Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner

被引:129
|
作者
Kamel, EM [1 ]
Burger, C [1 ]
Buck, A [1 ]
von Schulthess, GK [1 ]
Goerres, GW [1 ]
机构
[1] Univ Zurich Hosp, Div Nucl Med, CH-8091 Zurich, Switzerland
关键词
PET; CT; attenuation correction; artifacts;
D O I
10.1007/s00330-002-1564-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our objective was to study the effect of metal-induced artifacts on the accuracy of the CT-based anatomic map as a prerequisite for attenuation correction of the positron emission tomography (PET) emission data. Twenty-seven oncology patients with dental metalwork were enrolled in the present study. Data acquisition was performed on a PET/CT in-line system (Discovery LS, GE Medical Systems, Milwaukee, Wis.). Attenuation correction of emission data was done twice, using an 80-mA CT scan (PETCT80) and a Ge-68 transmission scan (PET68Ge)Average count in kBq/cc was measured in regions with and without artifacts and compared for PETCT80 and PET68Ge. Data analysis of region of interests (ROIs) revealed that the ratio (ROIs PETCT80/ROIs PET68Ge) and the difference (ROIs PETCT80 minus ROIs PET68Ge) had a higher mean of values in regions with artifacts than in regions without artifacts (1.2 +/- 0.17 vs 1.06 +/- 0.06 and 0.68 +/- 0.67 vs 0.15 +/- 0.17 kBq/cc, respectively). For most of the studied artifactual ROIs, the PETCT80 values were higher than those of the PET68Ge. Attenuation correction of PET emission data using an artifactual CT map yields false values in regions nearby artifacts caused by dental metalwork. This may falsely estimate PET quantitative studies and may disturb the visual interpretation of PET scan.
引用
收藏
页码:724 / 728
页数:5
相关论文
共 50 条
  • [31] Contrast artifact correction in CT-based attenuation correction
    Chen, T.
    Lin, H. H.
    Chuang, K. S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S285 - S285
  • [32] Reduction of dental filling metallic artifacts in CT-based attenuation correction of PET data using weighted virtual sinograms optimized by a genetic algorithm
    Abdoli, Mehrsima
    Ay, Mohammad Reza
    Ahmadian, Alireza
    Dierckx, Rudi A. J. O.
    Zaidi, Habib
    MEDICAL PHYSICS, 2010, 37 (12) : 6166 - 6177
  • [33] A Comparison of CT-based Attenuation Correction Strategies for PET Data of Moving Structures
    Richter, Christian
    Hoinkis, Cordelia
    Just, Uwe
    Poenisch, Falk
    Woithe, Julia
    Enghardt, Wolfgang
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3919 - 3922
  • [34] Dosimetry and adequacy of CT-based attenuation correction for pediatric PET: Phantom study
    Fahey, Frederic H.
    Palmer, Matthew R.
    Strauss, Keith J.
    Zimmerman, Robert E.
    Badawi, Ramsey D.
    Treves, S. Ted
    RADIOLOGY, 2007, 243 (01) : 96 - 104
  • [35] Bias in PET Images of Solid Phantoms Due to CT-Based Attenuation Correction
    Byrd, Darrin W.
    Sunderland, John J.
    Lee, Tzu-Cheng
    Kinahan, Paul E.
    TOMOGRAPHY, 2019, 5 (01) : 154 - 160
  • [36] Method for discrimination of contrast media in CT-based PET attenuation correction.
    Laymon, CM
    Carney, J
    Townsend, D
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 273P - 274P
  • [37] Impact of CT-based Attenuation Correction on the Registration Between Dual-gated Cardiac PET and High-Resolution CT
    Turco, A.
    Gheysens, O.
    Nuyts, J.
    Duchenne, J.
    Voigt, J. U.
    Claus, P.
    Vunckx, K.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (01) : 180 - 192
  • [38] Impact of X-ray tube settings and metallic leads on neurological PET imaging when using CT-based attenuation correction
    Ay, Mohammad Reza
    Zaidi, Habib
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 411 - 414
  • [39] Impact of CT-based attenuation and scatter correction on myocardial SPECT images
    van Dalen, J. A.
    Sellis, M.
    de Bruin, W. I.
    Wyndaele, D. N. J.
    Slump, C. H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S286 - S286
  • [40] A Novel Dual Energy CT-Based Attenuation Correction Method in PET/CT Systems: A Phantom Study
    Teimourian, Behnoosh
    Ay, Mohammad Reza
    Zafarghandi, Mojtaba Shamsaei
    Ghadiri, Hossein
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2009, 17 (02): : 42 - 49