Evaluation of a dual chamber implantable cardioverter defibrillator for the treatment of atrial and ventricular arrhythmias

被引:12
|
作者
Boriani, G
Wollmann, C
Biffi, M
Kühl, M
Schuchert, A
Sperzel, J
Stiller, S
Gasparini, G
Böcker, D
机构
[1] Univ Bologna, Inst Cardiol, Policlin S Orsola, I-40138 Bologna, Italy
[2] Univ Munster, Dept Cardiol, D-4400 Munster, Germany
[3] Guidant Inc, St Paul, MN USA
[4] Univ Hamburg, Hamburg, Germany
[5] Univ Ulm, D-89069 Ulm, Germany
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2003年 / 26卷 / 01期
关键词
atrial tachyarrhythmia; atrialftbrillation; implantable cardioverter defibrillator; detection time; cardioversion; defibrillation;
D O I
10.1046/j.1460-9592.2003.00072.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Eighty-nine patients with a documented history of atrial tachyarrhythmias or fibrillation (AF) received a cardioverter defibrillator designed to selectively differentiate and treat atrial and ventricular arrhythmias. Twenty-two patients received a coronary sinus lead and, therefore, could use a separate shock vector for selective treatment of atrial tachyarrhythmias/AE The device is designed to treat tachyarrhythmias with antitachycardia pacing (ATP) and/or shock therapy using an atrial and/or a ventricular shock vector. Patients underwent induction and shock termination of atrial or dual tachyarrhythmias (AF/VF) to verify proper device function and to measure the arrhythmia detection time with enhancements and preventive algorithms programmed On and Off, respectively. Detection time for 329 VF inductions was 2.41 +/- 0.64 seconds with enhancements On and 2.29 +/- 0.47 with enhancements Off (NS). At implant or predischarge, 283 AF and/or AF/VF (121 atrial and 162 atrial/ventricular fibrillation) were induced. Shock conversion efficacy was 89.8% with AF conversion energies ranging from 0.9 to 27 J. Thirteen of the 23 patients had atrial shock conversions using the separate shock vector with an average conversion energy of 1.9 +/- 1.41. (range 0.5-5 J) A During follow-up the efficacy of ATP on atrial tachyarrhythmias was 59% and the efficacy of delivered shocks on AF was 85%. This new dual chamber cardioverter defibrillator appropriately detected and classified atrial arrhythmias, and shock therapy for AF was highly effective. The detection algorithm differentiated atrial tachyarrhythmia/AF and did not delay VF detection. The separate shock vector converted induced AF with energies ranging from 0.6 to 5 J.
引用
收藏
页码:461 / 465
页数:5
相关论文
共 50 条
  • [31] Effect of Carvedilol vs Metoprolol on Atrial and Ventricular Arrhythmias Among Implantable Cardioverter-Defibrillator Recipients
    Diamond, Alexander
    Goldenberg, Ilan
    Younis, Arwa
    Goldenberg, Ido
    Sampath, Ramya
    Kutyifa, Valentina
    Chen, Anita Y.
    Mcnitt, Scott
    Polonsky, Bronislava
    Steinberg, Jonathan S.
    Zareba, Wojciech
    Aktas, Mehmet K.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2023, 9 (10) : 2122 - 2131
  • [32] SHOCK WITHOUT WIRES: A LOOK AT SUBCUTANEOUS IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR COMPARED TO TRANSVENOUS IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR FOR VENTRICULAR ARRHYTHMIAS
    Guice, K. C.
    Raja, J.
    Oberoi, M.
    Khouzam, R.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2021, 69 (02) : 493 - 493
  • [33] Shock Without Wires: A Look at Subcutaneous Implantable Cardioverter-Defibrillator Compared to Transvenous Implantable Cardioverter-Defibrillator for Ventricular Arrhythmias
    Raja, Joel
    Guice, Kenneth
    Oberoi, Mansi
    Whitwell, Samantha
    Asbeutah, Abdul Aziz
    Russell, Alex
    Khouzam, Rami N.
    CURRENT PROBLEMS IN CARDIOLOGY, 2022, 47 (09)
  • [34] The treatment of ventricular tachycardias with implantable cardioverter/defibrillator (ICD)
    Beuckelmann, DJ
    HERZ KREISLAUF, 1998, 30 (06): : 195 - 196
  • [35] THE IMPLANTABLE DEFIBRILLATOR IN VENTRICULAR ARRHYTHMIAS
    WINKLE, RA
    HOSPITAL PRACTICE, 1983, 18 (03): : 149 - &
  • [36] COMBINED BIPOLAR DUAL CHAMBER PACING AND AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    RUFFY, R
    LAL, R
    KOUCHOUKOS, NT
    KIM, SS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (04) : 933 - 937
  • [37] Arrhythmia classification with the first dual-chamber implantable cardioverter defibrillator
    Jung, W
    Esmailzadeh, B
    Nitzsche, R
    Wolpert, C
    Luderitz, B
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 7201 - 7201
  • [38] Holter analysis of a dual chamber implantable cardioverter defibrillator detection algorithm
    Olson, WH
    Gunderson, BD
    Gillberg, JM
    Marks, L
    Hubelbank, M
    JOURNAL OF ELECTROCARDIOLOGY, 1997, 30 : 125 - 125
  • [39] A new classification algorithm for discrimination of ventricular from supraventricular tachycardia in a dual chamber implantable cardioverter defibrillator
    Korte, T
    Jung, W
    Wolpert, C
    Spehl, S
    Schumacher, B
    Esmailzadeh, B
    Lüderitz, B
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (01) : 70 - 73
  • [40] Delayed detection of stable ventricular tachycardia in a dual-chamber implantable cardioverter defibrillator: What is the mechanism?
    Strohmer, B
    Schernthaner, C
    Pichler, M
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (02) : 244 - 246