摘要
In brachytherapy cancer treatments, methods for Calculation of dose delivered to tumours and organs have been continuously improving. Monte Carlo methods are an important tool in dose calculation for brachytherapy cancer treatments, where the exposition to the source planning aims at the maximization of dose deposition in the target volume, while minimizing the deposition in healthy tissues. The use of interstitial brachytherapy sources follows the recommendations of AAPM REPORT No. 51. The present work is based on Monte Carlo simulations with the GEANT4 toolkit of the dose quantities recommended by that report. An Iridium-192 Buchler HDR source was simulated and the geometry of dose deposition in media and energy spectra have been obtained. Calculations also include the Dose Rate Constant Lambda, the Geometry Factor G(r,theta), the Anisotropy Function F(r,theta) and the Radial Dose Function g(r,theta).
引用
收藏
页码:544 / +
页数:2
相关论文
共 50 条
  • [1] MONTE CARLO SIMULATION OF AN Ir-192 BRACHYTHERAPY SOURCE SPECTRA, GEOMETRY AND ANYSOTROPY FACTORS USING GEANT4 CODE
    Oliveira Fonseca Rodrigues, Sane Simone
    Begalli, Marcia
    de Queiroz Filho, Pedro Pacheco
    Santos, Denison de Souza
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 132 - +
  • [2] Simulation of Ir-192 Source Functions with Geant4 Monte Carlo (MC) Methods
    Walke, M.
    Hass, P.
    Senz, S.
    Scheermann, J.
    Gademann, G.
    Ricke, J.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 : S103 - S103
  • [3] SIMULATION OF THE NEUTRON SPECTRA EVOLUTION WITH GEANT4 MONTE CARLO CODE
    Smolyar, V. P.
    Mileva, A. O.
    Tarasov, V. O.
    Neboha, H. H.
    Rusov, V. D.
    JOURNAL OF PHYSICAL STUDIES, 2021, 25 (02):
  • [4] Monte Carlo characterization of the GammaMed HDR Plus Ir-192 brachytherapy source
    Reyes, E.
    Sosa, M.
    Gil-Villegas, A.
    Monzon, E.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2016, 2 (01):
  • [5] Erratum to: Simulation of Electron Trajectories in the Multicusp Ion Source Using Geant4 Monte Carlo Code
    Fatemeh Khodadadi Azadboni
    Mahmood Sedaghatizade
    Journal of Fusion Energy, 2010, 29 : 305 - 305
  • [6] A Monte Carlo study on dose distribution evaluation of Flexisource Ir-192 brachytherapy source
    Alizadeh, Majid
    Ghorbani, Mandi
    Haghparast, Abbas
    Zare, Naser
    Moghaddas, Toktam Ahmadi
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2015, 20 (03) : 204 - 209
  • [7] A GEANT4 Monte-Carlo simulation code for precision β spectroscopy
    Wauters, F.
    Kraev, I.
    Zakoucky, D.
    Beck, M.
    Golovko, V. V.
    Kozlov, V. Yu.
    Phalet, T.
    Tandecki, M.
    Traykov, E.
    Van Gorp, S.
    Severijns, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 609 (2-3): : 156 - 164
  • [8] The Design of a Novel Direction Modulated Brachytherapy (DMBT) Vaginal Cylinder Using GEANT4 Monte Carlo Simulation Code
    Meftahi, M.
    Song, W.
    MEDICAL PHYSICS, 2020, 47 (06) : E857 - E858
  • [9] Monte Carlo simulation of MOSFET dosimeter for electron backscatter using the GEANT4 code
    Chow, James C. L.
    Leung, Michael K. K.
    MEDICAL PHYSICS, 2008, 35 (06) : 2383 - 2390
  • [10] Monte Carlo study of a bunker used for HDR Ir-192 brachytherapy
    Ballester, F
    Granero, D
    Pérez-Calatayud, J
    Puchades, V
    Casal, E
    Crispin, V
    Cases, R
    Agramunt, S
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S242 - S242