Motion correction and volumetric reconstruction for fetal functional magnetic resonance imaging data

被引:12
|
作者
Sobotka, Daniel [1 ]
Ebner, Michael [3 ]
Schwartz, Ernst [1 ]
Nenning, Karl-Heinz [1 ,4 ]
Taymourtash, Athena [1 ]
Vercauteren, Tom [3 ]
Ourselin, Sebastien [3 ]
Kasprian, Gregor [2 ]
Prayer, Daniela [2 ]
Langs, Georg [1 ]
Licandro, Roxane [1 ,5 ,6 ]
机构
[1] Med Univ Vienna, Dept Biomed Imaging & Image guided Therapy, Computat Imaging Res Lab, Vienna, Austria
[2] Med Univ Vienna, Dept Biomed Imaging & Image guided Therapy, Div Neuroradiol & Musculoskeletal Radiol, Vienna, Austria
[3] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
[4] Nathan S Kline Inst Psychiat Res, Ctr Biomed Imaging & Neuromodulat, Orangeburg, NY USA
[5] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Lab Computat Neuroimaging, Charlestown, MA USA
[6] Harvard Med Sch, Charlestown, MA USA
基金
奥地利科学基金会; 英国惠康基金; 英国工程与自然科学研究理事会; 欧盟地平线“2020”;
关键词
Fetal fMRI; Motion correction; Regularization; Functional connectivity; IN-UTERO; BRAIN; CONNECTIVITY; FMRI; ROBUST; MRI; CORTEX; REGISTRATION; ARTIFACTS; FRAMEWORK;
D O I
10.1016/j.neuroimage.2022.119213
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Motion correction is an essential preprocessing step in functional Magnetic Resonance Imaging (fMRI) of the fetal brain with the aim to remove artifacts caused by fetal movement and maternal breathing and consequently to suppress erroneous signal correlations. Current motion correction approaches for fetal fMRI choose a single 3D volume from a specific acquisition timepoint with least motion artefacts as reference volume, and perform interpolation for the reconstruction of the motion corrected time series. The results can suffer, if no low-motion frame is available, and if reconstruction does not exploit any assumptions about the continuity of the fMRI signal. Here, we propose a novel framework, which estimates a high-resolution reference volume by using outlier robust motion correction, and by utilizing Huber L2 regularization for intra-stack volumetric reconstruction of the motion-corrected fetal brain fMRI. We performed an extensive parameter study to investigate the effectiveness of motion estimation and present in this work benchmark metrics to quantify the effect of motion correction and regularised volumetric reconstruction approaches on functional connectivity computations. We demonstrate the proposed framework's ability to improve functional connectivity estimates, reproducibility and signal interpretability, which is clinically highly desirable for the establishment of prognostic noninvasive imaging biomarkers. The motion correction and volumetric reconstruction framework is made available as an open-source package of NiftyMIC.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation
    Goolaub, Datta Singh
    Marini, Davide
    Seed, Mike
    Macgowan, Christopher K.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2021, (167): : 1 - 13
  • [32] Normative volumetric data of the developing hippocampus in children based on magnetic resonance imaging
    Pfluger, T
    Weil, S
    Weis, S
    Vollmar, C
    Heiss, D
    Egger, J
    Scheck, R
    Hahn, K
    EPILEPSIA, 1999, 40 (04) : 414 - 423
  • [33] Motion correction in magnetic resonance spectroscopy
    Saleh, Muhammad G.
    Edden, Richard A. E.
    Chang, Linda
    Ernst, Thomas
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) : 2312 - 2326
  • [34] Evaluation of motion and realignment for functional magnetic resonance imaging in real time
    Mathiak, K
    Posse, S
    MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (01) : 167 - 171
  • [35] Volumetric Magnetic Resonance Imaging of the Musculoskeletal System
    Rosas, Humberto
    Kijowski, Richard
    SEMINARS IN ROENTGENOLOGY, 2013, 48 (02) : 140 - 147
  • [36] Ganglionic eminence: volumetric assessment of transient brain structure utilizing fetal magnetic resonance imaging
    Stuempflen, M.
    Taymourtash, A.
    Kienast, P.
    Schmidbauer, V. U.
    Schwartz, E.
    Mitter, C.
    Binder, J.
    Prayer, D.
    Kasprian, G.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2023, 62 (03) : 405 - 413
  • [37] A volumetric magnetic resonance imaging study in migraine
    Laila Elmously Naguib
    Ghada Saed Abdel Azim
    Mohammed Abdelrazek Abdellatif
    The Egyptian Journal of Neurology, Psychiatry and Neurosurgery, 57
  • [38] A volumetric magnetic resonance imaging study in migraine
    Naguib, Laila Elmously
    Azim, Ghada Saed Abdel
    Abdellatif, Mohammed Abdelrazek
    EGYPTIAN JOURNAL OF NEUROLOGY PSYCHIATRY AND NEUROSURGERY, 2021, 57 (01):
  • [39] Reconstruction of the articular facets of the subtalar and talonavicular joints from volumetric magnetic resonance data
    Ward, KA
    Willott, J
    Paxton, S
    Soames, RW
    CLINICAL ANATOMY, 2001, 14 (04) : 272 - 277
  • [40] Cerebral biometry in fetal magnetic resonance imaging: new reference data
    Tilea, B.
    Alberti, C.
    Adamsbaum, C.
    Armoogum, P.
    Oury, J. F.
    Cabrol, D.
    Sebag, G.
    Kalifa, G.
    Garel, C.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2009, 33 (02) : 173 - 180