Renal artery blood flow: quantification with breath-hold or respiratory triggered phase-contrast MR imaging

被引:25
|
作者
de Haan, MW
Kouwenhoven, M
Kessels, AGH
van Engelshoven, JMA
机构
[1] Univ Hosp Maastricht, Dept Diagnost Radiol, NL-6202 AZ Maastricht, Netherlands
[2] Univ Hosp Maastricht, Dept Epidemiol, NL-6202 AZ Maastricht, Netherlands
[3] Philips Med Syst, Dept Clin Sci MR, NL-5680 DA Best, Netherlands
关键词
renal arteries; MR imaging; flow dynamics; phase imaging;
D O I
10.1007/s003300000362
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to evaluate the validity and reproducibility of breath-hold and respiratory triggered phase-contrast (PC) MR imaging techniques in the measurement of renal artery blood flow. Tn 12 healthy subjects cardiac-gated PC flow measurements were obtained in the renal arteries using a breath-hold and a respirarory-triggered technique. The flow measurements were repeated in each renal artery separately. Comparison between the sum of flow measurements in the renal arteries and below the renal arteries served as an internal control. The flow measurements showed a good reproducibility both with the breath-hold (r = 0.92, p < 0.0001) and with the respiratory-triggered (r = 0.91, p < 0.0001) technique. The validity of both methods was good and there was no statistically significant difference. Reproducible quantitative measurements of renal artery blood flow are possible with respiratory controlled, cardiac-gated, PC MR imaging.
引用
收藏
页码:1133 / 1137
页数:5
相关论文
共 50 条
  • [21] SEGMENTED TURBOFLASH - METHOD FOR BREATH-HOLD MR IMAGING OF THE LIVER WITH FLEXIBLE CONTRAST
    EDELMAN, RR
    WALLNER, B
    SINGER, A
    ATKINSON, DJ
    SAINI, S
    RADIOLOGY, 1990, 177 (02) : 515 - 521
  • [22] Quantification of hepatic blood flow using a high-resolution phase-contrast MR imaging sequence
    Knight-Greenfield, Ashley
    Dyvorne, Hadrien
    Besa, Cecilia
    Cooper, Nancy
    Schiano, Thomas D.
    Taouli, Bachir
    HEPATOLOGY, 2013, 58 : 961A - 961A
  • [23] MR angiography of the thoracic aorta with an electrocardiographically triggered breath-hold contrast-enhanced sequence
    Arpasi, PJ
    Bis, KG
    Shetty, AN
    White, RD
    Simonetti, OP
    RADIOGRAPHICS, 2000, 20 (01) : 107 - 120
  • [24] Renal artery stenosis: Grading of hemodynamic changes with cine phase-contrast MR blood flow measurements
    Schoenberg, SO
    Knopp, MV
    Bock, M
    Kallinowski, F
    Just, A
    Essig, M
    Hawighorst, H
    Schad, L
    vanKaick, G
    RADIOLOGY, 1997, 203 (01) : 45 - 53
  • [25] PHASE-CONTRAST CINE MR IMAGING FOR MEASURING SUPERIOR MESENTERIC-ARTERY BLOOD-FLOW
    LI, KC
    WHITNEY, WS
    MCDONNELL, CH
    VANDALSEM, WJ
    FREDRICKSON, J
    PELC, NJ
    RADIOLOGY, 1992, 185 : 235 - 235
  • [26] Flow quantification using fast cine phase-contrast MR imaging, conventional cine phase-contrast MR imaging, and Doppler sonography: In vitro and in vivo validation
    Lee, VS
    Spritzer, CE
    Carroll, BA
    Pool, LG
    Bernstein, MA
    Heinle, SK
    MacFall, JR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (04) : 1125 - 1131
  • [27] Quantification of shunt volumes in congenital heart diseases using a breath-hold MR phase contrast technique -: comparison with oximetry
    Petersen, SE
    Voigtländer, T
    Kreitner, KF
    Kalden, P
    Wittlinger, T
    Scharhag, J
    Horstick, G
    Becker, D
    Hommel, G
    Thelen, M
    Meyer, J
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2002, 18 (01): : 53 - 60
  • [28] Quantification of shunt volumes in congenital heart diseases using a breath-hold MR phase contrast technique – comparison with oximetry
    Steffen E. Petersen
    Thomas Voigtländer
    Karl-Friedrich Kreitner
    Peter Kalden
    Thomas Wittlinger
    Jürgen Scharhag
    Georg Horstick
    Dietmar Becker
    Gerhard Hommel
    Manfred Thelen
    Jürgen Meyer
    The International Journal of Cardiovascular Imaging, 2002, 18 : 53 - 60
  • [29] Measurement of ascending aortic flow with view-shared segmented breath-hold cine phase-contrast MRI technique
    Ding, X
    Tkach, JA
    Flamm, SD
    White, RD
    RADIOLOGY, 1998, 209P : 414 - 414
  • [30] Inter breath-hold reproducibility of temporal patterns of coronary artery blood flow
    Stephen Strain
    Jennifer Keegan
    Claire E Raphael
    Robin Simpson
    Malindie H Sugathapala
    Sanjay K Prasad
    David Firmin
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)