Renal artery blood flow: quantification with breath-hold or respiratory triggered phase-contrast MR imaging

被引:25
|
作者
de Haan, MW
Kouwenhoven, M
Kessels, AGH
van Engelshoven, JMA
机构
[1] Univ Hosp Maastricht, Dept Diagnost Radiol, NL-6202 AZ Maastricht, Netherlands
[2] Univ Hosp Maastricht, Dept Epidemiol, NL-6202 AZ Maastricht, Netherlands
[3] Philips Med Syst, Dept Clin Sci MR, NL-5680 DA Best, Netherlands
关键词
renal arteries; MR imaging; flow dynamics; phase imaging;
D O I
10.1007/s003300000362
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to evaluate the validity and reproducibility of breath-hold and respiratory triggered phase-contrast (PC) MR imaging techniques in the measurement of renal artery blood flow. Tn 12 healthy subjects cardiac-gated PC flow measurements were obtained in the renal arteries using a breath-hold and a respirarory-triggered technique. The flow measurements were repeated in each renal artery separately. Comparison between the sum of flow measurements in the renal arteries and below the renal arteries served as an internal control. The flow measurements showed a good reproducibility both with the breath-hold (r = 0.92, p < 0.0001) and with the respiratory-triggered (r = 0.91, p < 0.0001) technique. The validity of both methods was good and there was no statistically significant difference. Reproducible quantitative measurements of renal artery blood flow are possible with respiratory controlled, cardiac-gated, PC MR imaging.
引用
收藏
页码:1133 / 1137
页数:5
相关论文
共 50 条
  • [41] Assessment of coronary artery bypass grafts:: Value of different breath-hold MR imaging techniques
    Kalden, P
    Kreitner, KF
    Wittlinger, T
    Voigtländer, T
    Krummenauer, F
    Kestel, J
    Thelen, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) : 1359 - 1364
  • [42] Contrast-enhanced breath-hold MR angiography for evaluating patency of coronary artery bypass grafts
    Vrachliotis, TG
    Bis, KG
    Aliabadi, D
    Shetty, AN
    Safian, R
    Simonetti, O
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (04) : 1073 - 1080
  • [43] Dynamic breath-hold 3D contrast-enhanced renal MR imaging: Comprehensive, time-efficient renal evaluation
    Rofsky, NM
    Weinreb, JC
    Krinsky, GA
    DeCorato, DR
    Earls, JP
    Bosniak, MA
    RADIOLOGY, 1996, 201 : 105 - 105
  • [44] Regularization of flow streamlines in multislice phase-contrast MR imaging
    Fatouraee, N
    Amini, AA
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (06) : 699 - 709
  • [45] Dynamic contrast-enhanced breath-hold MR imaging of thoracic malignancy using cardiac compensation
    Low, RN
    Sigeti, JS
    Song, SYT
    Shimakawa, A
    Pelc, NJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04): : 625 - 631
  • [46] Rapid measurement of renal artery blood flow with ungated spiral phase-contrast MRI
    Park, JB
    Santos, JM
    Hargreaves, BA
    Nayak, KS
    Sommer, G
    Hu, BS
    Nishimura, DG
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (05) : 590 - 595
  • [47] FLOW VELOCITY QUANTIFICATION IN HUMAN CORONARY-ARTERIES WITH FAST, BREATH-HOLD MR-ANGIOGRAPHY
    EDELMAN, RR
    MANNING, WJ
    GERVINO, E
    LI, W
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05): : 699 - 703
  • [48] Phase-contrast MR angiography for detection of arteriosclerotic renal artery stenosis
    Duda, SH
    Schick, F
    Teufl, F
    MullerSchimpfle, M
    Erley, C
    Schneider, W
    Miller, S
    Claussen, CD
    ACTA RADIOLOGICA, 1997, 38 (02) : 287 - 291
  • [49] CAROTID-ARTERY STENOSIS - CLINICAL EFFICACY OF MR PHASE-CONTRAST FLOW QUANTIFICATION AS AN ADJUNCT TO MR-ANGIOGRAPHY
    VANNINEN, RL
    MANNINEN, HI
    PARTANEN, PLK
    VAINIO, PA
    SOIMAKALLIO, S
    RADIOLOGY, 1995, 194 (02) : 459 - 467
  • [50] MEASUREMENT OF NORMAL RENAL-ARTERY BLOOD-FLOW - CINE PHASE-CONTRAST MR-IMAGING VS CLEARANCE OF P-AMINOHIPPURATE
    WOLF, RL
    KING, BF
    TORRES, VE
    WILSON, DM
    EHMAN, RL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (05) : 995 - 1002