Adsorptive anodic stripping voltammetric determination of antimony(III) on a glassy carbon electrode using rivastigmine as a new chemical receptor

被引:15
|
作者
Sezgin, Hanife Vardar [1 ]
Gokcel, H. Ismet [1 ]
Dilgin, Yusuf [2 ]
机构
[1] Ege Univ, Fac Sci, Dept Chem, TR-35100 Izmir, Turkey
[2] Canakkale Onsekiz Mart Univ, Sci & Art Fac, Dept Chem, TR-17100 Canakkale, Turkey
来源
关键词
Rivastigmine; Antimony(III) determination; Stripping voltammetry; Glassy carbon electrode; INORGANIC ANTIMONY; ELECTROCHEMICAL SENSORS; TRACE ANTIMONY; FILM; SPECIATION; SEAWATER; SB(III); CHRONOPOTENTIOMETRY; PRECONCENTRATION; MOLYBDENUM(VI);
D O I
10.1016/j.snb.2014.12.029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A very simple and sensitive adsorptive anodic stripping voltammetric method was developed for determination of antimony(III) on a glassy carbon electrode (GCE), using rivastigmine (RIV) as the chemical receptor. No study on the usage of antimony(III) for metal determination as a modifier/complexing agent/chemical receptor was found in the literature review. The proposed method is based on the accumulation of the Sb-RIV complex on GCE under stirring conditions using optimized accumulation potential and time following the recording of a differential pulse (DP) voltammogram in anodic direction. The calibration graph consisted of two linear segments of 5.0 x 10(-4)-0.5 mu M (i(p)(mu A) = 7.45C(Sb(III)) (mu M) + 0.05, R-2 = 0.9974) and 0.5-2.5 mu M (i(p)(mu A) = 10.45C(Sb(III)) (mu M) - 0.76, R-2 = 0.9959) with a detection limit of 7.1 x 10(-11) mol L-1. The RSD (n = 5, intra-day) for 1.0 x 10(-6) mol L-1 Sb(III) and 5.0 x 10(-7) mol L-1 Sb(III) were calculated as 1.53% and 2.62%, respectively. Inter-day precision (n = 5) was also calculated as 2.16% for 1.0 x 10(-6) mol L-1 Sb(III), indicating that the proposed method has good precision. The spiked water sample analyses were evaluated using the described method and a good recovery of Sb(III) was obtained with results in the range from 95.0% to 97.6%. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:686 / 694
页数:9
相关论文
共 50 条
  • [1] Anodic Adsorptive Stripping Voltammetric Determination of Rafoxanide on Glassy Carbon Electrode
    Radi, Abd-elgawad
    El-samboskany, Hassan
    COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2020, 23 (10) : 1002 - 1009
  • [2] Adsorptive stripping voltammetric determination of erythromycin at a pretreated glassy carbon electrode
    Wang, HS
    Zhang, AM
    Cui, H
    Liu, DJ
    Liu, RM
    MICROCHEMICAL JOURNAL, 2000, 64 (01) : 67 - 71
  • [3] Determination of triclocarban by direct and adsorptive stripping voltammetric methods on a glassy carbon electrode
    Lacerda Martins Lucio, Maria Monica
    Rolim Severo, Flaviana Justino
    Estevam da Costa, Daniel Jackson
    Lourenco, Anabel Santos
    Ribeiro, Williame Farias
    Bichinho, Katia Messias
    Ugulino de Araujo, Mario Cesar
    ANALYTICAL METHODS, 2015, 7 (07) : 3268 - 3276
  • [4] Anodic stripping voltammetric determination of gold on a polyvinylferrocene coated glassy carbon electrode
    Kavanoz, M
    Gülce, H
    Yildiz, A
    TURKISH JOURNAL OF CHEMISTRY, 2004, 28 (03) : 287 - 297
  • [5] Adsorptive Stripping Voltammetric Determination of Azithromycin at a Glassy Carbon Electrode Modified by Electrochemical Oxidation
    Biljana Nigović
    Analytical Sciences, 2004, 20 : 639 - 643
  • [6] Adsorptive stripping voltammetric determination of azithromycin at a glassy carbon electrode modified by electrochemical oxidation
    Nigovic, B
    ANALYTICAL SCIENCES, 2004, 20 (04) : 639 - 643
  • [7] Anodic stripping voltammetric determination of arsenic(III) using a glassy carbon electrode modified with gold-palladium bimetallic nanoparticles
    Lan, Yuecun
    Luo, Hanjin
    Ren, Xiaohui
    Wang, Yiping
    Liu, Yuze
    MICROCHIMICA ACTA, 2012, 178 (1-2) : 153 - 161
  • [8] Anodic stripping voltammetric determination of arsenic(III) using a glassy carbon electrode modified with gold-palladium bimetallic nanoparticles
    Yuecun Lan
    Hanjin Luo
    Xiaohui Ren
    Yiping Wang
    Yuze Liu
    Microchimica Acta, 2012, 178 : 153 - 161
  • [9] Adsorptive Voltammetric Determination of Nimesulide at Glassy Carbon Electrode
    El-Sayed, Gamal O.
    Yasin, Shalaby A.
    El Ries, Mohammed A.
    El-Badawy, Azza A.
    LATIN AMERICAN JOURNAL OF PHARMACY, 2009, 28 (05): : 741 - 746
  • [10] Adsorptive voltammetric determination of orthophosphate at a glassy carbon electrode
    Tanaka, T
    Miura, M
    Ishiyama, T
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 2001, 19 (04): : 591 - 599