.
    JOURNAL OF ALZHEIMERS DISEASE, 2025, 103 (01) : 218 - 229
  • [25] Efficacy and safety of single-use suvorexant for insomnia during in-laboratory polysomnography in patients with obstructive sleep apnea: A feasibility study
    Matsumura, Takuma
    Terada, Jiro
    Kinoshita, Taku
    Sakurai, Yoriko
    Yahaba, Misuzu
    Sakao, Seiichiro
    Yoshimura, Chikara
    Tatsumi, Koichiro
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [26] The effect of in-laboratory polysomnography on sleep and objective daytime sleepiness
    Kingshott, RN
    Douglas, NJ
    SLEEP, 2000, 23 (08) : 1109 - 1113
  • [27] Potential Underestimation of Sleep Apnea Severity by At-Home Kits: Rescoring In-Laboratory Polysomnography Without Sleep Staging
    Bianchi, Matt T.
    Goparaju, Balaji
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2017, 13 (04): : 551 - 555
  • [28] Evaluation Of Obstructive Sleep Apnea Syndrome Predictors For Screening To Respiratory Polysomnography
    Faria, A. C.
    Chibante, F. O.
    Silva, J. A.
    Rufino, R. L.
    Costa, C. H.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [29] Measuring Sleep Stages and Screening for Obstructive Sleep Apnea with a Wearable Multi-Sensor System in Comparison to Polysomnography
    Zhou, Shuang-Jiang
    Yang, Rui
    Wang, Lei-Lei
    Qi, Meng
    Yuan, Xiao-Fei
    Wang, Ting-Ting
    Song, Tian-He
    Zhuang, Yun-Yue
    Li, Hong -Juan
    Tan, Yun-Long
    Wang, Xue
    Chen, Jing-Xu
    NATURE AND SCIENCE OF SLEEP, 2023, 15 : 353 - 362
  • [30] Correlation of Therapeutic Pressure Between Home Automatic Positive Airway Pressure and In-laboratory Polysomnography Manual Titration in Patients With Obstructive Sleep Apnea
    Saiphoklang, N.
    Pugongchai, A.
    Leelasittikul, K.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207