Characterization of a 2D ionization chamber array for IMRT QA

被引:0
|
作者
Shtraus, N.
Curran, B.
Moran, J.
Litzenberg, D.
机构
[1] Tel Aviv Med Ctr & Sch Med, Tel Aviv, Israel
[2] Univ Michigan, Med Ctr, Ann Arbor, MI USA
关键词
D O I
10.1118/1.2761556
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background and Purpose: Measurement‐based methods of quality assurance (QA) for Intensity Modulated Radiotherapy (IMRT) fields often include individual field verification at a neutral gantry angle using film or other 2D detector in addition to a composite ionization chamber check. Unfortunately, film is time‐consuming to use. Diode systems are currently available but these arrays are limited in size and spacing of the diodes. This work characterizes a new 2D ionization chamber array (MatriXX, Scanditronix‐Wellhofer) that can be used for treatment verification at neutral and planned gantry angles. Material and methods: The 2D array consists of 1020 ion chambers, arranged in a 32×32 cm2 grid. Each chamber is separated by 7.62 mm center to center and has a volume of 0.08 cm3. Properties such as linearity, reproducibility, pressure dependence, homogeneity, and accuracy of the 2D array have been evaluated for 6 and 16MV beams at neutral and planned gantry angles. Results: The 2D array response was found to be linear with dose from 0–800 cGy. The 2D array readings were reproducible to within a SD of ±0.14%. Examination of the array's pressure dependence, homogeneity, sensitivity as a function of ion chamber location, and the interpolated dose showed accuracies of better than 0.3%. Absolute dose measurements were done with the array and a calibrated ion chamber. Agreement was better than 0.6%. TPR measurements were made and found to agree with commissioning data in our planning system (UMplan). Measurements done using a 2 × 2 cm2 field placed randomly around the array show a standard deviation of 0.21%. Delivery of IMRT plans using multiple gantry angles showed excellent agreement with calculated results. Conclusions: The 2D array offers an excellent solution to simplifying QA and saving time, particularly for IMRT pre‐treatment QA. The device can be used for both relative and absolute dose measurements. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2600 / 2600
页数:1
相关论文
共 50 条
  • [41] EPID-Based Patient Specific IMRT QA Is Accurate and Efficient Compared to Using Ionization Chamber Array Devices
    Qi, P.
    Cui, T.
    Verdecchia, K.
    Qiu, L.
    Xia, P.
    MEDICAL PHYSICS, 2018, 45 (06) : E277 - E277
  • [42] Measurement of Proton Beam Spot Size Using a 2D Ion Chamber Array for Daily QA
    Thorne, N.
    Kassaee, A.
    MEDICAL PHYSICS, 2016, 43 (06) : 3500 - 3500
  • [43] 2D IMRT QA passing rate dependency on coronal plane
    Panetta, Joseph V.
    Veltchev, Iavor
    Price, Robert A.
    Ma, C-M Charlie
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 110
  • [44] Development of 2D pixel array ionization chamber system for Flash Proton beam
    Jang, Y.
    Yang, T.
    Park, S.
    Kim, J.
    Jang, H.
    Kim, K.
    Kim, G.
    Choi, S.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1462 - S1462
  • [45] IMRT QA via MapCHECK a 2D diode detector system
    Cullip, T
    Chang, S
    MEDICAL PHYSICS, 2003, 30 (06) : 1351 - 1351
  • [46] Automatic Ionization Chamber Measurement Points Selection for IMRT Point Dose QA
    Yang, D.
    Goddu, S.
    Rangaraj, D.
    MEDICAL PHYSICS, 2010, 37 (06) : 3229 - +
  • [47] Characterization of cylindrical ionization chambers for patient specific IMRT QA
    Fraser, Danielle
    Parker, William
    Seuntjens, Jan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (04): : 241 - 251
  • [48] The Effects of Low Dose Regions On 3D IMRT QA Delivery Using a MatriXX 2D Array and MULTICUBE
    Fox, C.
    Sanford, R.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [49] The IMRT and VMAT QA Experience Using PTW 2D-ARRAY
    Hung, C.
    Liu, K.
    Chen, W.
    Lai, C.
    Chen, H.
    Liu, C.
    Huang, Y.
    Chen, M.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [50] IMRT total plan verification with the PTW ionization chamber array
    Rhein, B.
    Haering, P.
    Janisch, E.
    Klemm, S.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S190 - S190