Simplified clinical quality assurance for helical tomotherapy

被引:0
|
作者
Grant, W.
McGary, J.
Childress, N.
CravenS, R.
Krumbach, T.
Olivera, G.
机构
[1] Baylor Coll Med, Methodist Hosp, Houston, TX 77030 USA
[2] Tomotherapy Inc, Madison, WI USA
[3] Med Radiat Res Ctr, Madison, WI USA
关键词
D O I
10.1118/1.2761395
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate a Web‐based Quality Assurance tool for maintaining the clinical integrity of the Tomotherapy machine. Method and Materials: This tool takes advantage of the output of the two distinct ion chamber systems on the Tomotherapy machine. One is the standard sealed ion chamber that resides in the head of a machine near the primary collimators and is used to calculate Monitor Units. The other is a set of pressurized Xenon detectors that are used for imaging. Both systems monitor ionizations independently and are rigidly attached so that their geometry is constant regardless of the orientation of the beam on the gantry which makes possible testing for both static and rotational modes. The collected data can be reviewed via a Web page and a downloadable Report in PDF format is available within seconds after collection of the data. Results: As an example, one performs a 200 second rotational delivery with the couch removed from the beam. The data are analyzed in both an integrated and pulse‐by pulse methodology to determine consistency between the two chamber systems, changes in output and changes in energy. The collected information is evaluated relative to a standard delivery created during machine commissioning. Comparison to standard ion chamber measurements in phantom under static conditions indicate that the analyses are consistent for calibration and more sensitive to energy changes than percentage depth dose measurements made in phantom. Additional information about the machine's performance is identified easily. Conclusion: New technology offers an opportunity to perform standard Quality Assurance tests in a new manner. The simple test described here is more sensitive and performed more quickly than traditional methodology. Other tests are possible. Conflict of Interest: Three authors are employees of Tomotherapy, Inc. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2561 / 2561
页数:1
相关论文
共 50 条
  • [31] Clinical implementation of Dosimetry Check™ for TomoTherapy® delivery quality assurance
    Chung, Eunah
    Kwon, Dongyeol
    Park, Taeyang
    Kang, Hyeri
    Chung, Yoonsun
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (06): : 193 - 199
  • [32] FILMLESS QUALITY ASSURANCE FOR HELICAL TOMOTHERAPY WITH A CYLINDRICAL STAIR-LIKE ALUMINIUM PHANTOM
    Althof, V.
    Kramer, D.
    Westendorp, R.
    van Haaren, P.
    Wispelweij, M.
    Minken, A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S92 - S93
  • [33] Clinical implementation of helical tomotherapy
    MacPherson, M.
    Gerig, L.
    Malone, S.
    MacRae, R.
    Fox, G.
    Carty, K.
    Montgomery, L.
    Clark, B.
    MEDICAL PHYSICS, 2006, 33 (07) : 2665 - 2665
  • [34] Tomotherapy daily quality assurance phantom
    Jaradat, H
    Paliwal, B
    Mehta, M
    MEDICAL PHYSICS, 2005, 32 (06) : 1989 - 1989
  • [35] Patient quality assurance analysis for tomotherapy
    Papanikolaou, N
    Shi, CY
    Yan, Y
    Weng, X
    MEDICAL PHYSICS, 2005, 32 (06) : 1986 - 1986
  • [36] Quality Assurance on Helical Tomotherapy Treatments with small target and high modulation factor using ArcCHECK
    Kong, C. W.
    Ho, Y. W.
    Geng, H.
    Lam, W. W.
    Chiu, T. L.
    Wong, W. K.
    Yu, S. K.
    Cheung, K. Y.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S759 - S759
  • [37] Quality assurance of an image guided intracranial stereotactic positioning system for radiosurgery treatment with helical tomotherapy
    Emilie T. Soisson
    Nick Hardcastle
    Wolfgang A. Tomé
    Journal of Neuro-Oncology, 2010, 98 : 277 - 285
  • [38] Quality assurance of an image guided intracranial stereotactic positioning system for radiosurgery treatment with helical tomotherapy
    Soisson, Emilie T.
    Hardcastle, Nick
    Tome, Wolfgang A.
    JOURNAL OF NEURO-ONCOLOGY, 2010, 98 (02) : 277 - 285
  • [39] Comparative Evaluation of Four Commercial Patient-Specific Quality Assurance Devices for Helical Tomotherapy
    Chang, K.
    Lee, J.
    Choi, J.
    Hong, C.
    Jung, D.
    Kim, J.
    Kim, J.
    Han, M.
    Lee, H.
    Kim, D.
    Kim, J.
    Park, K.
    Cho, J.
    Kim, Y.
    MEDICAL PHYSICS, 2019, 46 (06) : E611 - E611
  • [40] Statistical Analysis of Treatment Planning Parameters for Prediction of Delivery Quality Assurance Failure for Helical Tomotherapy
    Chang, Kyung Hwan
    Lee, Young Hyun
    Park, Byung Hun
    Han, Min Cheol
    Kim, Jihun
    Kim, Hojin
    Cho, Min-Seok
    Kang, Hyokyeong
    Lee, Ho
    Kim, Dong Wook
    Park, Kwangwoo
    Cho, Jaeho
    Kim, Yong Bae
    Kim, Jin Sung
    Hong, Chae-Seon
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2020, 19