Electrochemical sensor based on phospholipid modified glassy carbon electrode - determination of paraquat

被引:28
|
作者
Tomkova, H. [1 ]
Sokolova, R. [2 ]
Opletal, T. [1 ]
Kucerova, P. [1 ]
Kucera, L. [1 ]
Souckova, J. [1 ]
Skopalova, J. [1 ]
Bartak, P. [1 ]
机构
[1] Palacky Univ, Reg Ctr Adv Technol & Mat, Dept Analyt Chem, Fac Sci, 17 Listopadu 12, Olomouc 77146, Czech Republic
[2] Czech Acad Sci, J Heyrovsky Inst Phys Chem, Dolejskova 2155-3, Prague 18223 8, Czech Republic
关键词
Asolectin; Phospholipid; Paraquat; Sensor; Square wave voltammetry; BILAYER-LIPID MEMBRANES; WAVE VOLTAMMETRIC DETERMINATION; PERFORMANCE LIQUID-CHROMATOGRAPHY; ATOMIC-FORCE MICROSCOPY; DOPED DIAMOND ELECTRODE; PASTE ELECTRODE; MASS-SPECTROMETRY; SENSITIVE DETERMINATION; STRIPPING VOLTAMMETRY; CYCLIC VOLTAMMETRY;
D O I
10.1016/j.jelechem.2017.12.048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical sensor based on glassy carbon electrode modified with asolectin (mixture of soybean phospholipids) was developed. Properties of phospholipid layer, such as thickness and compactness, were investigated using atomic force microscopy and X-ray photoelectron spectroscopy. Phospholipids completely cover whole surface and the thickness of the layer 7.1 +/- 1.2 nm corresponds to the value of the phospholipid bilayer of cell membranes. Due to the accumulation of paraquat in the phospholipid layer, square wave voltammetry with asolectin modified electrode exhibits three times higher sensitivity, measured as a slope of calibration dependence, and better linearity in comparison to unmodified glassy carbon electrode. Limit of detection 2.2 nmol L-1 and recoveries higher than 88% were achieved in model samples of water. The method was used for determination of paraquat in real sample of river water and results were compared with high performance liquid chromatography and differential pulse voltammetry on hanging mercury drop electrode giving 0.071 +/- 0.010, 0.050 +/- 0.010 and 0.061 +/- 0.008 mu mol L-1, respectively.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 50 条
  • [21] A Novel Sensitive Electrochemical Sensor Based on Nickel Chloride Solution Modified Glassy Carbon Electrode for Curcumin Determination
    Zokhtareh, Rosan
    Rahimnejad, Mostafa
    ELECTROANALYSIS, 2018, 30 (05) : 921 - 927
  • [22] Carbon Paste Electrode Modified with Biochar for Sensitive Electrochemical Determination of Paraquat
    Kalinke, Cristiane
    Mangrich, Antonio S.
    Marcolino-Junior, Luiz H.
    Bergamini, Marcio F.
    ELECTROANALYSIS, 2016, 28 (04) : 764 - 769
  • [23] A novel poly(cyanocobalamin) modified glassy carbon electrode as electrochemical sensor for voltammetric determination of peroxynitrite
    Wang, Yan
    Chen, Zhen-zhen
    TALANTA, 2010, 82 (02) : 534 - 539
  • [24] Electrochemical Sensor for Caffeine Based on a Glassy Carbon Electrode Modified with an Attapulgite/Nafion Film
    Tajeu, Kevin Yemele
    Ymele, Ervice
    Jiokeng, Sherman Lesly Zambou
    Tonle, Ignas Kenfack
    ELECTROANALYSIS, 2019, 31 (02) : 350 - 356
  • [25] Electrochemical sensor for epinephrine based on a glassy carbon electrode modified with graphene/gold nanocomposites
    Cui, Fei
    Zhang, Xiaoli
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 669 : 35 - 41
  • [26] An electrochemical sensor based on a modified glassy carbon electrode for detection of epinephrine in the presence of theophylline
    Sarbandian, Zahra
    Beitollahi, Hadi
    ADMET AND DMPK, 2024, 12 (02): : 391 - 402
  • [27] An Electrochemical Sensor Based on Carbon Nano-Fragments and β-cyclodextrin Composite-Modified Glassy Carbon Electrode for the Determination of Rutin
    Zhu, Xiaohua
    Jiao, Qifang
    Zuo, Xiaoxi
    Xiao, Xin
    Liang, Yong
    Nan, Junmin
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2013, 160 (10) : H699 - H703
  • [28] Electrochemical behavior and determination of clozapine on a glassy carbon electrode modified by electrochemical oxidation
    Farhadi, Khalil
    Karimpour, Ahmad
    ANALYTICAL SCIENCES, 2007, 23 (04) : 479 - 483
  • [29] Electrochemical Behavior and Determination of Clozapine on a Glassy Carbon Electrode Modified by Electrochemical Oxidation
    Khalil Farhadc
    Ahmad Karimpour
    Analytical Sciences, 2007, 23 : 479 - 483
  • [30] Optimization of an Electrochemical Sensor for Determination of Imidacloprid Based on -cyclodextrin Electropolymerization on Glassy Carbon Electrode
    Ferreira Oliveira, Ana Elisa
    Bettio, Guilherme Braga
    Pereira, Arnaldo Cesar
    ELECTROANALYSIS, 2018, 30 (09) : 1929 - 1937