Comparison of a simple obstructive sleep apnea screening device with standard in-laboratory polysomnography

被引:4
|
作者
Assefa, Samson Z. [1 ]
Diaz-Abad, Montserrat [1 ]
Korotinsky, Arkady [1 ,2 ]
Tom, Sarah E. [3 ]
Scharf, Steven M. [1 ]
机构
[1] Univ Maryland, Div Pulm & Crit Care Med, Sleep Disorders Ctr, Sch Med, 100 N Greene St,2nd Floor, Baltimore, MD 21201 USA
[2] Vet Affairs Oxnard Clin, Oxnard, CA 93036 USA
[3] Univ Maryland, Pharmaceut Hlth Serv, Res Dept, Sch Pharm, Baltimore, MD 21201 USA
关键词
Obstructive sleep apnea; Sleep apnea screening; Home apnea screening; ApneaStrip; Home sleep testing; COST-EFFECTIVENESS; DIAGNOSIS; HOME; EPIDEMIOLOGY; CURVE; AREA;
D O I
10.1007/s11325-015-1234-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Obstructive sleep apnea (OSA) is a common underdiagnosed sleep disorder. Various strategies have been employed to easily screen for OSA. The ApneaStripA (R) (AS - S.L.P. Ltd, Tel Aviv, Israel) is an FDA approved OSA screening device applied to the upper lip at home. We evaluated the performance of this device against simultaneous in-laboratory polysomnography (PSG) in a group of well-characterized OSA patients. Diagnostic PSG was performed in 56 patients (29 M, 37 F; age 48.9 +/- 14.6 years; body mass index [BMI] 37.5 +/- 9.0 kg/m(2); apnea-hypopnea index-events/h-[AHI] 32.8 +/- 22.9). The AS was applied and positioned to detect nasal and oral airflow. The AS gives a "positive" result for AHI a parts per thousand yenaEuro parts per thousand 15. We examined the sensitivity and specificity of the AS against three thresholds derived from PSG: AHI a parts per thousand yenaEuro parts per thousand 5, AHI a parts per thousand yenaEuro parts per thousand 15 (company recommendation), and AHI a parts per thousand yenaEuro parts per thousand 30. For PSG AHI a parts per thousand yenaEuro parts per thousand 15, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the AS were 80, 54.5, 87.8, and 40 %, respectively. For PSG AHI a parts per thousand yenaEuro parts per thousand 5, the values were 75.1, 66.7, 97.1, and 13.3 %, respectively. For PSG AHI a parts per thousand yenaEuro parts per thousand 30, the values were 86.9, 36.2, 48.8, and 80 %, respectively. There were no significant modifying effects of age, BMI, gender, hypertension, diabetes, lung disease, and heart disease. The AS has a high sensitivity for detection of OSA with AHI a parts per thousand yenaEuro parts per thousand 15, but only modest specificity. The AS could be a useful component of an OSA screening program; however, negative results should be interpreted cautiously.
引用
收藏
页码:537 / 541
页数:5
相关论文
共 50 条
  • [31] Laboratory Polysomnography or Limited-Channel Sleep Studies for Obstructive Sleep Apnea Response
    Chai-Coetzer, Ching Li
    McArdle, Nigel
    McEvoy, R. Doug
    ANNALS OF INTERNAL MEDICINE, 2017, 167 (07) : 521 - 522
  • [32] UTILITY OF A RAPID SLEEP SCREENING QUESTIONNAIRE FOR PREDICTION OF OBSTRUCTIVE SLEEP APNEA DIAGNOSED BY POLYSOMNOGRAPHY
    Glidewell, R. N.
    Roby, E.
    Orr, W.
    SLEEP, 2011, 34 : A326 - A326
  • [33] A COMPARISON OF A WRIST WORN PORTABLE DEVICE (WATCHPAT)™ WITH IN-LAB POLYSOMNOGRAPHY FOR THE DIAGNOSIS OF OBSTRUCTIVE SLEEP APNEA
    Mittal, S.
    Suri, T. M.
    Hadda, V.
    Madan, K.
    Mohan, A.
    Pb, S.
    Tiwari, P.
    Guleria, R.
    SLEEP MEDICINE, 2019, 64 : S259 - S260
  • [34] Efficacy and cost savings of ambulatory versus in-laboratory obstructive sleep apnea diagnosis and treatment
    Townsend, D
    Sharma, A
    Freiberg, M
    Miller, J
    Brauer, E
    Scattarelli, D
    Sohl-Kreiger, R
    McEiver, J
    Eiken, T
    Lorentzen, T
    SLEEP, 2005, 28 : A188 - A188
  • [35] Treatment of obstructive sleep apnea with a simple CPAP device
    Qiu, Zhi-Hui
    Liang, Shan-Feng
    Deng, Xiao-Bin
    Wei, Qi-Shan
    Luo, Ying-Mei
    Wang, Lu
    Wu, Ying-Xin
    Steier, Joerg
    McEvoy, R. D.
    Luo, Yuan-Ming
    SLEEP AND BREATHING, 2023, 27 (06) : 2351 - 2359
  • [36] Treatment of obstructive sleep apnea with a simple CPAP device
    Zhi-Hui Qiu
    Shan-Feng Liang
    Xiao-Bin Deng
    Qi-Shan Wei
    Ying-Mei Luo
    Lu Wang
    Ying-Xin Wu
    Joerg Steier
    R. D. McEvoy
    Yuan-Ming Luo
    Sleep and Breathing, 2023, 27 : 2351 - 2359
  • [37] Is the OSA-18 predictive of obstructive sleep apnea: Comparison to polysomnography
    Ishman, Stacey L.
    Yang, Christina J.
    Cohen, Aliza P.
    Benke, James R.
    Meinzen-Derr, Jareen K.
    Anderson, Rebecca M.
    Madden, Marie E.
    Tabangin, Meredith E.
    LARYNGOSCOPE, 2015, 125 (06): : 1491 - 1495
  • [38] Computed Tomography Characterization and Comparison With Polysomnography for Obstructive Sleep Apnea Evaluation
    Chousangsuntorn, Khaisang
    Bhongmakapat, Thongchai
    Apirakkittikul, Navarat
    Sungkarat, Witaya
    Supakul, Nucharin
    Laothamatas, Jiraporn
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2018, 76 (04) : 854 - 872
  • [39] Comparative study of the SleepImage ring device and polysomnography for diagnosing obstructive sleep apnea
    Lu, Mi
    Brenzinger, Lisa
    Rosenblum, Lisa
    Salanitro, Matthew
    Fietze, Ingo
    Glos, Martin
    Fico, Giuseppe
    Penzel, Thomas
    BIOMEDICAL ENGINEERING LETTERS, 2023, 13 (03) : 343 - 352
  • [40] Comparative study of the SleepImage ring device and polysomnography for diagnosing obstructive sleep apnea
    Mi Lu
    Lisa Brenzinger
    Lisa Rosenblum
    Matthew Salanitro
    Ingo Fietze
    Martin Glos
    Giuseppe Fico
    Thomas Penzel
    Biomedical Engineering Letters, 2023, 13 : 343 - 352