Reflections on beam configuration optimization for intensity-modulated proton therapy

被引:6
|
作者
Cao, Wenhua [1 ]
Rocha, Humberto [2 ,3 ]
Mohan, Radhe [1 ]
Lim, Gino [4 ]
Goudarzi, Hadis M. [4 ]
Ferreira, Brigida C. [3 ,5 ]
Dias, Joana M. [2 ,3 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Coimbra, Fac Econ, CeBER, Coimbra, Portugal
[3] Univ Coimbra, INESC Coimbra, Coimbra, Portugal
[4] Univ Houston, Dept Ind Engn, Houston, TX 77204 USA
[5] Univ Lisbon, Inst Biophys & Biomed Engn, Fac Sci, Lisbon, Portugal
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2022年 / 67卷 / 13期
基金
美国国家卫生研究院;
关键词
beam angle optimization (BAO); proton therapy; IMPT; RBE; robustness; RELATIVE BIOLOGICAL EFFECTIVENESS; RADIATION-INDUCED LYMPHOPENIA; CANCER-INSTITUTE WORKSHOP; LINEAR-ENERGY-TRANSFER; CELL LUNG-CANCER; ANGLE OPTIMIZATION; ROBUST OPTIMIZATION; ORIENTATION OPTIMIZATION; TREATMENT UNCERTAINTIES; EYE-VIEW;
D O I
10.1088/1361-6560/ac6fac
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Presumably, intensity-modulated proton radiotherapy (IMPT) is the most powerful form of proton radiotherapy. In the current state of the art, IMPT beam configurations (i.e. the number of beams and their directions) are, in general, chosen subjectively based on prior experience and practicality. Beam configuration optimization (BCO) for IMPT could, in theory, significantly enhance IMPT's therapeutic potential. However, BCO is complex and highly computer resource-intensive. Some algorithms for BCO have been developed for intensity-modulated photon therapy (IMRT). They are rarely used clinically mainly because the large number of beams typically employed in IMRT renders BCO essentially unnecessary. Moreover, in the newer form of IMRT, volumetric modulated arc therapy, there are no individual static beams. BCO is of greater importance for IMPT because it typically employs a very small number of beams (2-4) and, when the number of beams is small, BCO is critical for improving plan quality. However, the unique properties and requirements of protons, particularly in IMPT, make BCO challenging. Protons are more sensitive than photons to anatomic changes, exhibit variable relative biological effectiveness along their paths, and, as recently discovered, may spare the immune system. Such factors must be considered in IMPT BCO, though doing so would make BCO more resource intensive and make it more challenging to extend BCO algorithms developed for IMRT to IMPT. A limited amount of research in IMPT BCO has been conducted; however, considerable additional work is needed for its further development to make it truly effective and computationally practical. This article aims to provide a review of existing BCO algorithms, most of which were developed for IMRT, and addresses important requirements specific to BCO for IMPT optimization that necessitate the modification of existing approaches or the development of new effective and efficient ones.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Robust Beam Orientation Optimization for Intensity-Modulated Proton Therapy
    Gu, W.
    Neph, R.
    Ruan, D.
    Zou, J.
    Dong, L.
    Sheng, K.
    MEDICAL PHYSICS, 2019, 46 (06) : E257 - E258
  • [2] Robust beam orientation optimization for intensity-modulated proton therapy
    Gu, Wenbo
    Neph, Ryan
    Ruan, Dan
    Zou, Wei
    Dong, Lei
    Sheng, Ke
    MEDICAL PHYSICS, 2019, 46 (08) : 3356 - 3370
  • [3] Fraction-variant beam orientation optimization for intensity-modulated proton therapy
    Gu, Wenbo
    O'Connor, Daniel
    Ruan, Dan
    Zou, Wei
    Dong, Lei
    Sheng, Ke
    MEDICAL PHYSICS, 2020, 47 (09) : 3826 - 3834
  • [4] Proton energy optimization and reduction for intensity-modulated proton therapy
    Cao, Wenhua
    Lim, Gino
    Liao, Li
    Li, Yupeng
    Jiang, Shengpeng
    Li, Xiaoqiang
    Li, Heng
    Suzuki, Kazumichi
    Zhu, X. Ronald
    Gomez, Daniel
    Zhang, Xiaodong
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (21): : 6341 - 6354
  • [5] Biological Effectiveness-Integrated Beam Orientation Optimization for Intensity-Modulated Proton Therapy
    Gu, W.
    Ruan, D.
    Zou, J.
    Dong, L.
    Sheng, K.
    MEDICAL PHYSICS, 2020, 47 (06) : E452 - E452
  • [6] Linear energy transfer weighted beam orientation optimization for intensity-modulated proton therapy
    Gu, Wenbo
    Ruan, Dan
    Zou, Wei
    Dong, Lei
    Sheng, Ke
    MEDICAL PHYSICS, 2021, 48 (01) : 57 - 70
  • [7] High Fidelity Robust Optimization for Intensity-Modulated Proton Therapy
    Gu, W.
    Ruan, D.
    Zou, J.
    Dong, L.
    Sheng, K.
    MEDICAL PHYSICS, 2018, 45 (06) : E641 - E641
  • [8] Biological Based Robust Optimization for Intensity-Modulated Proton Therapy
    Bai, X.
    Lim, G.
    Grosshans, D.
    Mohan, R.
    Cao, W.
    MEDICAL PHYSICS, 2018, 45 (06) : E643 - E643
  • [9] Adaptive method for multicriteria optimization of intensity-modulated proton therapy
    Kamal-Sayed, Hisham
    Ma, J.
    Tseung, H.
    Abdel-Rehim, A.
    Herman, M. G.
    Beltran, C. J.
    MEDICAL PHYSICS, 2018, 45 (12) : 5643 - 5652
  • [10] Intensity-modulated proton therapy with a scanned beam: Study of the effects of the beam instability
    Trofimov, A
    Slopsema, R
    Bortfeld, T
    Kooy, H
    Flanz, J
    MEDICAL PHYSICS, 2004, 31 (06) : 1797 - 1798