Odontoid plate fixation without C1-C2 arthrodesis: Biomechanical testing of a novel surgical technique and comparison to the conventional screw fixation procedure

被引:5
|
作者
Platzer, Patrick [1 ]
Eipeldauer, Stefan [1 ]
Vecsei, Vilmos [1 ]
机构
[1] Med Univ Vienna, Dept Trauma Surg, A-1090 Vienna, Austria
关键词
Odontoid fractures; Plate fixation; Biomechanical testing; FRACTURES; STABILIZATION;
D O I
10.1016/j.clinbiomech.2010.03.012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Odontoid plate fixation without C1-C2 arthrodesis appears to be a practicable option for the management of odontoid fractures that are not amenable for conventional screw fixation. The purpose of this study was to measure the mechanical stability of odontoid plate fixation using a specially designed plate construct, and to compare the results to those after conventional screw fixation. Methods: The second cervical vertebra was removed from twenty fresh human spinal columns. Stiffness and failure load of the intact odontoid were measured, and type II odontoid fractures were created. Afterward, the specimens were randomly assigned to one of the following four groups: Group I: plate-fixation; Group II: 2-AO-screw-fixation; Group III: 1-AO-screw-fixation; Group IV: Herbert-screw-fixation. In a second series, stiffness and failure load of the stabilized odontoid fractures were assessed for comparison and statistical analysis. Findings: Group I showed a significantly higher mean failure load than the other groups. The mean failure load of Group I after fixation of the odontoid fracture was 86% of the mean failure load of the intact odontoid. Comparing Groups II, III and IV. there was no significant difference regarding the failure load. In these three groups the mean failure load after odontoid fixation was approximately 50% of the mean failure load of the intact odontoid. Interpretation: Odontoid plate fixation as an alternative procedure in certain fracture patterns provided a significantly higher biomechanical stability than the technique of odontoid screw fixation. Using a specially designed plate construct, 86% of the original stability of the intact odontoid was restored. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:623 / 627
页数:5
相关论文
共 50 条
  • [31] Anatomic suitability of the C1-C2 complex for pedicle screw fixation
    Resnick, DK
    Lapsiwala, S
    Trost, GR
    SPINE, 2002, 27 (14) : 1494 - 1498
  • [32] Virtual placement of posterior C1-C2 transarticular screw fixation
    Peter Spangenberg
    Volker Coenen
    Joachim Michael Gilsbach
    Veit Rohde
    Neurosurgical Review, 2006, 29 : 114 - 117
  • [33] Posterior C1-C2 fusion with polyaxial screw and rod fixation
    Harms, J
    Melcher, RP
    SPINE, 2001, 26 (22) : 2467 - 2471
  • [34] C1-C2 transarticular screw fixation for atlantoaxial instability: A 6-year experience, and C1-C2 transarticular screw fixation-technical aspects - Reply
    Haid, RW
    Rodts, GE
    Subach, B
    NEUROSURGERY, 2002, 50 (05) : 1166 - 1166
  • [35] C1-C2 Posterior Fixation: Indications, Technique, and Results
    Jacobson, Mark E.
    Khan, Safdar N.
    An, Howard S.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2012, 43 (01) : 11 - +
  • [36] Percutaneous anterior C1/2 transarticular screw fixation: salvage of failed percutaneous odontoid screw fixation for odontoid fracture
    Ai-Min Wu
    Hai-Ming Jin
    Zhong-Ke Lin
    Yong-Long Chi
    Xiang-Yang Wang
    Journal of Orthopaedic Surgery and Research, 12
  • [37] Percutaneous anterior C1/2 transarticular screw fixation: salvage of failed percutaneous odontoid screw fixation for odontoid fracture
    Wu, Ai-Min
    Jin, Hai-Ming
    Lin, Zhong-Ke
    Chi, Yong-Long
    Wang, Xiang-Yang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
  • [38] Retro-odontoid cystic mass treated by laminectomy and C1-C2 fixation
    Lin, Dasheng
    Ding, Zhenqi
    Guo, Yanjie
    Lian, Kejian
    INDIAN JOURNAL OF ORTHOPAEDICS, 2014, 48 (06) : 621 - 624
  • [39] Retro-odontoid cystic mass treated by laminectomy and C1-C2 fixation
    Dasheng Lin
    Zhenqi Ding
    Yanjie Guo
    Kejian Lian
    Indian Journal of Orthopaedics, 2014, 48 : 621 - 624
  • [40] Atlantoaxial fusion using anterior transarticular screw fixation of C1-C2: technical innovation and biomechanical study
    Sen, MK
    Steffen, T
    Beckman, L
    Tsantrizos, A
    Reindl, R
    Aebi, M
    EUROPEAN SPINE JOURNAL, 2005, 14 (05) : 512 - 518