Patient quality assurance analysis for tomotherapy

被引:0
|
作者
Papanikolaou, N [1 ]
Shi, CY [1 ]
Yan, Y [1 ]
Weng, X [1 ]
机构
[1] Univ Arkansas Med Sci, Little Rock, AR 72205 USA
关键词
D O I
10.1118/1.1997830
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: IMRT plans developed for conventional Linac equipped with dynamic MLC can be independently verified using a number of commercially available software packages. For the HiArt TomoTherapy unit however, the only dose verification mechanism is by measurement. The purpose of this investigation is to analyze the patient specific quality assurance results for the HiArt TomoTherapy intensity modulated radiotherapy treatment planning and delivery system in our clinic. Method and Materials: We have developed a systematic patient specific IMRT QA program that was implemented in April of 2004. Once a QA plan is calculated, the dose to a phantom is measured using ion chamber and film. The ion chamber is placed 5 mm below the film which in turn is placed in the equator of a cylindrical solid water phantom. After the plan is delivered to the phantom, the point dose is recorded and the film is processed. Film calibration is performed daily using an in‐house developed protocol and software tool. Dosimetric analysis is performed after the film and planar dose are co‐registered in the TomoTherapy planning station. In total, 63 patients were analyzed. Results: Dosimetric analysis was performed based on both film and ion chamber measurements. The median and mode discrepancy is below 2% for the point measurements. Similar results are found for the film analysis which provides not only absolute dosimetry but also isodose distribution and profile comparison between measured and calculated planar dose distributions. The plane and points of calculation can introduce small errors in the analysis. Conclusion: A comprehensive patient QA program has been developed and the results of 63 patients are analyzed in this paper. Given the novel approach of TomoTherapy towards IMRT, it is important to see that for the majority of the patients the deviation between planned and delivered doses is less than 2%. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1986 / 1986
页数:1
相关论文
共 50 条
  • [1] Patient specific quality assurance for helical tomotherapy
    Thomas, S
    MacKenzie, M
    Field, G
    Syme, A
    Fallone, B
    MEDICAL PHYSICS, 2005, 32 (07) : 2414 - 2414
  • [2] Inter-institution comparison of patient quality assurance analysis for tomotherapy
    Shi, C.
    Yan, Y.
    Wu, C.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2006, 33 (06) : 2113 - 2114
  • [3] Evaluation of the "Delivery Analysis™" software for patient's specific quality assurance on tomotherapy
    Vallet, V.
    Schopfer, M.
    Moeckli, R.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 867 - 867
  • [4] Helical Tomotherapy Patient Specific Quality Assurance in An Anthropomorphic Phantom
    Neeley, M.
    Harris, C.
    Charara, Y.
    Ramsey, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [5] Quality assurance of serial tomotherapy for head and neck patient treatments
    Low, DA
    Chao, KSC
    Mutic, S
    Gerber, RL
    Perez, CA
    Purdy, JA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (03): : 681 - 692
  • [6] Helical tomotherapy quality assurance using sinogram analysis
    Mahan, S
    Ramsey, C
    Chase, D
    MEDICAL PHYSICS, 2004, 31 (06) : 1832 - 1832
  • [7] Helical tomotherapy quality assurance
    Balog, John
    Soisson, Emilie
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : S113 - S117
  • [8] Analysis of the Effect of Tomotherapy Plan Parameters on Patient-Specific Delivery Quality Assurance (DQA)
    Kim, Jina
    Kay, Chul-Seung
    Jang, Hong-Seok
    Kang, Young-nam
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2019, 75 (12) : 1043 - 1047
  • [9] Analysis of the Effect of Tomotherapy Plan Parameters on Patient-Specific Delivery Quality Assurance (DQA)
    Jina Kim
    Chul-Seung Kay
    Hong-Seok Jang
    Young-nam Kang
    Journal of the Korean Physical Society, 2019, 75 : 1043 - 1047
  • [10] Tomotherapy daily quality assurance phantom
    Jaradat, H
    Paliwal, B
    Mehta, M
    MEDICAL PHYSICS, 2005, 32 (06) : 1989 - 1989