Adsorptive anodic stripping voltammetric determination of antimony(III) on a glassy carbon electrode using rivastigmine as a new chemical receptor

被引:15
|
作者
Sezgin, Hanife Vardar [1 ]
Gokcel, H. Ismet [1 ]
Dilgin, Yusuf [2 ]
机构
[1] Ege Univ, Fac Sci, Dept Chem, TR-35100 Izmir, Turkey
[2] Canakkale Onsekiz Mart Univ, Sci & Art Fac, Dept Chem, TR-17100 Canakkale, Turkey
来源
关键词
Rivastigmine; Antimony(III) determination; Stripping voltammetry; Glassy carbon electrode; INORGANIC ANTIMONY; ELECTROCHEMICAL SENSORS; TRACE ANTIMONY; FILM; SPECIATION; SEAWATER; SB(III); CHRONOPOTENTIOMETRY; PRECONCENTRATION; MOLYBDENUM(VI);
D O I
10.1016/j.snb.2014.12.029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A very simple and sensitive adsorptive anodic stripping voltammetric method was developed for determination of antimony(III) on a glassy carbon electrode (GCE), using rivastigmine (RIV) as the chemical receptor. No study on the usage of antimony(III) for metal determination as a modifier/complexing agent/chemical receptor was found in the literature review. The proposed method is based on the accumulation of the Sb-RIV complex on GCE under stirring conditions using optimized accumulation potential and time following the recording of a differential pulse (DP) voltammogram in anodic direction. The calibration graph consisted of two linear segments of 5.0 x 10(-4)-0.5 mu M (i(p)(mu A) = 7.45C(Sb(III)) (mu M) + 0.05, R-2 = 0.9974) and 0.5-2.5 mu M (i(p)(mu A) = 10.45C(Sb(III)) (mu M) - 0.76, R-2 = 0.9959) with a detection limit of 7.1 x 10(-11) mol L-1. The RSD (n = 5, intra-day) for 1.0 x 10(-6) mol L-1 Sb(III) and 5.0 x 10(-7) mol L-1 Sb(III) were calculated as 1.53% and 2.62%, respectively. Inter-day precision (n = 5) was also calculated as 2.16% for 1.0 x 10(-6) mol L-1 Sb(III), indicating that the proposed method has good precision. The spiked water sample analyses were evaluated using the described method and a good recovery of Sb(III) was obtained with results in the range from 95.0% to 97.6%. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:686 / 694
页数:9
相关论文
共 50 条
  • [31] Anodic Stripping Voltammetric Determination of Lead(II) Using Glassy Carbon Electrode Modified with Novel Calix[4]arene
    吕鉴泉
    何锡文
    曾宪顺
    张海丽
    张正之
    Chinese Journal of Chemistry, 2003, (06) : 687 - 692
  • [32] Adsorptive Stripping Voltammetric Determination of Antimony by Using Alizarin Red S
    Nakibolu, Nuri
    Sahin, Ibrahim
    Ertas, F. Nil
    ANALYTICAL LETTERS, 2008, 41 (14) : 2621 - 2633
  • [33] Pulse anodic stripping voltammetric determination of copper with an amoxicillin-nafion modified glassy carbon electrode
    Ramadan, A. A.
    Mandil, H.
    Saleh, M. A.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2008, 38 (12) : 1715 - 1720
  • [34] ANODIC-STRIPPING VOLTAMMETRIC DETERMINATION OF ARSENIC AT A COPPER-COATED GLASSY-CARBON ELECTRODE
    JAYA, S
    RAO, TP
    RAO, GP
    TALANTA, 1987, 34 (06) : 574 - 576
  • [35] Multiwall Carbon Nanotubes-modified Glassy Carbon Electrode for Square-wave Stripping Voltammetric Determination of Aqueous Antimony (III) ion
    Guo, Yaoguang
    Yan, Wei
    Lou, Xiaoyi
    Xiao, Dongxue
    Zhai, Ping
    Zhao, Guangchao
    Zhang, Wugang
    Huang, Peng
    Wang, Zhaohui
    Liu, Jianshe
    ADVANCES IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-6, 2012, 518-523 : 1571 - +
  • [36] Anodic stripping voltammetric determination of thallium(III) using a Tosflex/mercury film electrode
    Lu, TH
    Sun, IW
    ELECTROANALYSIS, 1998, 10 (15) : 1052 - 1056
  • [37] Determination of trace amount of bismuth(III) by adsorptive anodic stripping voltammetry at carbon paste electrode
    Guo, HS
    Li, YH
    Xiao, PF
    He, NY
    ANALYTICA CHIMICA ACTA, 2005, 534 (01) : 143 - 147
  • [38] Adsorptive Stripping Voltammetric Determination of Cobalt (II) on the Carbon Paste Electrode
    Mohadesi, Alireza
    Teimoori, Elham
    Taher, Mohammad Ali
    Beitollah, Hadis
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (02): : 301 - 308
  • [39] Adsorptive stripping voltammetric determination of Tetracycline in pharmaceutical capsule formulation using Poly(Malachite green) modified glassy carbon electrode
    Turbale, Mahilet
    Moges, Amsalu
    Dawit, Mulugeta
    Amare, Meareg
    HELIYON, 2020, 6 (12)
  • [40] Square wave anodic adsorptive stripping voltammetric determination of cefpodoxime proxetil by using pencil graphite electrode
    Sevcan Erden
    Monatshefte für Chemie - Chemical Monthly, 2021, 152 : 587 - 592