An electrochemical sensor based on a modified glassy carbon electrode for detection of epinephrine in the presence of theophylline

被引:15
|
作者
Sarbandian, Zahra [1 ]
Beitollahi, Hadi [2 ]
机构
[1] Grad Univ Adv Technol, Dept Chem, Kerman, Iran
[2] Grad Univ Adv Technol, Inst Sci & High Technol & Environm Sci, Environm Dept, Kerman, Iran
来源
ADMET AND DMPK | 2024年 / 12卷 / 02期
关键词
CeO2-ZnO nanocomposite; voltammetry; sensing platform; modified electrode; REDUCED GRAPHENE OXIDE; FUNCTIONALIZED GRAPHENE; VOLTAMMETRY; ADRENALINE; BEHAVIOR;
D O I
10.5599/admet.2082
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Background and purpose:Neurotransmitters are chemical messengers that enhance and balance signals between cells and target cells in the body. They are vital to the body's ability to function. Epinephrine is one of the most essential catecholamine neurotransmitters withan important biological and pharmacological role in the mammalian central nervous system. Therefore, it is very important to develop sensitive, simple, and fast methods for the determination of this compound. Experimental approach:In the present work, a glassy carbon electrode (GCE) modified with the cerium oxide-zinc oxide (CeO2-ZnO) nanocomposite (CeO2-ZnO/GCE) was developed for the sensitive and quick detection of epinephrine. The CeO2-ZnO nanocomposite was prepared by hydrothermal method. Electrochemical methods such as voltammetry and chronoamperometry techniques were used to investigate the performance of the developed sensor. Key results:The resulting CeO2-ZnO/GCE showed a remarkable response towards the determination of epinephrine. The electrochemical sensor demonstrated a wide dynamic linear range from 0.1to 900.0 mu M for analysis of epinephrine. The LOD equalled 0.03 mu M for epinephrine. In addition, the electrochemical sensor had good feasibility for concurrent detection of epinephrine and theophylline. Furthermore, experimental outputs indicated that the oxidation peaks of epinephrine and theophylline were separated by a 685 mV difference between the two peaks in PBS at a pH of 7.0. Also, an electrochemical sensor has been employed to analyse epinephrine in real samples (urine and epinephrine Injection). Conclusion:The good and acceptable analytical performance of the developed sensor can provide a promising tool for the analysis of epinephrine in real samples .(c) 2024by the authors. This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/)
引用
收藏
页码:391 / 402
页数:12
相关论文
共 50 条
  • [1] Electrochemical sensor for epinephrine based on a glassy carbon electrode modified with graphene/gold nanocomposites
    Cui, Fei
    Zhang, Xiaoli
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 669 : 35 - 41
  • [2] Fabrication of an Electrochemical Sensor for Determination of Epinephrine Using a Glassy Carbon Electrode Modified with Catechol
    Mazloum-Ardakani, Mohammad
    Alvansaz-Yazdi, Farnaz
    Hosseini-Dokht, Farzaneh
    Khoshroo, Alireza
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2023, 10 (04): : 387 - 394
  • [3] Electrochemical Sensing of Theophylline using Modified Glassy Carbon Electrode
    Pour, Effat Sharifi
    Ebrahimi, Maryam
    Beitollahi, Hadi
    CHEMICAL METHODOLOGIES, 2022, 6 (07): : 560 - 568
  • [4] An electrochemical sensor based on octahedral composite modified glassy carbon electrode for voltammetric detection of cocaine
    Oveili, Elham
    Jahani, Shohreh
    Tayari, Omid
    Jahanara, Abbas
    Fazli, Zohreh
    Aramesh-Boroujeni, Zahra
    Rashidi, Soroush
    Baravati, Nadia Rezaei Zade
    Foroughi, Mohammad Mehdi
    ELECTROANALYSIS, 2023, 35 (07)
  • [5] Electrochemical detection of ciprofloxacin based on graphene modified glassy carbon electrode
    Xie, A. -J.
    Chen, Y.
    Luo, S. -P.
    Tao, Y. -W.
    Jin, Y. -S.
    Li, W. -W.
    MATERIALS TECHNOLOGY, 2015, 30 (06) : 362 - 367
  • [6] Electrochemical sensor for the detection of dopamine in the presence of ascorbic acid in neutral pH on graphitized nanoporous carbon modified glassy carbon electrode
    Thangaraj, Rajendiran
    Mufeedah, Muringah Kandy
    Kumar, Annamalai Senthil
    RECENT TRENDS IN ADVANCED MATERIALS, 2012, 584 : 334 - 338
  • [7] Electrochemical Sensor Based on Glassy Carbon Electrode Modified by Palladium Doped ZnO Nanostructures for Glucose Detection
    Yuan, Qingshan
    Zhang, Zunju
    Li, Lei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (06): : 5245 - 5254
  • [8] Electrochemical sensor based on phospholipid modified glassy carbon electrode - determination of paraquat
    Tomkova, H.
    Sokolova, R.
    Opletal, T.
    Kucerova, P.
    Kucera, L.
    Souckova, J.
    Skopalova, J.
    Bartak, P.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 821 : 33 - 39
  • [9] Electrochemical sensor for heparin based on a poly(thionine) modified glassy carbon electrode
    Hong Yu Huo
    Hong Qun Luo
    Nian Bing Li
    Microchimica Acta, 2009, 167 : 195 - 199
  • [10] Electrochemical sensor based on glassy carbon electrode modified with copper vanadate nanobelts for detection of benzoic acid
    Lin, Nan
    Pei, LiZhai
    Wei, Tian
    Liu, HanDing
    Cai, ZhengYu
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2016, 10 (04) : 247 - 252