A CORRELATION BETWEEN BONE (B), INSERTION TORQUE (IT), AND IMPLANT STABILITY (S): BITS SCORE

被引:37
|
作者
Herekar, Manisha [1 ]
Sethi, Megha [1 ]
Ahmad, Tousif [1 ]
Fernandes, Aquaviva Sebasteao
Patil, Viraj [1 ]
Kulkarni, Harish [2 ]
机构
[1] Maratha Mandals Nathajirao G Halgekar Inst Dent S, Dept Prosthodont, Belgaum, Karnataka, India
[2] Tatyasaheb Kore Dent Coll & Res Ctr, Dept Oral & Maxillofacial Surg, Warnanagar, Maharashtra, India
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2014年 / 112卷 / 04期
关键词
RESONANCE FREQUENCY-ANALYSIS; COMPUTERIZED-TOMOGRAPHY VALUES; BIOMECHANICAL ASPECTS; ENDOSSEOUS IMPLANTS; TITANIUM IMPLANTS; DENSITY; PLACEMENT;
D O I
10.1016/j.prosdent.2014.02.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Although criteria for assessing bone quality have been reported, an overall score that correlates bone quality with the primary stability and secondary stability of implants is not yet available. Purpose. The purpose of this article was to propose a scoring index that will establish a correlation among the bone density values from computed tomography, maximum insertion torque values, and resonance frequency analysis in different phases of implant treatment. Material and methods. In this study, 60 implant sites were evaluated to assess bone density (Hounsfield units), insertion torque values (Ncm), and primary stability and secondary stability (implant stability quotient values obtained by using resonance frequency analysis). On the basis of computed tomography data, the bone was classified as D1 to D4. The insertion torque was noted and classified into 2 groups, A and B. The implant stability quotient values obtained from resonance frequency analysis depicting primary stability and secondary stability were classified into 5 groups. The primary score noted was a result of the values obtained for the 3 parameters at the time of implant placement. The secondary score was obtained by considering the values of the bone density and resonance frequency analysis recorded at different time intervals. Results. Bone densities of D2, D3, and D4 were noted, dividing the bone type into 3 groups. The maximum torque noted in the study was 40 Ncm. The difference between various insertion torque values and bone types was found to be statistically nonsignificant. Higher mean implant stability quotient values were obtained for primary and secondary stability for the D2 bone than for D3 and D4 bone. When analyzed according to the time of insertion, the mean values increased at second stage surgery in all bone types. The difference in mean values among all bone types was found to be statistically significant (P<.001). A comparison of primary and secondary implant stability quotient values in all bone types did not find any statistical significance (P=.780). A score was recorded at the time of implant placement and at the time of second stage surgery, and the prosthetic treatment was planned accordingly. Conclusions. The score highlight the importance of considering the association of bone quality, insertion torque values, and stability as denoted by implant stability quotient throughout treatment. Based on the variation. in the score noted at recall visits, alterations in the treatment plan can be made with respect to the healing period and prosthetic design.
引用
收藏
页码:805 / 810
页数:6
相关论文
共 50 条
  • [1] The Correlation Between Immediate Implant Insertion Torque and Implant Stability Quotient
    Levin, Barry P.
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2016, 36 (06) : 833 - 840
  • [2] LIMITED EVIDENCE SUGGESTS NO CORRELATION BETWEEN IMPLANT INSERTION TORQUE AND IMPLANT SURVIVAL AND MARGINAL BONE LOSS
    Radi, Iman Abd-Elwahab
    Samy, Mohannad Alaa Eldin Yehya
    JOURNAL OF EVIDENCE-BASED DENTAL PRACTICE, 2023, 23 (02)
  • [3] Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis
    Falco, Antonello
    Berardini, Marco
    Trisi, Paolo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (04) : 824 - 830
  • [4] Correlation Between Dental Implant Insertion Torque and Mandibular Alveolar Bone Density in Osteopenic and Osteoporotic Subjects
    Chai, John
    Chau, Anson C. M.
    Chu, Frederick C. S.
    Chow, Tak W.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (04) : 888 - 893
  • [5] Correlation between Implant Geometry, Bone Density, and the Insertion Torque/Depth Integral: A Study on Bovine Ribs
    Di Stefano, Danilo Alessio
    Arosio, Paolo
    Perrotti, Vittoria
    Iezzi, Giovanna
    Scarano, Antonio
    Piattelli, Adriano
    DENTISTRY JOURNAL, 2019, 7 (01)
  • [6] Relation between insertion torque and bone–implant contact percentage: an artificial bone study
    Cheng Liu
    Ming-Tzu Tsai
    Heng-Li Huang
    Michael Yuan-Chien Chen
    Jui-Ting Hsu
    Kuo-Chih Su
    Chih-Han Chang
    Aaron Yu-Jen Wu
    Clinical Oral Investigations, 2012, 16 : 1679 - 1684
  • [7] Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design
    Baldi, Domenico
    Lombardi, Teresa
    Colombo, Jacopo
    Cervino, Gabriele
    Perinetti, Giuseppe
    Di Lenarda, Roberto
    Stacchi, Claudio
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [8] Implant Primary Stability Determined by Resonance Frequency Analysis: Correlation With Insertion Torque, Histologic Bone Volume, and Torsional Stability at 6 Weeks
    Makary, Christian
    Rebaudi, Alberto
    Sammartino, Gilberto
    Naaman, Nada
    IMPLANT DENTISTRY, 2012, 21 (06) : 474 - 480
  • [9] Correlation of Radiographic Fractal Analysis with Implant Insertion Torque in a Rabbit Trabecular Bone Model
    Veltri, Mario
    Ferrari, Marco
    Balleri, Piero
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (01) : 108 - 114
  • [10] Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test
    Bayarchimeg, Dorjpalam
    Namgoong, Hee
    Kim, Byung Kook
    Kim, Myung Duk
    Kim, Sungtae
    Kim, Tae-Il
    Seol, Yang Jo
    Lee, Yong Moo
    Ku, Young
    Rhyu, In-Chul
    Lee, Eun Hee
    Koo, Ki-Tae
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2013, 43 (01): : 30 - 36