Experimental study of cold inflow effect on a small natural draft dry cooling tower

被引:25
|
作者
Li, Xiaoxiao [1 ]
Gurgenci, Hal [1 ]
Guan, Zhiqiang [1 ]
Sun, Yubiao [1 ]
机构
[1] Univ Queensland, Sch Mech & Min Engn, Brisbane, Qld, Australia
关键词
Cold inflow; Natural draft dry cooling tower; Experimental study; POWER-PLANT; PERFORMANCE; CROSSWIND; SYSTEM; WIND; RECIRCULATION; TEMPERATURE; SIMULATION; CONVECTION; EFFICIENCY;
D O I
10.1016/j.applthermaleng.2017.09.071
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat rejection rate of natural draft dry cooling tower, as well as the operating performance of a power plant, can be affected by numerous ambient factors. The cold inflow is an unfavourable air turbulence at the top of the cooling tower and has a significant negative effect on the performance of natural draft cooling towers. In the present research, results are given for a 20 m high natural draft dry cooling tower experimental system tested at different ambient conditions. Several events of cold air incursion into the top of the cooling tower are identified and the detailed experimental data are presented. The experimental data show that this effect could seriously impair the thermal performance of the cooling tower. The water outlet temperature of the cooling tower has increased by as much as to 3 degrees C in these tests because of the cold inflow effect. The mechanism and the solution are discussed based on the experimental data. The findings in this paper can lay an important foundation for future small natural draft cooling tower design and operation. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:762 / 771
页数:10
相关论文
共 50 条
  • [11] Simulation of the UQ Gatton natural draft dry cooling tower
    Li, Xiaoxiao
    Guan, Zhiqiang
    Gurgenci, Hal
    Lu, Yuanshen
    He, Suoying
    APPLIED THERMAL ENGINEERING, 2016, 105 : 1013 - 1020
  • [12] OPERATIONAL BEHAVIOR OF A NATURAL DRAFT DRY COOLING-TOWER
    BUXMANN, J
    BRENNSTOFF-WARME-KRAFT, 1986, 38 (7-8): : 335 - 339
  • [13] Cooling performance of cylinder-frustum natural draft dry cooling tower
    Song, Guoqing
    Zhi, Xudong
    Fan, Feng
    Wang, Wei
    Wang, Peng
    APPLIED THERMAL ENGINEERING, 2020, 180
  • [14] Experimental study of crosswind effects on the performance of small cylindrical natural draft dry cooling towers
    Lu, Yuanshen
    Guan, Zhiqiang
    Gurgenci, Hal
    Hooman, Kamel
    He, Suoying
    Bharathan, Desikan
    ENERGY CONVERSION AND MANAGEMENT, 2015, 91 : 238 - 248
  • [15] Investigations on the influence of nozzle arrangement on the pre-cooling effect for the natural draft dry cooling tower
    Sun, Yubiao
    Guan, Zhiqiang
    Gurgenci, Hal
    Hooman, Kamel
    Li, Xiaoxiao
    APPLIED THERMAL ENGINEERING, 2018, 130 : 979 - 996
  • [16] NATURAL DRAFT COOLING TOWER
    STENNING, AH
    FURZER, I
    INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1969, 8 (04): : 599 - &
  • [17] A study on multi-nozzle arrangement for spray cooling system in natural draft dry cooling tower
    Sun, Yubiao
    Guan, Zhioliang
    Gurgenci, Hal
    Li, Xiaoxiao
    Hooman, Kamel
    APPLIED THERMAL ENGINEERING, 2017, 124 : 795 - 814
  • [18] A Numerical Study on the Improving Techniques of the Cooling Performance of a Natural Draft Dry Cooling Tower under Crosswind
    Wang, Weiliang
    Liu, Pei
    Li, Zheng
    Ni, Weidou
    Liu, Jiangmin
    Li, Yongsheng
    PRES15: PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, 2015, 45 : 1081 - 1086
  • [19] Optimization design of solar enhanced natural draft dry cooling tower
    Zou, Zheng
    Guan, Zhiqiang
    Gurgenci, Hal
    ENERGY CONVERSION AND MANAGEMENT, 2013, 76 : 945 - 955
  • [20] Direct Air Capture via Natural Draft Dry Cooling Tower
    Dong, Peixin
    Li, Xiaoxiao
    Yu, Yuanyuan
    Zhang, Zekun
    Feng, Junjie
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2021, 109