Experimental study of a natural draft hybrid (wet/dry) cooling tower with a splash fill type

被引:0
|
作者
Ali, Abdullah Kadhlm [1 ]
Mohammed, Ahmed Qassem [1 ]
Mahdi, Qasim Selah [2 ]
机构
[1] Middle Tech Univ, Engn Tech Coll, Mech Eng Dept IRAQ, Baghdad, Iraq
[2] Mustansiriyah Univ, Mech Engn Dept IRAQ, Coll Engn, Baghdad, Iraq
关键词
cooling range; wet bulb temperature; cooling tower; performance factors; air velocity; splash fill type; heat exchanger; ARTIFICIAL NEURAL-NETWORK; CROSS-WIND; COUNTER-FLOW; PERFORMANCE;
D O I
10.3934/energy.2022031
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Cooling towers have such a significant influence on work and efficiency that researchers and designers are working tirelessly to enhance their performance. A prototype design for a natural draft hybrid (wet/dry) cooling tower has been created, relying on geometrical, dynamic, and thermodynamic similarities. Based on Iraqi weather, experiments have been conducted using splash fill (150 mm) in summer (hot and dry) weather conditions. This study investigated heat transfer mechanisms of both air and water in a natural draft hybrid cooling tower model(NDHCTs), both directly (wet section) and indirectly (dry section). The tower is filled with splash-style packing, and the warm water is spread throughout the building using sprayer nozzles. The influences of water flow rates, fill thickness, and air velocity on the cooling range, approach, cooling capacity, thermal efficiency of the cooling tower, water evaporation loss into the air stream and water loss percentage were explored in this study. The experimental were carried out with four different water flow rates, ranging from 7.5 to 12 (Lpm) litres per minute, and eight different air velocities, all while keeping a constant inlet water temperature and a zero (m/s) crosswind. Data has been gathered, and performance variables have been determined. The findings demonstrate that the cooling tower's efficacy increases when the water flow rate is low, and the cooling range increases with increasing air velocity and decreases with increasing water flow rate; for a 7.5 Lpm water flow rate and a 2.4 m/s air velocity, it expanded to 19.5 degrees C. The cooling capacity increased to 23.2 kW for a water flow rate of 12 Lpm and an air velocity of 2.4 m/s.
引用
收藏
页码:648 / 664
页数:17
相关论文
共 50 条
  • [1] Numerical study of natural draft wet cooling tower
    Zheng Shuihua
    Jin Tai
    Fan Jianren
    MEMS, NANO AND SMART SYSTEMS, PTS 1-6, 2012, 403-408 : 3191 - 3194
  • [2] Investigation on the cooling performance of mechanical draft dry-wet hybrid cooling tower
    Zhao, Cuilin
    Wang, Mingwei
    Gao, Qi
    Cheng, Shen
    He, Suoying
    Zhao, Jifang
    Zhan, Jianwei
    Liu, Zhilan
    Geng, Zhe
    Zhang, Shuzhen
    Qi, Jianhui
    Gao, Ming
    Shi, Yuetao
    APPLIED THERMAL ENGINEERING, 2023, 228
  • [3] Experimental study of cold inflow effect on a small natural draft dry cooling tower
    Li, Xiaoxiao
    Gurgenci, Hal
    Guan, Zhiqiang
    Sun, Yubiao
    APPLIED THERMAL ENGINEERING, 2018, 128 : 762 - 771
  • [4] Natural draft dry cooling tower modelling
    K. Tanimizu
    K. Hooman
    Heat and Mass Transfer, 2013, 49 : 155 - 161
  • [5] Natural draft dry cooling tower modelling
    Tanimizu, K.
    Hooman, K.
    HEAT AND MASS TRANSFER, 2013, 49 (02) : 155 - 161
  • [6] The discussion on cooling optimization of natural draft wet cooling tower
    Ma, L. B.
    Ren, J. X.
    Li, F. Q.
    Zhang, L. J.
    Li, M. Q.
    2018 FIRST INTERNATIONAL CONFERENCE ON ENVIRONMENT PREVENTION AND POLLUTION CONTROL TECHNOLOGY (EPPCT 2018), 2018, 199
  • [7] Investigation on Draft Equation for Natural Draft Dry Cooling Tower
    Sun M.
    Wei H.
    Yang L.
    Du X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2020, 40 (03): : 859 - 866
  • [8] Solar Tower Enhanced Natural Draft Dry Cooling Tower
    Yang, Huiqiang
    Xu, Yan
    Acosta-Iborra, Alberto
    Santana, Domingo
    INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS (SOLARPACES 2016), 2017, 1850
  • [9] Numerical study on performance of hybrid mechanical draft wet cooling tower
    Deng, Weipeng
    Sun, Fengzhong
    Chen, Kun
    Zhang, Xiaoyu
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 201
  • [10] Thermal optimization of a natural draft wet cooling tower
    Williamson, N.
    Behnia, M.
    Armfield, S. W.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (14) : 1349 - 1361