Renal artery blood flow: quantification with breath-hold or respiratory triggered phase-contrast MR imaging

被引:25
|
作者
de Haan, MW
Kouwenhoven, M
Kessels, AGH
van Engelshoven, JMA
机构
[1] Univ Hosp Maastricht, Dept Diagnost Radiol, NL-6202 AZ Maastricht, Netherlands
[2] Univ Hosp Maastricht, Dept Epidemiol, NL-6202 AZ Maastricht, Netherlands
[3] Philips Med Syst, Dept Clin Sci MR, NL-5680 DA Best, Netherlands
关键词
renal arteries; MR imaging; flow dynamics; phase imaging;
D O I
10.1007/s003300000362
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to evaluate the validity and reproducibility of breath-hold and respiratory triggered phase-contrast (PC) MR imaging techniques in the measurement of renal artery blood flow. Tn 12 healthy subjects cardiac-gated PC flow measurements were obtained in the renal arteries using a breath-hold and a respirarory-triggered technique. The flow measurements were repeated in each renal artery separately. Comparison between the sum of flow measurements in the renal arteries and below the renal arteries served as an internal control. The flow measurements showed a good reproducibility both with the breath-hold (r = 0.92, p < 0.0001) and with the respiratory-triggered (r = 0.91, p < 0.0001) technique. The validity of both methods was good and there was no statistically significant difference. Reproducible quantitative measurements of renal artery blood flow are possible with respiratory controlled, cardiac-gated, PC MR imaging.
引用
收藏
页码:1133 / 1137
页数:5
相关论文
共 50 条
  • [11] Contribution of early systole to total forward flow volume in breath-hold phase-contrast flow measurements
    Kunz, RP
    Oellig, F
    Krurnmenauer, F
    Oberholzer, K
    Neeb, D
    Vornweg, TW
    Horstick, G
    Kreitner, KF
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (05): : 637 - 645
  • [12] ACCURACY OF QUANTITATIVE FLOW MEASUREMENTS WITH BREATH-HOLD MR IMAGING
    LI, H
    CLARKE, GD
    NESSAIVER, M
    LIU, H
    PESHOCK, RM
    RADIOLOGY, 1992, 185 : 272 - 272
  • [13] Peak blood flow measurement of coronary sinus by cine phase contrast MR imagings: Comparison between breath-hold and respiratory compensation techniques
    Amano, Y
    Nakajima, M
    Kumazaki, T
    CLINICAL IMAGING, 2001, 25 (01) : 23 - 27
  • [14] Breath-hold 3D contrast-enhanced and respiratory-triggered fast spin-echo MR imaging for renal cell carcinoma
    Takahashi, S
    Narumi, Y
    Tsuda, K
    Kim, T
    Furukawa, T
    Nakamura, H
    RADIOLOGY, 1998, 209P : 301 - 301
  • [15] Abdominal phase contrast MR angiography: Breath-hold versus non-breath-hold techniques
    Hara, AK
    Burkart, DJ
    Johnson, CD
    Ehman, RL
    Ilstrup, DM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (01): : 94 - 98
  • [16] Phase-contrast magnetic resonance imaging measurements of cerebral autoregulation with a breath-hold challenge - A feasibility study
    de Boorder, MJ
    Hendrikse, J
    van der Grond, J
    STROKE, 2004, 35 (06) : 1350 - 1354
  • [17] Noninvasive analysis of renal artery blood flow dynamics with MR cine phase-contrast flow measurements
    Schoenberg, SO
    Just, A
    Bock, M
    Knopp, MV
    Persson, PB
    Kirchheim, HR
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1997, 272 (05): : H2477 - H2484
  • [18] MR angiography of the renal artery: comparison of breath-hold two-dimensional phase-contrast cine technique with the phased-array coil and breath-hold two-dimensional time-of-flight technique with the body coil
    Masui, T
    Takehara, Y
    Igarashi, T
    Ichijo, K
    Takahashi, M
    Kaneko, M
    Nozaki, A
    EUROPEAN JOURNAL OF RADIOLOGY, 1997, 25 (01) : 62 - 66
  • [19] Diagnostic performance of contrast-enhanced breath-hold MR imaging in the detection and differentiation of renal lesions
    Krestin, GP
    Hauser, M
    Goehde, SC
    Knecht, M
    HuchBoeni, RA
    Debatin, JF
    RADIOLOGY, 1996, 201 : 104 - 104
  • [20] Renal artery stenosis: Evaluation with breath-hold, three-dimensional, dynamic, gadolinium-enhanced versus three-dimensional, phase-contrast MR angiography
    DeCobelli, F
    Vanzulli, A
    Sironi, S
    Mellone, R
    Angeli, E
    Venturini, M
    Garancini, MP
    Quartagno, R
    Bianchi, G
    DelMaschio, A
    RADIOLOGY, 1997, 205 (03) : 689 - 695