Odontoid plate fixation without C1-C2 arthrodesis: Biomechanical testing of a novel surgical technique and comparison to the conventional screw fixation procedure

被引:5
|
作者
Platzer, Patrick [1 ]
Eipeldauer, Stefan [1 ]
Vecsei, Vilmos [1 ]
机构
[1] Med Univ Vienna, Dept Trauma Surg, A-1090 Vienna, Austria
关键词
Odontoid fractures; Plate fixation; Biomechanical testing; FRACTURES; STABILIZATION;
D O I
10.1016/j.clinbiomech.2010.03.012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Odontoid plate fixation without C1-C2 arthrodesis appears to be a practicable option for the management of odontoid fractures that are not amenable for conventional screw fixation. The purpose of this study was to measure the mechanical stability of odontoid plate fixation using a specially designed plate construct, and to compare the results to those after conventional screw fixation. Methods: The second cervical vertebra was removed from twenty fresh human spinal columns. Stiffness and failure load of the intact odontoid were measured, and type II odontoid fractures were created. Afterward, the specimens were randomly assigned to one of the following four groups: Group I: plate-fixation; Group II: 2-AO-screw-fixation; Group III: 1-AO-screw-fixation; Group IV: Herbert-screw-fixation. In a second series, stiffness and failure load of the stabilized odontoid fractures were assessed for comparison and statistical analysis. Findings: Group I showed a significantly higher mean failure load than the other groups. The mean failure load of Group I after fixation of the odontoid fracture was 86% of the mean failure load of the intact odontoid. Comparing Groups II, III and IV. there was no significant difference regarding the failure load. In these three groups the mean failure load after odontoid fixation was approximately 50% of the mean failure load of the intact odontoid. Interpretation: Odontoid plate fixation as an alternative procedure in certain fracture patterns provided a significantly higher biomechanical stability than the technique of odontoid screw fixation. Using a specially designed plate construct, 86% of the original stability of the intact odontoid was restored. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:623 / 627
页数:5
相关论文
共 50 条
  • [41] A meta-analysis of the fusion rate from surgical treatment for odontoid factures: anterior odontoid screw versus posterior C1-C2 arthrodesis
    Shen, Ye
    Miao, Jinhao
    Li, Chao
    Fang, Lei
    Cao, Samantha
    Zhang, Ming
    Yan, Jianhua
    Kuang, Yong
    EUROPEAN SPINE JOURNAL, 2015, 24 (08) : 1649 - 1657
  • [42] Clinical and radiological Comparison of treatment of atlantoaxial instability by posterior C1-C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation
    Lee, Sun-Ho
    Kim, Eun Sang
    Sung, Joo-Kyung
    Park, Yeun-Mook
    Eoh, Whan
    JOURNAL OF CLINICAL NEUROSCIENCE, 2010, 17 (07) : 886 - 892
  • [43] Computer-assisted C1-C2 Transarticular Screw Fixation "Magerl Technique" for Atlantoaxial Instability
    Uehara, Masashi
    Takahashi, Jun
    Hirabayashi, Hiroki
    Hashidate, Hiroyuki
    Ogihara, Nobuhide
    Mukaiyama, Keijiro
    Kato, Hiroyuki
    ASIAN SPINE JOURNAL, 2012, 6 (03) : 168 - 177
  • [44] Results of C1-C2 transarticular screw fixation in a series of 20 patients
    Arráez, MA
    NEUROCIRUGIA, 2002, 13 (06): : 436 - 436
  • [45] Aggregatibacter aphrophilus ventriculitis following C1-C2 transarticular screw fixation
    Tok, Sina
    Neidert, Marian Christoph
    Bloemberg, Guido
    Sueruecue, Oguzkan
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2016, 50 (01) : 63 - 68
  • [46] Accurate and Simple Screw Insertion Procedure With Patient-Specific Screw Guide Templates for Posterior C1-C2 Fixation
    Sugawara, Taku
    Higashiyama, Naoki
    Kaneyama, Shuichi
    Sumi, Masatoshi
    SPINE, 2017, 42 (06) : E340 - E346
  • [47] Biomechanical comparison of a novel C1 posterior U-construct with four other techniques in a C1-C2 fixation model
    Herzog, Joshua P.
    Zarkadis, Nicholas J.
    Prabhakar, Gautham
    Kusnezov, Nicholas A.
    JOURNAL OF ORTHOPAEDICS, 2018, 15 (02) : 741 - 745
  • [48] Modification of C1-C2 transarticular screw fixation by image-guided surgery
    Weidner, A
    Wähler, M
    Chiu, ST
    Ullrich, CG
    SPINE, 2000, 25 (20) : 2668 - 2673
  • [49] C1-C2 intra-articular screw fixation for atlantoaxial posterior stabilization
    Tokuhashi, Y
    Matsuzaki, H
    Shirasaki, Y
    Tateishi, T
    SPINE, 2000, 25 (03) : 337 - 341
  • [50] Posterior C1-C2 screw-rod fixation and autograft fusion for the treatment of os odontoideum with C1-C2 instability
    Huang, Da-Geng
    Wang, Tao
    Hao, Ding-Jun
    He, Bao-Rong
    Liu, Tuan-Jiang
    Ma, Xiao-Wen
    Yu, Cheng-Cheng
    Feng, Hang
    Zhao, Song-Chum
    Hui, Hua
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2017, 163 : 71 - 75