Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner

被引:129
|
作者
Kamel, EM [1 ]
Burger, C [1 ]
Buck, A [1 ]
von Schulthess, GK [1 ]
Goerres, GW [1 ]
机构
[1] Univ Zurich Hosp, Div Nucl Med, CH-8091 Zurich, Switzerland
关键词
PET; CT; attenuation correction; artifacts;
D O I
10.1007/s00330-002-1564-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our objective was to study the effect of metal-induced artifacts on the accuracy of the CT-based anatomic map as a prerequisite for attenuation correction of the positron emission tomography (PET) emission data. Twenty-seven oncology patients with dental metalwork were enrolled in the present study. Data acquisition was performed on a PET/CT in-line system (Discovery LS, GE Medical Systems, Milwaukee, Wis.). Attenuation correction of emission data was done twice, using an 80-mA CT scan (PETCT80) and a Ge-68 transmission scan (PET68Ge)Average count in kBq/cc was measured in regions with and without artifacts and compared for PETCT80 and PET68Ge. Data analysis of region of interests (ROIs) revealed that the ratio (ROIs PETCT80/ROIs PET68Ge) and the difference (ROIs PETCT80 minus ROIs PET68Ge) had a higher mean of values in regions with artifacts than in regions without artifacts (1.2 +/- 0.17 vs 1.06 +/- 0.06 and 0.68 +/- 0.67 vs 0.15 +/- 0.17 kBq/cc, respectively). For most of the studied artifactual ROIs, the PETCT80 values were higher than those of the PET68Ge. Attenuation correction of PET emission data using an artifactual CT map yields false values in regions nearby artifacts caused by dental metalwork. This may falsely estimate PET quantitative studies and may disturb the visual interpretation of PET scan.
引用
收藏
页码:724 / 728
页数:5
相关论文
共 50 条
  • [41] Effect of oral contrast agents on CT-based PET attenuation correction in dual-modality PET/CT tomography
    Antoch, G
    Jentzen, W
    Stattaus, J
    Mueller, SP
    Bockisch, A
    Debatin, JF
    RADIOLOGY, 2002, 225 : 423 - 424
  • [42] Dual-modality PET/CT imaging: CT-based attenuation correction in the presence of CT contrast agents.
    Beyer, T
    Townsend, DW
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 56P - 56P
  • [43] Impact of Ge-68/Ga-68-based versus CT-based attenuation correction on PET
    van Dalen, Jorn A.
    Visser, Eric P.
    Vogel, Wouter V.
    Corstens, Frans H. M.
    Oyen, Wim J. G.
    MEDICAL PHYSICS, 2007, 34 (03) : 889 - 897
  • [44] CT Attenuation correction for myocardial perfusion quantification using a PET/CT hybrid scanner
    Koepfli, P
    Hany, TF
    Wyss, CA
    Namdar, M
    Burger, C
    Konstantinidis, AV
    Berthold, T
    von Schulthess, GK
    Kaufmann, PA
    JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (04) : 537 - 542
  • [45] Effect of smart mA CT attenuation correction on PET/CT scanner spatial resolution
    Belakhlef, Sam
    Church, Clifford
    Fortenbery, Edwin
    Lakhanpal, Suresh
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [46] Effects of CT-based attenuation correction on quantitative SPECT/CT of jawbone
    Tsuchitani, Tatsuya
    Kitajima, Kazuhiro
    Takahashi, Yoshiyuki
    Yoshida, Rika
    Kiada, Hayato
    Tsurusaki, Masakatsu
    Minami, Tetsuya
    Kotura, Noriko
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2023, 26 (02) : 108 - 113
  • [47] A Curve Fitting Approach Using ANN for Converting CT Number to Linear Attenuation Coefficient for CT-based PET Attenuation Correction
    Lai, Chia-Lin
    Lee, Jhih-Shian
    Chen, Jyh-Cheng
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (01) : 164 - 170
  • [48] Comparative Assessment of Energy-Mapping Approaches in CT-Based Attenuation Correction for PET
    Ay, Mohammad R.
    Shirmohammad, Maryam
    Sarkar, Saeed
    Rahmim, Arman
    Zaidi, Habib
    MOLECULAR IMAGING AND BIOLOGY, 2011, 13 (01) : 187 - 198
  • [49] CT based attenuation correction using a combined PET/CT scanner: Influence of the respiration level on measured FDG concentration in normal tissues.
    Goerres, G
    Buehler, TC
    Burger, C
    Steinert, HC
    von Schulthess, GK
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 216P - 217P
  • [50] Comparison of different CT-based attenuation correction schemes for PET with respiratory motion.
    Qi, J
    Huesman, RH
    Reutter, BW
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 38P - 38P