Simplified clinical quality assurance for helical tomotherapy

被引:0
|
作者
Grant, W.
McGary, J.
Childress, N.
CravenS, R.
Krumbach, T.
Olivera, G.
机构
[1] Baylor Coll Med, Methodist Hosp, Houston, TX 77030 USA
[2] Tomotherapy Inc, Madison, WI USA
[3] Med Radiat Res Ctr, Madison, WI USA
关键词
D O I
10.1118/1.2761395
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate a Web‐based Quality Assurance tool for maintaining the clinical integrity of the Tomotherapy machine. Method and Materials: This tool takes advantage of the output of the two distinct ion chamber systems on the Tomotherapy machine. One is the standard sealed ion chamber that resides in the head of a machine near the primary collimators and is used to calculate Monitor Units. The other is a set of pressurized Xenon detectors that are used for imaging. Both systems monitor ionizations independently and are rigidly attached so that their geometry is constant regardless of the orientation of the beam on the gantry which makes possible testing for both static and rotational modes. The collected data can be reviewed via a Web page and a downloadable Report in PDF format is available within seconds after collection of the data. Results: As an example, one performs a 200 second rotational delivery with the couch removed from the beam. The data are analyzed in both an integrated and pulse‐by pulse methodology to determine consistency between the two chamber systems, changes in output and changes in energy. The collected information is evaluated relative to a standard delivery created during machine commissioning. Comparison to standard ion chamber measurements in phantom under static conditions indicate that the analyses are consistent for calibration and more sensitive to energy changes than percentage depth dose measurements made in phantom. Additional information about the machine's performance is identified easily. Conclusion: New technology offers an opportunity to perform standard Quality Assurance tests in a new manner. The simple test described here is more sensitive and performed more quickly than traditional methodology. Other tests are possible. Conflict of Interest: Three authors are employees of Tomotherapy, Inc. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2561 / 2561
页数:1
相关论文
共 50 条
  • [41] Dosimetric Comparison of Four Commercial Patient-Specific Quality Assurance Devices for Helical Tomotherapy
    Kyung Hwan Chang
    Dong Wook Kim
    Jung Hoan Choi
    Han-Back Shin
    Chae-Seon Hong
    Dong Min Jung
    Joo Ho Kim
    Jihun Kim
    Mincheol Han
    Ho Lee
    Kwangwoo Park
    Jin Sung Kim
    Jaeho Cho
    Yong Bae Kim
    Joo Ah Lee
    Journal of the Korean Physical Society, 2020, 76 : 257 - 263
  • [42] Dosimetric Comparison of Four Commercial Patient-Specific Quality Assurance Devices for Helical Tomotherapy
    Chang, Kyung Hwan
    Kim, Dong Wook
    Choi, Jung Hoan
    Shin, Han-Back
    Hong, Chae-Seon
    Jung, Dong Min
    Kim, Joo Ho
    Kim, Jihun
    Han, Mincheol
    Lee, Ho
    Park, Kwangwoo
    Kim, Jin Sung
    Cho, Jaeho
    Kim, Yong Bae
    Lee, Joo Ah
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 76 (03) : 257 - 263
  • [43] Rotational output and beam quality evaluations for helical tomotherapy with use of a third-party quality assurance tool
    Shimizu H.
    Sasaki K.
    Iwata M.
    Kawai M.
    Nakashima K.
    Kubota T.
    Osaki H.
    Nakayama M.
    Yoshimoto M.
    Kodaira T.
    Radiological Physics and Technology, 2016, 9 (1) : 53 - 59
  • [44] Clinical feasibility of TBI with helical tomotherapy
    Penagaricano, J. A.
    Chao, M.
    Van Rhee, F.
    Moros, E. G.
    Corry, P. M.
    Ratanatharathorn, V.
    BONE MARROW TRANSPLANTATION, 2011, 46 (07) : 929 - 935
  • [45] Clinical feasibility of TBI with helical tomotherapy
    J A Peñagarícano
    M Chao
    F Van Rhee
    E G Moros
    P M Corry
    V Ratanatharathorn
    Bone Marrow Transplantation, 2011, 46 : 929 - 935
  • [46] TomoEQA: Dose verification for patient-specific quality assurance in helical tomotherapy using an exit detector
    Han, Min Cheol
    Chang, Kyung Hwan
    Kim, Jihun
    Han, Su Chul
    Park, Kwangwoo
    Kim, Dong Wook
    Kim, Hojin
    Kim, Jin Sung
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 82 : 1 - 6
  • [47] Experience with Helical TomoTherapy Commissioning and Quality Assurance of Twin Peaks Linac vs. Earlier Models
    Movahed, A.
    Rabbani, B.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [48] Quality Assurance of Helical Tomotherapy Stereotactic Radiosurgery Treatment Using 4D Detector Array
    Lam, W.
    Geng, H.
    Kong, C.
    Cheung, K.
    Yu, S.
    Chiu, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S577 - S578
  • [49] Helical tomotherapy: description and clinical applications
    Dejean, C.
    Kantor, G.
    de Figueiredo, B. Henriques
    Lisbona, A.
    Mahe, M. -A.
    Mervoyer, A.
    Zefkili, S.
    Yassa, M.
    Giraud, P.
    BULLETIN DU CANCER, 2010, 97 (07) : 783 - 789
  • [50] Dosimetric and clinical review of helical tomotherapy
    Rong, Yi
    Welsh, James S.
    EXPERT REVIEW OF ANTICANCER THERAPY, 2011, 11 (02) : 309 - 320