Experimental study of cold inflow effect on a small natural draft dry cooling tower

被引:25
|
作者
Li, Xiaoxiao [1 ]
Gurgenci, Hal [1 ]
Guan, Zhiqiang [1 ]
Sun, Yubiao [1 ]
机构
[1] Univ Queensland, Sch Mech & Min Engn, Brisbane, Qld, Australia
关键词
Cold inflow; Natural draft dry cooling tower; Experimental study; POWER-PLANT; PERFORMANCE; CROSSWIND; SYSTEM; WIND; RECIRCULATION; TEMPERATURE; SIMULATION; CONVECTION; EFFICIENCY;
D O I
10.1016/j.applthermaleng.2017.09.071
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat rejection rate of natural draft dry cooling tower, as well as the operating performance of a power plant, can be affected by numerous ambient factors. The cold inflow is an unfavourable air turbulence at the top of the cooling tower and has a significant negative effect on the performance of natural draft cooling towers. In the present research, results are given for a 20 m high natural draft dry cooling tower experimental system tested at different ambient conditions. Several events of cold air incursion into the top of the cooling tower are identified and the detailed experimental data are presented. The experimental data show that this effect could seriously impair the thermal performance of the cooling tower. The water outlet temperature of the cooling tower has increased by as much as to 3 degrees C in these tests because of the cold inflow effect. The mechanism and the solution are discussed based on the experimental data. The findings in this paper can lay an important foundation for future small natural draft cooling tower design and operation. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:762 / 771
页数:10
相关论文
共 50 条
  • [1] Addressing the adverse cold air inflow effects for a short natural draft dry cooling tower through swirl generation
    Dai, Yuchen
    Kaiser, Antonio S.
    Lu, Yuanshen
    Klimenko, Alexander Y.
    Dong, Peixin
    Hooman, Kamel
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 145
  • [2] Natural draft dry cooling tower modelling
    K. Tanimizu
    K. Hooman
    Heat and Mass Transfer, 2013, 49 : 155 - 161
  • [3] Natural draft dry cooling tower modelling
    Tanimizu, K.
    Hooman, K.
    HEAT AND MASS TRANSFER, 2013, 49 (02) : 155 - 161
  • [4] Investigation on Draft Equation for Natural Draft Dry Cooling Tower
    Sun M.
    Wei H.
    Yang L.
    Du X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2020, 40 (03): : 859 - 866
  • [5] Solar Tower Enhanced Natural Draft Dry Cooling Tower
    Yang, Huiqiang
    Xu, Yan
    Acosta-Iborra, Alberto
    Santana, Domingo
    INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS (SOLARPACES 2016), 2017, 1850
  • [6] Effect of cold inflow on chimney height of natural draft cooling towers
    Chu, Chi-Ming
    Rahman, Md Mizanur
    Kumaresan, Sivakumar
    NUCLEAR ENGINEERING AND DESIGN, 2012, 249 : 125 - 131
  • [7] Full scale experimental study of a small natural draft dry cooling tower for concentrating solar thermal power plant
    Xiaoxiao Li
    Sam Duniam
    Hal Gurgenci
    Zhiqiang Guan
    Anand Veeraragavan
    侯恩哲
    建筑节能, 2017, 45 (05) : 113 - 113
  • [8] Full scale experimental study of a small natural draft dry cooling tower for concentrating solar thermal power plant
    Li, Xiaoxiao
    Duniam, Sam
    Gurgenci, Hal
    Guan, Zhiqiang
    Veeraragavan, Anand
    APPLIED ENERGY, 2017, 193 : 15 - 27
  • [9] Experimental study of a natural draft hybrid (wet/dry) cooling tower with a splash fill type
    Ali, Abdullah Kadhlm
    Mohammed, Ahmed Qassem
    Mahdi, Qasim Selah
    AIMS ENERGY, 2022, 10 (04) : 648 - 664
  • [10] Experimental and numerical analysis of solar enhanced natural draft dry cooling tower
    Xin, Guanglei
    Zhu, Haling
    Jiang, Feng
    Zhao, YangYang
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 89 - 96