Verification of high dose rate 192Ir source position during brachytherapy treatment

被引:16
|
作者
Batic, M. [1 ]
Burger, J. [2 ]
Cindro, V. [1 ]
Kramberger, G. [1 ]
Mandic, I. [1 ]
Mikuz, M. [1 ,3 ]
Studen, A. [1 ]
Zavrtanik, M. [1 ]
机构
[1] Jozef Stefan Inst, Expt Particle Phys Dept, Ljubljana, Slovenia
[2] Inst Oncol, Dept Radiophys, Ljubljana, Slovenia
[3] Univ Ljubljana, Dept Phys, Ljubljana 61000, Slovenia
关键词
Source localization; Brachytherapy; Silicon pixel detectors; Verification; CAMERA;
D O I
10.1016/j.nima.2009.09.122
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A system for in vivo tracking of 1 Ci Ir-192 source during brachytherapy treatment has been built using high resistivity silicon pad detectors as image sensors and knife-edge lead pinholes as collimators. The sensors consist of 256 pads arranged in 32 x 8 grid with pad size 1.4 x 1.4 mm(2) and 1 mm thickness. The sensors have two metal layers, enabling connection of readout electronics (VATAGP3_1 chips) at the edge of the detector. With source self-images obtained from a dual-pinhole system, location of the source can be reconstructed in three dimensions in real time, allowing on-line detection of deviations from planned treatment. The system was tested with 1 Ci Ir-192 clinical source in air and plexi-glass phantom. The movements of the source could be tracked in a field of view of approximately 20 x 20 x 20 cm(3) with absolute precision of about 5 mm. Positions of the source, relative to the first measured source position, could be mapped with precision of around 3 mm. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:206 / 208
页数:3
相关论文
共 50 条
  • [1] Verification of High Dose Rate 192Ir Source Position During Brachytherapy Treatment Using Silicon Pixel Detectors
    Batic, Matej
    Burger, Janez
    Cindro, Vladimir
    Kramberger, Gregor
    Mandic, Igor
    Mikuz, Marko
    Studen, Andrej
    Zavrtanik, Marko
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (05) : 2250 - 2256
  • [2] A technique for calibrating a high dose rate 192Ir brachytherapy source
    Fourie, O. L.
    Crabtree, T. G.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (01) : 85 - 92
  • [3] A technique for calibrating a high dose rate 192Ir brachytherapy source
    O. L. Fourie
    T. G. Crabtree
    Australasian Physical & Engineering Sciences in Medicine, 2012, 35 : 85 - 92
  • [4] A system for localization of high dose rate 192Ir source during brachytherapy treatment with silicon detectors
    Batic, Matej
    Burger, Janez
    Cindro, Vladimir
    Kramberger, Gregor
    Mandic, Igor
    Mikuz, Marko
    Studen, Andrej
    Zavrtanik, Marko
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3794 - +
  • [5] High-Dose-Rate 192Ir Brachytherapy Dose Verification: A Phantom Study
    Nikoofar, Alireza
    Hoseinpour, Zohreh
    Mahdavi, Seied Rabi
    Hasanzadeh, Hadi
    Tavirani, Mostafa Rezaei
    IRANIAN JOURNAL OF CANCER PREVENTION, 2015, 8 (03)
  • [6] Dosimetric characteristics of the 192Ir high-dose-rate afterloading brachytherapy source
    Sadeghi, Mahdi
    Taghdiri, Fatemah
    Saidi, Pooneh
    JAPANESE JOURNAL OF RADIOLOGY, 2011, 29 (05) : 324 - 329
  • [7] Dosimetric characteristics of the 192Ir high-dose-rate afterloading brachytherapy source
    Mahdi Sadeghi
    Fatemah Taghdiri
    Pooneh Saidi
    Japanese Journal of Radiology, 2011, 29 : 324 - 329
  • [8] Monte Carlo dosimetry of the IRAsource high dose rate 192Ir brachytherapy source
    Sarabiasl, Akbar
    Ayoobian, Navid
    Jabbari, Iraj
    Poorbaygi, Hossein
    Javanshir, Mohammad Reza
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (02) : 413 - 422
  • [9] Calibration of 192Ir High Dose Rate Brachytherapy Source Using Water Phantom
    Yu, L.
    Yang, B.
    Liu, X.
    Pang, T.
    Liu, N.
    Li, B.
    Dong, T.
    Wang, B.
    Wang, Z.
    Qiu, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E212 - E212
  • [10] Small dimension plastic dosimeter in High Dose Rate Brachytherapy with 192Ir source
    Rego, Florbela
    Ribeiro, Tiago Ramos
    Peralta, Luis
    Jesus, Carlos
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 249 - 252