Evaluation of a dual chamber implantable cardioverter defibrillator for the treatment of atrial and ventricular arrhythmias

被引:12
|
作者
Boriani, G
Wollmann, C
Biffi, M
Kühl, M
Schuchert, A
Sperzel, J
Stiller, S
Gasparini, G
Böcker, D
机构
[1] Univ Bologna, Inst Cardiol, Policlin S Orsola, I-40138 Bologna, Italy
[2] Univ Munster, Dept Cardiol, D-4400 Munster, Germany
[3] Guidant Inc, St Paul, MN USA
[4] Univ Hamburg, Hamburg, Germany
[5] Univ Ulm, D-89069 Ulm, Germany
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2003年 / 26卷 / 01期
关键词
atrial tachyarrhythmia; atrialftbrillation; implantable cardioverter defibrillator; detection time; cardioversion; defibrillation;
D O I
10.1046/j.1460-9592.2003.00072.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Eighty-nine patients with a documented history of atrial tachyarrhythmias or fibrillation (AF) received a cardioverter defibrillator designed to selectively differentiate and treat atrial and ventricular arrhythmias. Twenty-two patients received a coronary sinus lead and, therefore, could use a separate shock vector for selective treatment of atrial tachyarrhythmias/AE The device is designed to treat tachyarrhythmias with antitachycardia pacing (ATP) and/or shock therapy using an atrial and/or a ventricular shock vector. Patients underwent induction and shock termination of atrial or dual tachyarrhythmias (AF/VF) to verify proper device function and to measure the arrhythmia detection time with enhancements and preventive algorithms programmed On and Off, respectively. Detection time for 329 VF inductions was 2.41 +/- 0.64 seconds with enhancements On and 2.29 +/- 0.47 with enhancements Off (NS). At implant or predischarge, 283 AF and/or AF/VF (121 atrial and 162 atrial/ventricular fibrillation) were induced. Shock conversion efficacy was 89.8% with AF conversion energies ranging from 0.9 to 27 J. Thirteen of the 23 patients had atrial shock conversions using the separate shock vector with an average conversion energy of 1.9 +/- 1.41. (range 0.5-5 J) A During follow-up the efficacy of ATP on atrial tachyarrhythmias was 59% and the efficacy of delivered shocks on AF was 85%. This new dual chamber cardioverter defibrillator appropriately detected and classified atrial arrhythmias, and shock therapy for AF was highly effective. The detection algorithm differentiated atrial tachyarrhythmia/AF and did not delay VF detection. The separate shock vector converted induced AF with energies ranging from 0.6 to 5 J.
引用
收藏
页码:461 / 465
页数:5
相关论文
共 50 条
  • [41] Automatic mode switching of a dual chamber implantable cardioverter-defibrillator induced by a ventricular escape rhythm
    Barold, S. Serge
    Van Heuverswyn, Frederic
    Stroobandt, Roland X.
    JOURNAL OF ELECTROCARDIOLOGY, 2013, 46 (02) : 136 - 139
  • [42] Study of precursors of ventricular tachycardia from data stored in the memory of a dual chamber implantable cardioverter defibrillator
    Leenhardt, A
    Sadoul, N
    Mabo, P
    Kacet, S
    Lavergne, T
    Saoudi, N
    Iscolo, N
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (07): : 1454 - 1460
  • [43] Supraventricular arrhythmias and implantable cardioverter defibrillator shocks in catecholaminergic polymorphic ventricular tachycardia
    Dusi, V.
    De Ferrari, G. M.
    Bos, J. M.
    Moir, C. R.
    Shkolnikova, M.
    Abrams, D. J.
    Crotti, L.
    Wilde, A. A. M.
    Paul, T.
    Eldar, M.
    Till, J.
    Noguer, F. R. I.
    Krahn, A. D.
    Schwartz, P. J.
    Ackerman, M. J.
    EUROPEAN HEART JOURNAL, 2016, 37 : 83 - 83
  • [44] Prevalence of ventricular arrhythmias and role of implantable cardioverter-defibrillator in cardiac amyloidosis
    Bukhari, Syed
    Khan, Bilal
    JOURNAL OF CARDIOLOGY, 2023, 81 (05) : 429 - 433
  • [45] Pharmacological therapy for ventricular arrhythmias in the era of the implantable cardioverter defibrillator: Indispensable or inadvisable?
    Mitchell, LB
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1998, 11 (03) : 235 - 246
  • [46] Successful termination of ventricular arrhythmias with implantable cardioverter defibrillator in a patient with myotonic dystrophy
    Kupo, Peter
    Fodi, Eszter
    Debreceni, Dorottya
    Pal, Endre
    Faludi, Reka
    Tenyi, Dalma
    Molnar, Fanni
    Lovadi, Emese
    Varga, David
    Simor, Tamas
    ORVOSI HETILAP, 2021, 162 (46) : 1856 - 1858
  • [47] IMPLANTABLE AUTOMATIC DEFIBRILLATOR FOR TREATMENT OF MALIGNANT VENTRICULAR ARRHYTHMIAS
    MOWER, MM
    MIROWSKI, M
    REID, PR
    MEDICAL INSTRUMENTATION, 1981, 15 (05): : 325 - 325
  • [48] CURRENT ROLE OF THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IN THE TREATMENT OF LIFE-THREATENING VENTRICULAR ARRHYTHMIAS
    KAY, GN
    PLUMB, VJ
    DAILEY, SM
    EPSTEIN, AE
    AMERICAN JOURNAL OF MEDICINE, 1990, 88 (1N): : N25 - N34
  • [49] Impact of dual chamber pacing on the incidence of atrial and ventricular tachyarrhythmias in recipients of implantable cardioverter defibrillators
    Strohmer, B
    Mermi, J
    Castellanos, E
    Mayr, H
    Gill, J
    Abadia, AA
    Kuehl, M
    Wolpert, C
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 : S249 - S254
  • [50] Ventricular arrhythmias and changes in heart rate preceding ventricular tachycardia in patients with an implantable cardioverter defibrillator
    Claudia Lerma
    Niels Wessel
    Alexander Schirdewan
    Jürgen Kurths
    Leon Glass
    Medical & Biological Engineering & Computing, 2008, 46 : 715 - 727