Motion correction and volumetric reconstruction for fetal functional magnetic resonance imaging data

被引:12
|
作者
Sobotka, Daniel [1 ]
Ebner, Michael [3 ]
Schwartz, Ernst [1 ]
Nenning, Karl-Heinz [1 ,4 ]
Taymourtash, Athena [1 ]
Vercauteren, Tom [3 ]
Ourselin, Sebastien [3 ]
Kasprian, Gregor [2 ]
Prayer, Daniela [2 ]
Langs, Georg [1 ]
Licandro, Roxane [1 ,5 ,6 ]
机构
[1] Med Univ Vienna, Dept Biomed Imaging & Image guided Therapy, Computat Imaging Res Lab, Vienna, Austria
[2] Med Univ Vienna, Dept Biomed Imaging & Image guided Therapy, Div Neuroradiol & Musculoskeletal Radiol, Vienna, Austria
[3] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
[4] Nathan S Kline Inst Psychiat Res, Ctr Biomed Imaging & Neuromodulat, Orangeburg, NY USA
[5] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Lab Computat Neuroimaging, Charlestown, MA USA
[6] Harvard Med Sch, Charlestown, MA USA
基金
奥地利科学基金会; 英国惠康基金; 英国工程与自然科学研究理事会; 欧盟地平线“2020”;
关键词
Fetal fMRI; Motion correction; Regularization; Functional connectivity; IN-UTERO; BRAIN; CONNECTIVITY; FMRI; ROBUST; MRI; CORTEX; REGISTRATION; ARTIFACTS; FRAMEWORK;
D O I
10.1016/j.neuroimage.2022.119213
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Motion correction is an essential preprocessing step in functional Magnetic Resonance Imaging (fMRI) of the fetal brain with the aim to remove artifacts caused by fetal movement and maternal breathing and consequently to suppress erroneous signal correlations. Current motion correction approaches for fetal fMRI choose a single 3D volume from a specific acquisition timepoint with least motion artefacts as reference volume, and perform interpolation for the reconstruction of the motion corrected time series. The results can suffer, if no low-motion frame is available, and if reconstruction does not exploit any assumptions about the continuity of the fMRI signal. Here, we propose a novel framework, which estimates a high-resolution reference volume by using outlier robust motion correction, and by utilizing Huber L2 regularization for intra-stack volumetric reconstruction of the motion-corrected fetal brain fMRI. We performed an extensive parameter study to investigate the effectiveness of motion estimation and present in this work benchmark metrics to quantify the effect of motion correction and regularised volumetric reconstruction approaches on functional connectivity computations. We demonstrate the proposed framework's ability to improve functional connectivity estimates, reproducibility and signal interpretability, which is clinically highly desirable for the establishment of prognostic noninvasive imaging biomarkers. The motion correction and volumetric reconstruction framework is made available as an open-source package of NiftyMIC.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Fetal magnetic resonance imaging
    Nagae, Lidia Mayumi
    Baroni, Ronaldo Hueb
    de Gusmao Funari, Marcelo Buarque
    EINSTEIN-SAO PAULO, 2009, 7 (03): : 390 - 391
  • [22] Normative linear and volumetric biometric measurements of fetal brain development in magnetic resonance imaging
    Cai, Shulei
    Zhang, Guofu
    Zhang, He
    Wang, Jing
    CHILDS NERVOUS SYSTEM, 2020, 36 (12) : 2997 - 3005
  • [23] Normative linear and volumetric biometric measurements of fetal brain development in magnetic resonance imaging
    Shulei Cai
    Guofu Zhang
    He Zhang
    Jing Wang
    Child's Nervous System, 2020, 36 : 2997 - 3005
  • [24] A survey on Motion Artifact Correction in Magnetic Resonance Imaging for Improved Diagnostics
    Tripathi V.R.
    Tibdewal M.N.
    Mishra R.
    SN Computer Science, 5 (3)
  • [25] Regularized motion correction algorithm for diffusion weighted magnetic resonance imaging
    Fang, Sheng
    Zhao, Li
    Ying, Kui
    Cheng, Jianping
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2010, 50 (08): : 1154 - 1157
  • [26] Field inhomogeneity correction based on gridding reconstruction for magnetic resonance imaging
    Eggers, Holger
    Knopp, Tobias
    Potts, Daniel
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (03) : 374 - 384
  • [27] Spatially filtering functional magnetic resonance imaging data
    Lowe, MJ
    Sorenson, JA
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (05) : 723 - 729
  • [28] Functional magnetic resonance imaging based on large data
    Zeng, Weiyi
    Zou, Sanyong
    Zuo, Hao
    Lecture Notes in Electrical Engineering, 2015, 334 : 987 - 994
  • [29] Probabilistic analysis of functional magnetic resonance imaging data
    Frank, LR
    Buxton, RB
    Wong, EC
    MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (01) : 132 - 148
  • [30] Physiological noise reduction using volumetric functional magnetic resonance inverse imaging
    Lin, Fa-Hsuan
    Nummenmaa, Aapo
    Witzel, Thomas
    Polimeni, Jonathan R.
    Zeffiro, Thomas A.
    Wang, Fu-Nien
    Belliveau, John W.