Evaluation of a dual chamber implantable cardioverter defibrillator for the treatment of atrial and ventricular arrhythmias

被引:12
|
作者
Boriani, G
Wollmann, C
Biffi, M
Kühl, M
Schuchert, A
Sperzel, J
Stiller, S
Gasparini, G
Böcker, D
机构
[1] Univ Bologna, Inst Cardiol, Policlin S Orsola, I-40138 Bologna, Italy
[2] Univ Munster, Dept Cardiol, D-4400 Munster, Germany
[3] Guidant Inc, St Paul, MN USA
[4] Univ Hamburg, Hamburg, Germany
[5] Univ Ulm, D-89069 Ulm, Germany
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2003年 / 26卷 / 01期
关键词
atrial tachyarrhythmia; atrialftbrillation; implantable cardioverter defibrillator; detection time; cardioversion; defibrillation;
D O I
10.1046/j.1460-9592.2003.00072.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Eighty-nine patients with a documented history of atrial tachyarrhythmias or fibrillation (AF) received a cardioverter defibrillator designed to selectively differentiate and treat atrial and ventricular arrhythmias. Twenty-two patients received a coronary sinus lead and, therefore, could use a separate shock vector for selective treatment of atrial tachyarrhythmias/AE The device is designed to treat tachyarrhythmias with antitachycardia pacing (ATP) and/or shock therapy using an atrial and/or a ventricular shock vector. Patients underwent induction and shock termination of atrial or dual tachyarrhythmias (AF/VF) to verify proper device function and to measure the arrhythmia detection time with enhancements and preventive algorithms programmed On and Off, respectively. Detection time for 329 VF inductions was 2.41 +/- 0.64 seconds with enhancements On and 2.29 +/- 0.47 with enhancements Off (NS). At implant or predischarge, 283 AF and/or AF/VF (121 atrial and 162 atrial/ventricular fibrillation) were induced. Shock conversion efficacy was 89.8% with AF conversion energies ranging from 0.9 to 27 J. Thirteen of the 23 patients had atrial shock conversions using the separate shock vector with an average conversion energy of 1.9 +/- 1.41. (range 0.5-5 J) A During follow-up the efficacy of ATP on atrial tachyarrhythmias was 59% and the efficacy of delivered shocks on AF was 85%. This new dual chamber cardioverter defibrillator appropriately detected and classified atrial arrhythmias, and shock therapy for AF was highly effective. The detection algorithm differentiated atrial tachyarrhythmia/AF and did not delay VF detection. The separate shock vector converted induced AF with energies ranging from 0.6 to 5 J.
引用
收藏
页码:461 / 465
页数:5
相关论文
共 50 条
  • [1] Importance of the atrial channel for ventricular arrhythmia therapy in the dual chamber implantable cardioverter defibrillator
    Dijkman, B
    Wellens, HJJ
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (12) : 1309 - 1319
  • [2] Efficacy of pacing therapies for treating atrial tachyarrhythmias in patients with ventricular arrhythmias receiving a dual-chamber implantable cardioverter defibrillator
    Adler, SW
    Wolpert, C
    Warman, EN
    Musley, SK
    Koehler, JL
    Euler, DE
    CIRCULATION, 2001, 104 (08) : 887 - 892
  • [3] TREATMENT OF MALIGNANT VENTRICULAR ARRHYTHMIAS WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    SLATER, AD
    SINGER, I
    STAVENS, CS
    ZEECHENG, C
    GANZEL, BL
    KUPERSMITH, J
    MAVROUDIS, C
    GRAY, LA
    ANNALS OF SURGERY, 1989, 209 (05) : 635 - 641
  • [4] Diagnosis and therapy of atrial tachyarrhythmias in the dual chamber implantable cardioverter defibrillator
    Dijkman, B
    Wellens, HJJ
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (11) : 1196 - 1205
  • [5] The efficacy of pacing therapies for treating atrial tachyarrhythmias in patients with ventricular arrhythmias receiving a dual-chamber implantable cardioverter-defibrillator
    Adler, SW
    Wolpert, C
    Warman, EN
    Musley, SK
    Koehler, JL
    Euler, DE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 95A - 95A
  • [6] Use of atrial and ventricular electrograms from a dual chamber implantable cardioverter defibrillator to elucidate a complex dysrhythmia
    Greenberg, RM
    Degeratu, FT
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (10): : 2002 - 2004
  • [7] Implantable dual-chamber defibrillator for the selective treatment of spontaneous atrial and ventricular arrhythmias:: Arrhythmia incidence and device performance
    Schuchert, A
    Boriani, G
    Wollmann, C
    Biffi, M
    Kühl, M
    Sperzel, J
    Stiller, S
    Gasparini, G
    Böcker, D
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2005, 12 (02) : 149 - 156
  • [8] Implantable Dual-Chamber Defibrillator for the Selective Treatment of Spontaneous Atrial and Ventricular Arrhythmias: Arrhythmia Incidence and Device Performance
    Andreas Schuchert
    Giuseppe Boriani
    Christian Wollmann
    Mauro Biffi
    Martin Kühl
    Johannes Sperzel
    Sascha Stiller
    Gianni Gasparini
    Dirk Böcker
    Journal of Interventional Cardiac Electrophysiology, 2005, 12 : 149 - 156
  • [9] Drugs for ventricular arrhythmias in the era of the implantable cardioverter defibrillator
    Peters, NS
    EUROPEAN HEART JOURNAL, 1999, 20 (05) : 321 - 323
  • [10] Dual-chamber implantable cardioverter defibrillator vs single-chamber implantable cardioverter defibrillator: High incidence of device and lead related complications in dual-chamber implantable cardioverter defibrillator
    Takahashi, T
    Cannom, DS
    Abdullah, E
    Lerman, RD
    Park, Y
    Bishara, M
    Girsky, M
    Bhandari, AK
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 127A - 127A