Characterization of a 2D ionization chamber array for IMRT QA

被引:0
|
作者
Shtraus, N.
Curran, B.
Moran, J.
Litzenberg, D.
机构
[1] Tel Aviv Med Ctr & Sch Med, Tel Aviv, Israel
[2] Univ Michigan, Med Ctr, Ann Arbor, MI USA
关键词
D O I
10.1118/1.2761556
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background and Purpose: Measurement‐based methods of quality assurance (QA) for Intensity Modulated Radiotherapy (IMRT) fields often include individual field verification at a neutral gantry angle using film or other 2D detector in addition to a composite ionization chamber check. Unfortunately, film is time‐consuming to use. Diode systems are currently available but these arrays are limited in size and spacing of the diodes. This work characterizes a new 2D ionization chamber array (MatriXX, Scanditronix‐Wellhofer) that can be used for treatment verification at neutral and planned gantry angles. Material and methods: The 2D array consists of 1020 ion chambers, arranged in a 32×32 cm2 grid. Each chamber is separated by 7.62 mm center to center and has a volume of 0.08 cm3. Properties such as linearity, reproducibility, pressure dependence, homogeneity, and accuracy of the 2D array have been evaluated for 6 and 16MV beams at neutral and planned gantry angles. Results: The 2D array response was found to be linear with dose from 0–800 cGy. The 2D array readings were reproducible to within a SD of ±0.14%. Examination of the array's pressure dependence, homogeneity, sensitivity as a function of ion chamber location, and the interpolated dose showed accuracies of better than 0.3%. Absolute dose measurements were done with the array and a calibrated ion chamber. Agreement was better than 0.6%. TPR measurements were made and found to agree with commissioning data in our planning system (UMplan). Measurements done using a 2 × 2 cm2 field placed randomly around the array show a standard deviation of 0.21%. Delivery of IMRT plans using multiple gantry angles showed excellent agreement with calculated results. Conclusions: The 2D array offers an excellent solution to simplifying QA and saving time, particularly for IMRT pre‐treatment QA. The device can be used for both relative and absolute dose measurements. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2600 / 2600
页数:1
相关论文
共 50 条
  • [21] A multiple acquisition sequence for IMRT verification with a 2D ion chamber array
    Spezi, Emiliano
    Angelini, Anna Lisa
    Ferri, Andrea
    MEDICAL DOSIMETRY, 2006, 31 (04) : 269 - 272
  • [22] MATRIX IONIZATION CHAMBER BASED DOSE RECONSTRUCTION FOR IMRT QA
    Korevaar, E.
    van Hulzen, A.
    Wauben, D.
    van der Hulst, P.
    Langendijk, H.
    van 't Veld, A.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S388 - S388
  • [23] Design of a QA method to characterize submillimeter-sized PBS beam properties using a 2D ionization chamber array
    Lin, Yuting
    Bentefour, Hassan
    Flanz, Jacob
    Kooy, Hanne
    Clasie, Benjamin
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (10):
  • [24] QA of a tomotherapy unit by means of a 2D ion chamber array and the octavius phantom
    Hambach, L.
    Clermont, C.
    Devillers, M.
    Van Esch, A.
    Huyskens, D.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S82 - S82
  • [25] Gantry-Angle Dependence of a 2D Ion Chamber Array for IMAT QA
    O'Daniel, J.
    Kishore, M.
    Das, S.
    Wu, Qj
    Yoo, S.
    Yin, F.
    MEDICAL PHYSICS, 2010, 37 (06) : 3237 - +
  • [26] Determination of Proper Measurement Plane for 2D IMRT QA
    Panetta, J.
    Veltchev, I.
    Price, R.
    Ma, C.
    MEDICAL PHYSICS, 2019, 46 (06) : E607 - E607
  • [27] Qualification of a 2D Ionization Chamber Array for Beam Steering and Profile Measurement
    Gao, S.
    Balter, P.
    Rose, M.
    Simon, W.
    MEDICAL PHYSICS, 2015, 42 (06) : 3484 - 3485
  • [28] VMAT Monthly Quality Assurance Using a 2D Ionization Chamber Array
    Myers, P.
    Buckey, C.
    Mihailidis, D.
    Mavroidis, P.
    Esquivel, C.
    Gutierrez, A.
    Papanikolaou, N.
    Stathakis, S.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [29] Investigating ion recombination effects in a liquid-filled ionization chamber array used for IMRT QA measurements
    Knill, Cory
    Snyder, Michael
    Rakowski, Joseph T.
    Zhuang, Ling
    Matuszak, Martha
    Burmeister, Jay
    MEDICAL PHYSICS, 2016, 43 (05) : 2476 - 2484
  • [30] Patient-specific QA for CyberKnife plans using 2D ion chamber array
    Adamczyk, S.
    Skrobala, A.
    Adamczyk, M.
    Pawalowski, B.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S171 - S171