Characterization of a 2D ionization chamber array for IMRT QA

被引:0
|
作者
Shtraus, N.
Curran, B.
Moran, J.
Litzenberg, D.
机构
[1] Tel Aviv Med Ctr & Sch Med, Tel Aviv, Israel
[2] Univ Michigan, Med Ctr, Ann Arbor, MI USA
关键词
D O I
10.1118/1.2761556
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background and Purpose: Measurement‐based methods of quality assurance (QA) for Intensity Modulated Radiotherapy (IMRT) fields often include individual field verification at a neutral gantry angle using film or other 2D detector in addition to a composite ionization chamber check. Unfortunately, film is time‐consuming to use. Diode systems are currently available but these arrays are limited in size and spacing of the diodes. This work characterizes a new 2D ionization chamber array (MatriXX, Scanditronix‐Wellhofer) that can be used for treatment verification at neutral and planned gantry angles. Material and methods: The 2D array consists of 1020 ion chambers, arranged in a 32×32 cm2 grid. Each chamber is separated by 7.62 mm center to center and has a volume of 0.08 cm3. Properties such as linearity, reproducibility, pressure dependence, homogeneity, and accuracy of the 2D array have been evaluated for 6 and 16MV beams at neutral and planned gantry angles. Results: The 2D array response was found to be linear with dose from 0–800 cGy. The 2D array readings were reproducible to within a SD of ±0.14%. Examination of the array's pressure dependence, homogeneity, sensitivity as a function of ion chamber location, and the interpolated dose showed accuracies of better than 0.3%. Absolute dose measurements were done with the array and a calibrated ion chamber. Agreement was better than 0.6%. TPR measurements were made and found to agree with commissioning data in our planning system (UMplan). Measurements done using a 2 × 2 cm2 field placed randomly around the array show a standard deviation of 0.21%. Delivery of IMRT plans using multiple gantry angles showed excellent agreement with calculated results. Conclusions: The 2D array offers an excellent solution to simplifying QA and saving time, particularly for IMRT pre‐treatment QA. The device can be used for both relative and absolute dose measurements. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2600 / 2600
页数:1
相关论文
共 50 条
  • [31] A 2D Ion Chamber Array Detector as a QA Device for Spot Scanning Proton Beams
    Arjomandy, B.
    Gillin, M.
    Zhu, X.
    Sahoo, N.
    Ciangaru, G.
    Bues, M.
    Poenisch, F.
    Ding, X.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [32] How to Improve the Dose Accuracy for Gantry Angle Dependent Patient Specific IMRT QA Using 2D Ion Chamber Array with Octavius Phantom
    Choi, D.
    Nookala, P.
    Patyal, B.
    MEDICAL PHYSICS, 2012, 39 (06) : 3725 - 3725
  • [33] Evaluation of a Planar Ion Chamber Array for Patient Specific IMRT QA
    Magnelli, A.
    Bloe, L.
    Gajdos, S.
    Djemil, T.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [34] Dosimetric verification and validation of conformal and IMRT treatments fields with an ionization chamber 2D-array
    Evangelina, Figueroa M.
    Gabriel, Resendiz G.
    Miguel, Perez P.
    MEDICAL PHYSICS, 2008, 1032 : 222 - 224
  • [35] Portal dosimetry for pretreatment verification of IMRT plan: a comparison with 2D ion chamber array
    Sharma, Dayananda Shamurailatpam
    Mhatre, Vaibav
    Heigrujam, Malhotra
    Talapatra, Kaustav
    Mallik, Suman
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (04): : 238 - 248
  • [36] A method to enhance 2D ion chamber array patient specific quality assurance for IMRT
    Diaz Moreno, Rogelio Manuel
    Venencia, Daniel
    Garrigo, Edgardo
    Pipman, Yakov
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (01) : 145 - 151
  • [37] A method to enhance 2D ion chamber array patient specific quality assurance for IMRT
    Rogelio Manuel Diaz Moreno
    Daniel Venencia
    Edgardo Garrigo
    Yakov Pipman
    Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 145 - 151
  • [38] Characterization of a 2D ion chamber array for the verification of radiotherapy treatments
    Spezi, E
    Angelini, AL
    Romani, F
    Ferri, A
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (14): : 3361 - 3373
  • [39] Liquid filled ionization chamber 2D-array for patient specific QA for stereotactic treatment at CyberKnife®
    Magaddino, V.
    Vallet, V.
    Patin, D.
    Schopfer, M.
    Moeckli, R.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 836 - 836
  • [40] Dosimetric characteristics of the novel 2D ionization chamber array OCTAVIUS Detector 1500
    Stelljes, T. S.
    Harmeyer, A.
    Reuter, J.
    Looe, H. K.
    Chofor, N.
    Harder, D.
    Poppe, B.
    MEDICAL PHYSICS, 2015, 42 (04) : 1528 - 1537