Anodic Adsorptive Stripping Voltammetric Determination of Rafoxanide on Glassy Carbon Electrode

被引:1
|
作者
Radi, Abd-elgawad [1 ]
El-samboskany, Hassan [1 ]
机构
[1] Damietta Univ, Fac Sci, Dept Chem, New Damietta 34517, Egypt
关键词
Rafoxanide; anodic adsorptive stripping voltammetry; bovine milk; glassy carbon electrode; cyclic voltammetry; differential pulse voltammetry; PERFORMANCE LIQUID-CHROMATOGRAPHY; CLOSANTEL; PLASMA; NICLOSAMIDE; MUSCLES; BOVINE; HPLC;
D O I
10.2174/1386207323666200422083339
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Aims and Objective: The development of easy, accurate, reliable technique which is characterized by low cost, minimal sample pre-treatment, and short analysis time to monitor RFX residues in milk samples before distribution to consumers. Background: Literature survey reveals several analytical methods, including high-performance liquid chromatography (HPLC), ultra-performance liquid chromatography (UPLC) and thin-layer chromatography (TLC)-densitometty. These methods are time consuming, require additional steps like preconcentration or multisolvent extraction, trained technicians, and expensive instruments. Materials and Methods: The electrochemical analysis of RFX was effectively established by the adsorptive stripping method on GCE due to the effective interfacial accumulation of RFX on the electrode surface. The RFX adsorptive accumulation is followed by electrochemical measurement of the accumulated analyte. Results: The electrochemical oxidation of RFX was studied at glassy carbon electrodes (GCE) in Britton-Robinson buffer (BR) solutions over the pH range from 2.0-12.0 using cyclic and differential pulse voltammetry (DPV). The oxidation of the drug was accomplished in a single irreversible, adsorption-controlled step within the pH range 4.0-9.0. Therefore, the application of GCE for a sensitive and selective quantification of RFX by adsorptive stripping voltammetry was reported. This format was satisfactorily applied for the determination of RFX in bovine milk. Limit of detection (LOD) of 1.25 mu g kg(-1) of milk and mean recoveries of 97.8 to 107.5% were achieved. Conclusion: The proposed method might be competitive with the HPLC techniques. The detection limit found for RFX on GCE for milk samples, after medium exchange, was well below the MRLs, the maximum concentration of a veterinary drug residue legally permissible in food, are proposed by the European Medicines Agency.
引用
收藏
页码:1002 / 1009
页数:8
相关论文
共 50 条
  • [1] Adsorptive stripping voltammetric determination of erythromycin at a pretreated glassy carbon electrode
    Wang, HS
    Zhang, AM
    Cui, H
    Liu, DJ
    Liu, RM
    MICROCHEMICAL JOURNAL, 2000, 64 (01) : 67 - 71
  • [2] Determination of triclocarban by direct and adsorptive stripping voltammetric methods on a glassy carbon electrode
    Lacerda Martins Lucio, Maria Monica
    Rolim Severo, Flaviana Justino
    Estevam da Costa, Daniel Jackson
    Lourenco, Anabel Santos
    Ribeiro, Williame Farias
    Bichinho, Katia Messias
    Ugulino de Araujo, Mario Cesar
    ANALYTICAL METHODS, 2015, 7 (07) : 3268 - 3276
  • [3] Anodic stripping voltammetric determination of gold on a polyvinylferrocene coated glassy carbon electrode
    Kavanoz, M
    Gülce, H
    Yildiz, A
    TURKISH JOURNAL OF CHEMISTRY, 2004, 28 (03) : 287 - 297
  • [4] Adsorptive anodic stripping voltammetric determination of antimony(III) on a glassy carbon electrode using rivastigmine as a new chemical receptor
    Sezgin, Hanife Vardar
    Gokcel, H. Ismet
    Dilgin, Yusuf
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 209 : 686 - 694
  • [5] Adsorptive Stripping Voltammetric Determination of Azithromycin at a Glassy Carbon Electrode Modified by Electrochemical Oxidation
    Biljana Nigović
    Analytical Sciences, 2004, 20 : 639 - 643
  • [6] Adsorptive stripping voltammetric determination of azithromycin at a glassy carbon electrode modified by electrochemical oxidation
    Nigovic, B
    ANALYTICAL SCIENCES, 2004, 20 (04) : 639 - 643
  • [7] Adsorptive Voltammetric Determination of Nimesulide at Glassy Carbon Electrode
    El-Sayed, Gamal O.
    Yasin, Shalaby A.
    El Ries, Mohammed A.
    El-Badawy, Azza A.
    LATIN AMERICAN JOURNAL OF PHARMACY, 2009, 28 (05): : 741 - 746
  • [8] Adsorptive voltammetric determination of orthophosphate at a glassy carbon electrode
    Tanaka, T
    Miura, M
    Ishiyama, T
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 2001, 19 (04): : 591 - 599
  • [9] Adsorptive stripping determination of trifluralin on a glassy carbon electrode
    Radi, AE
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2000, 76 (01) : 61 - 68
  • [10] Electrochemistry and Adsorptive Stripping Voltammetric Determination of Amoxicillin on a Multiwalled Carbon Nanotubes Modified Glassy Carbon Electrode
    Rezaei, Behzad
    Damiri, Sajjad
    ELECTROANALYSIS, 2009, 21 (14) : 1577 - 1586