Experimental study of a natural draft hybrid (wet/dry) cooling tower with a splash fill type

被引:0
|
作者
Ali, Abdullah Kadhlm [1 ]
Mohammed, Ahmed Qassem [1 ]
Mahdi, Qasim Selah [2 ]
机构
[1] Middle Tech Univ, Engn Tech Coll, Mech Eng Dept IRAQ, Baghdad, Iraq
[2] Mustansiriyah Univ, Mech Engn Dept IRAQ, Coll Engn, Baghdad, Iraq
关键词
cooling range; wet bulb temperature; cooling tower; performance factors; air velocity; splash fill type; heat exchanger; ARTIFICIAL NEURAL-NETWORK; CROSS-WIND; COUNTER-FLOW; PERFORMANCE;
D O I
10.3934/energy.2022031
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Cooling towers have such a significant influence on work and efficiency that researchers and designers are working tirelessly to enhance their performance. A prototype design for a natural draft hybrid (wet/dry) cooling tower has been created, relying on geometrical, dynamic, and thermodynamic similarities. Based on Iraqi weather, experiments have been conducted using splash fill (150 mm) in summer (hot and dry) weather conditions. This study investigated heat transfer mechanisms of both air and water in a natural draft hybrid cooling tower model(NDHCTs), both directly (wet section) and indirectly (dry section). The tower is filled with splash-style packing, and the warm water is spread throughout the building using sprayer nozzles. The influences of water flow rates, fill thickness, and air velocity on the cooling range, approach, cooling capacity, thermal efficiency of the cooling tower, water evaporation loss into the air stream and water loss percentage were explored in this study. The experimental were carried out with four different water flow rates, ranging from 7.5 to 12 (Lpm) litres per minute, and eight different air velocities, all while keeping a constant inlet water temperature and a zero (m/s) crosswind. Data has been gathered, and performance variables have been determined. The findings demonstrate that the cooling tower's efficacy increases when the water flow rate is low, and the cooling range increases with increasing air velocity and decreases with increasing water flow rate; for a 7.5 Lpm water flow rate and a 2.4 m/s air velocity, it expanded to 19.5 degrees C. The cooling capacity increased to 23.2 kW for a water flow rate of 12 Lpm and an air velocity of 2.4 m/s.
引用
收藏
页码:648 / 664
页数:17
相关论文
共 50 条
  • [41] Performance investigation of the natural draft wet cooling tower at different wet-bulb temperatures
    Raj, Gaurav
    Chandra, Prakash
    Pathak, Piyush Kumar
    International Journal of Ambient Energy, 2022, 43 (01) : 5864 - 5872
  • [42] Experimental Research on the Air Side Flow and Heat Transfer Characteristics of Natural Draft Dry Cooling Tower Cooling Deltas
    Chen T.
    Chen Q.
    Wang L.
    Qin C.
    Li W.
    Han H.
    Zhao Y.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2020, 40 : 188 - 194
  • [43] NUMERICAL SIMULATION OF FLOW FIELDS IN A NATURAL DRAFT WET-COOLING TOWER
    Yang Xiang-liang
    Sun Feng-zhong
    Wang Kai
    Shi Yue-tao
    Wang Nai-hua
    JOURNAL OF HYDRODYNAMICS, 2007, 19 (06) : 762 - 768
  • [44] Numerical investigation on novel water distribution for natural draft wet cooling tower
    Zhou, Xiaohui
    Wang, Weijia
    Chen, Lei
    Yang, Lijun
    Du, Xiaoze
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 181
  • [45] Performance investigation of the natural draft wet cooling tower at different wet-bulb temperatures
    Raj, Gaurav
    Chandra, Prakash
    Pathak, Piyush Kumar
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2021, : 5864 - 5872
  • [46] EVALUATION OF MULTIDIMENSIONAL EFFECT OF NATURAL DRAFT WET-COOLING TOWER FLOW
    Hyhlik, T.
    ENGINEERING MECHANICS 2016, 2016, : 230 - 233
  • [47] Numerical Simulation of Flow Fields in a Natural Draft Wet-Cooling Tower
    Xiang-liang Yang
    Feng-zhong Sun
    Kai Wang
    Yue-tao Shi
    Nai-hua Wang
    Journal of Hydrodynamics, 2007, 19 : 762 - 768
  • [48] CFD TWO-SCALE MODEL OF A WET NATURAL DRAFT COOLING TOWER
    Klimanek, Adam
    Bialecki, Ryszard A.
    Ostrowski, Ziemowit
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2010, 57 (02) : 119 - 137
  • [49] Influence factor analysis of inlet spray on a natural draft wet cooling tower
    Cheng, W.
    Hou, C.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2016, 48 : 177 - 184
  • [50] Concept of CFD model of natural draft wet-cooling tower flow
    Hyhlik, T.
    EFM13 - EXPERIMENTAL FLUID MECHANICS 2013, 2014, 67