Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner

被引:129
|
作者
Kamel, EM [1 ]
Burger, C [1 ]
Buck, A [1 ]
von Schulthess, GK [1 ]
Goerres, GW [1 ]
机构
[1] Univ Zurich Hosp, Div Nucl Med, CH-8091 Zurich, Switzerland
关键词
PET; CT; attenuation correction; artifacts;
D O I
10.1007/s00330-002-1564-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our objective was to study the effect of metal-induced artifacts on the accuracy of the CT-based anatomic map as a prerequisite for attenuation correction of the positron emission tomography (PET) emission data. Twenty-seven oncology patients with dental metalwork were enrolled in the present study. Data acquisition was performed on a PET/CT in-line system (Discovery LS, GE Medical Systems, Milwaukee, Wis.). Attenuation correction of emission data was done twice, using an 80-mA CT scan (PETCT80) and a Ge-68 transmission scan (PET68Ge)Average count in kBq/cc was measured in regions with and without artifacts and compared for PETCT80 and PET68Ge. Data analysis of region of interests (ROIs) revealed that the ratio (ROIs PETCT80/ROIs PET68Ge) and the difference (ROIs PETCT80 minus ROIs PET68Ge) had a higher mean of values in regions with artifacts than in regions without artifacts (1.2 +/- 0.17 vs 1.06 +/- 0.06 and 0.68 +/- 0.67 vs 0.15 +/- 0.17 kBq/cc, respectively). For most of the studied artifactual ROIs, the PETCT80 values were higher than those of the PET68Ge. Attenuation correction of PET emission data using an artifactual CT map yields false values in regions nearby artifacts caused by dental metalwork. This may falsely estimate PET quantitative studies and may disturb the visual interpretation of PET scan.
引用
收藏
页码:724 / 728
页数:5
相关论文
共 50 条
  • [21] Impact of Ge-68-based versus CT-based attenuation correction on PET imaging
    van Dalen, J. A.
    Visser, E. P.
    Vogel, W. V.
    Corstens, F. H. M.
    Oyen, W. J. G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S314 - S315
  • [22] Simulation-based Assessment of the Impact of Contrast Medium on CT-based Attenuation Correction in PET
    Ay, Mohamad Reza
    Zaidi, Habib
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2731 - 2735
  • [23] Effect of chemoembolizing agents on the CT-based PET attenuation correction in dual-modality PET/CT
    Antoch, G
    Fronz, U
    Veit, P
    Freudenberg, LS
    Jentzen, W
    Brandau, W
    Bockisch, A
    Verhagen, R
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S331 - S331
  • [24] Low-dose CT scans for CT-based attenuation correction in PET/CT imaging.
    Bai, C
    Shao, L
    Da Silva, AJ
    Zhao, Z
    Hines, H
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 104P - 105P
  • [25] A method for calibrating the CT-based attenuation correction of PET in human tissue
    Watson, CC
    Rappoport, V
    Faul, D
    Townsend, DW
    Carney, JP
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 102 - 107
  • [26] CT-based attenuation correction in PET image reconstruction for the Gemini system
    Bai, CY
    Tung, CH
    Kolthammer, J
    Shao, L
    Brown, KM
    Zhao, Z
    Da Silva, AJ
    Ye, JH
    Gagnon, D
    Parma, M
    Walsh, E
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3082 - 3086
  • [27] A novel energy mapping approach for CT-based attenuation correction in PET
    Teimourian, B.
    Ay, M. R.
    Zafarghandi, M. Shamsaie
    Ghafarian, P.
    Ghadiri, H.
    Zaidi, H.
    MEDICAL PHYSICS, 2012, 39 (04) : 2078 - 2089
  • [28] A method for calibrating the CT-based attenuation correction of PET in human tissue
    Watson, CC
    Rappoport, V
    Faul, D
    Townsend, DW
    Carney, JP
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3487 - 3491
  • [29] A simple and reliable procedure to evaluate and optimize CT-based Attenuation Correction (CTAC) for PET/CT
    Caselles, O.
    Nalis, J.
    Brillouet, S.
    Serre, D.
    Marre, D.
    Girault, S.
    Zerdoud, S.
    Courbon, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S96 - S96
  • [30] Reduction of artifacts arising from metal hip implants during CT-based attenuation correction in oncological PET-CT studies
    Abdoli, Mehrsima
    Ay, Mohammad
    de Jong, Johan
    Pruim, Jan
    Dierckx, Rudi
    Zaidi, Habib
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52