Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner

被引:129
|
作者
Kamel, EM [1 ]
Burger, C [1 ]
Buck, A [1 ]
von Schulthess, GK [1 ]
Goerres, GW [1 ]
机构
[1] Univ Zurich Hosp, Div Nucl Med, CH-8091 Zurich, Switzerland
关键词
PET; CT; attenuation correction; artifacts;
D O I
10.1007/s00330-002-1564-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our objective was to study the effect of metal-induced artifacts on the accuracy of the CT-based anatomic map as a prerequisite for attenuation correction of the positron emission tomography (PET) emission data. Twenty-seven oncology patients with dental metalwork were enrolled in the present study. Data acquisition was performed on a PET/CT in-line system (Discovery LS, GE Medical Systems, Milwaukee, Wis.). Attenuation correction of emission data was done twice, using an 80-mA CT scan (PETCT80) and a Ge-68 transmission scan (PET68Ge)Average count in kBq/cc was measured in regions with and without artifacts and compared for PETCT80 and PET68Ge. Data analysis of region of interests (ROIs) revealed that the ratio (ROIs PETCT80/ROIs PET68Ge) and the difference (ROIs PETCT80 minus ROIs PET68Ge) had a higher mean of values in regions with artifacts than in regions without artifacts (1.2 +/- 0.17 vs 1.06 +/- 0.06 and 0.68 +/- 0.67 vs 0.15 +/- 0.17 kBq/cc, respectively). For most of the studied artifactual ROIs, the PETCT80 values were higher than those of the PET68Ge. Attenuation correction of PET emission data using an artifactual CT map yields false values in regions nearby artifacts caused by dental metalwork. This may falsely estimate PET quantitative studies and may disturb the visual interpretation of PET scan.
引用
收藏
页码:724 / 728
页数:5
相关论文
共 50 条
  • [1] Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner
    Ehab M. Kamel
    Cyrill Burger
    Alfred Buck
    Gustav K. von Schulthess
    Gerhard W. Goerres
    European Radiology, 2003, 13 : 724 - 728
  • [2] CT-Based Attenuation Correction on the FLEX Triumph Preclinical PET/CT Scanner
    Prasad, Rameshwar
    Ay, Mohammad R.
    Ratib, Osman
    Zaidi, Habib
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (01) : 66 - 75
  • [3] CT-based attenuation correction on the FLEX Triumph™ preclinical PET/CT scanner
    Prasad, Rameshwar
    Ay, Mohammad R.
    Ratib, Osman
    Zaidi, Habib
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3357 - +
  • [4] CT-based vs Ge-68 rotating source attenuation correction in a combined PET-CT scanner
    Kamel, EM
    Hany, TF
    Burger, CN
    Tokman, A
    Altman, H
    Von Schulthess, GK
    RADIOLOGY, 2001, 221 : 564 - 565
  • [5] Impact of transient oral contrast agent on CT-based attenuation correction in combined PET/CT studies
    Burger, CN
    Dizendorf, EV
    Hany, TF
    Buck, A
    Von Schulthess, GK
    RADIOLOGY, 2002, 225 : 409 - 409
  • [6] Does a Metallic Implant influence the CT-based attenuation correction factors in CT-PET?
    De Marco, M.
    Tesei, L.
    Bernardini, S. R.
    Maggi, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S194 - S194
  • [7] Development of attenuation correction for a combined PET/SPECT/CT scanner
    Matsumoto, K.
    Magata, Y.
    Wada, Y.
    Yamaguchi, H.
    Murase, K.
    Mukai, T.
    Watanabe, Y.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S490 - S490
  • [8] Automated CT-based Attenuation Correction for Preclinical Multimodality PET/CT
    Chen, Mu
    Osborne, Dustin
    Gleason, Shaun
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4043 - +
  • [9] Accuracy of CT-based attenuation correction in PET/CT bone imaging
    Abella, Monica
    Alessio, Adam M.
    Mankoff, David A.
    MacDonald, Lawrence R.
    Jose Vaquero, Juan
    Desco, Manuel
    Kinahan, Paul E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (09):
  • [10] Accuracy of CT-Based attenuation correction in bone Imaging with PET/CT
    Abella, M.
    Mankof, D.
    Vaquero, J. J.
    Desco, M.
    Kinahan, P. E.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4485 - +