Patient quality assurance analysis for tomotherapy

被引:0
|
作者
Papanikolaou, N [1 ]
Shi, CY [1 ]
Yan, Y [1 ]
Weng, X [1 ]
机构
[1] Univ Arkansas Med Sci, Little Rock, AR 72205 USA
关键词
D O I
10.1118/1.1997830
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: IMRT plans developed for conventional Linac equipped with dynamic MLC can be independently verified using a number of commercially available software packages. For the HiArt TomoTherapy unit however, the only dose verification mechanism is by measurement. The purpose of this investigation is to analyze the patient specific quality assurance results for the HiArt TomoTherapy intensity modulated radiotherapy treatment planning and delivery system in our clinic. Method and Materials: We have developed a systematic patient specific IMRT QA program that was implemented in April of 2004. Once a QA plan is calculated, the dose to a phantom is measured using ion chamber and film. The ion chamber is placed 5 mm below the film which in turn is placed in the equator of a cylindrical solid water phantom. After the plan is delivered to the phantom, the point dose is recorded and the film is processed. Film calibration is performed daily using an in‐house developed protocol and software tool. Dosimetric analysis is performed after the film and planar dose are co‐registered in the TomoTherapy planning station. In total, 63 patients were analyzed. Results: Dosimetric analysis was performed based on both film and ion chamber measurements. The median and mode discrepancy is below 2% for the point measurements. Similar results are found for the film analysis which provides not only absolute dosimetry but also isodose distribution and profile comparison between measured and calculated planar dose distributions. The plane and points of calculation can introduce small errors in the analysis. Conclusion: A comprehensive patient QA program has been developed and the results of 63 patients are analyzed in this paper. Given the novel approach of TomoTherapy towards IMRT, it is important to see that for the majority of the patients the deviation between planned and delivered doses is less than 2%. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1986 / 1986
页数:1
相关论文
共 50 条
  • [31] Clinical Implementation of the New Dosimetry System for TomoTherapy Patient Delivery Quality Assurance (DQA)
    Chung, E.
    Kwon, D.
    Park, T.
    Kang, H.
    Chung, Y.
    MEDICAL PHYSICS, 2017, 44 (06) : 2894 - 2894
  • [32] Evaluation and Validation of IBA I'MatriXX Array for Patient-Specific Quality Assurance of TomoTherapy®
    Sresty, N. V. N. Madhusudhana
    Raju, A. Krishnam
    Reddy, B. Nagarjuna
    Sahithya, V. C.
    Mohmd, Yakub
    Kumar, G. Deleep
    Kumar, T. Anil
    Rushdi, Tasneem
    Aparna, S.
    Prasad, G. Durga
    Bajwa, Harjot Kaur
    JOURNAL OF MEDICAL PHYSICS, 2019, 44 (03) : 222 - 227
  • [33] Comparative Evaluation of Four Commercial Patient-Specific Quality Assurance Devices for Helical Tomotherapy
    Chang, K.
    Lee, J.
    Choi, J.
    Hong, C.
    Jung, D.
    Kim, J.
    Kim, J.
    Han, M.
    Lee, H.
    Kim, D.
    Kim, J.
    Park, K.
    Cho, J.
    Kim, Y.
    MEDICAL PHYSICS, 2019, 46 (06) : E611 - E611
  • [34] Filmless methods for quality assurance of Tomotherapy using ArcCHECK
    Yang, B.
    Wong, W. K. R.
    Geng, H.
    Lam, W. W.
    Ho, Y. W.
    Kwok, W. M.
    Cheung, K. Y.
    Yu, S. K.
    MEDICAL PHYSICS, 2017, 44 (01) : 7 - 16
  • [35] Development of a supplemental quality assurance program for a tomotherapy unit
    Caprile, P.
    Hartmann, G.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S82 - S83
  • [36] Dosimetric Comparison of Four Commercial Patient-Specific Quality Assurance Devices for Helical Tomotherapy
    Kyung Hwan Chang
    Dong Wook Kim
    Jung Hoan Choi
    Han-Back Shin
    Chae-Seon Hong
    Dong Min Jung
    Joo Ho Kim
    Jihun Kim
    Mincheol Han
    Ho Lee
    Kwangwoo Park
    Jin Sung Kim
    Jaeho Cho
    Yong Bae Kim
    Joo Ah Lee
    Journal of the Korean Physical Society, 2020, 76 : 257 - 263
  • [37] Dosimetric Comparison of Four Commercial Patient-Specific Quality Assurance Devices for Helical Tomotherapy
    Chang, Kyung Hwan
    Kim, Dong Wook
    Choi, Jung Hoan
    Shin, Han-Back
    Hong, Chae-Seon
    Jung, Dong Min
    Kim, Joo Ho
    Kim, Jihun
    Han, Mincheol
    Lee, Ho
    Park, Kwangwoo
    Kim, Jin Sung
    Cho, Jaeho
    Kim, Yong Bae
    Lee, Joo Ah
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 76 (03) : 257 - 263
  • [38] Quality assurance for helical tomotherapy system and the mechanical stability
    Takahashi, Y.
    Sumida, I.
    Yamamoto, N.
    Asano, H.
    Furukawa, S.
    Uchiyama, Y.
    Yamashita, T.
    Matsuo, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2485 - 2486
  • [39] An independent delivery quality assurance calculation for the tomotherapy linac
    Woo, M.
    Ramsey, C.
    Seibert, R.
    MEDICAL PHYSICS, 2007, 34 (06) : 2416 - 2416
  • [40] A new multipurpose quality assurance phantom for clinical tomotherapy
    Smilowitz, J
    Balog, J
    Keller, H
    Olivera, G
    DeWerd, LA
    Mackie, TR
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1191 - 1194