Performance test of residential heat pump after partial optimization using low GWP refrigerants

被引:28
|
作者
In, Sungjin [1 ]
Cho, Keumnam [2 ]
Lim, Byunghan [3 ]
Kim, Hana [3 ]
Youn, Baek [3 ]
机构
[1] Sungkyunkwan Univ, Grad Sch, Suwon 440746, Gyeonggi, South Korea
[2] Sungkyunkwan Univ, Sch Mech Engn, Suwon 440746, Gyeonggi, South Korea
[3] Samsung Elect Co Ltd, Syst Appliances Div, Suwon 440746, South Korea
关键词
Residential heat pump; R-32; L-41b; Partial optimization; Drop-in test; PRESSURE-DROP; CONDENSATION;
D O I
10.1016/j.applthermaleng.2014.04.040
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present study aimed to improve the performance of the residential heat pump using R-32 and L-41b as a HFO blend after partial optimization by modifying heat exchanger and compressor discharge volume as well as providing the drop-in test data using low GWP refrigerants. Cooling and heating capacities, COP, discharge temperature, pressure drop of evaporator and condenser of the residential heat pump system were measured in case of drop-in test and test after partial optimization. Optimal refrigerant charge for R-32 and L-41b systems was less by 18-25% than that of R-410A system. Capacities of R-32 and L-41b systems through the drop-in test showed 105% and 89-94% of those of R-410A system respectively, while the COP of R-32 and L-41b systems showed 99-101% and 104-105% of those of R-410A systems, respectively. Discharge temperatures of R-32 system showed up to 94.7 degrees C, while those of L-41b system showed up to 86.4 degrees C through the drop-in test. Cooling and heating capacities of R-32 and L-41b systems after partial optimization showed 99% and 101% of those of the R-410A system. Discharge temperatures of R-32 and L-41b systems after partial optimization were 81.8 degrees C and 85.2 degrees C under cooling standard mode, while they were 81.7 degrees C and 80.2 degrees C under heating standard mode. Pressure drops of heat exchanger by using L-41b after partial optimization were lower by 8% under cooling mode and 11% under heating mode for condenser and by 21% under cooling standard mode and 7% under heating standard mode for evaporator than those in case of drop-in test. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:315 / 322
页数:8
相关论文
共 50 条
  • [1] Partial load performance test of residential heat pump system with low-GWP refrigerants
    In, Sungjin
    Cho, Keumnam
    Lim, Byunghan
    Lee, Changseon
    APPLIED THERMAL ENGINEERING, 2015, 85 : 179 - 187
  • [2] Parametric studies of heat pump water heater using low GWP refrigerants
    Shen, Bo
    Nawaz, Kashif
    Elatar, Ahmed
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 : 407 - 415
  • [3] COMPARISON ON LOW GWP REFRIGERANTS FOR HIGH TEMPERATURE HEAT PUMP
    Hu, Bin
    Yan, Yuanbo
    Wang, R. Z.
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 1193 - 1202
  • [4] COMPARISON ON LOW GWP REFRIGERANTS FOR HIGH TEMPERATURE HEAT PUMP
    Hu, Bin
    Yan, Yuanbo
    Wang, R. Z.
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 538 - 547
  • [5] Performance simulation of the indoor unit of a heat pump with low-GWP alternative refrigerants
    Vasu, Amal
    Chang, Young Soo
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2025, 39 (02) : 997 - 1007
  • [6] Performance simulation and exergy analysis of a hybrid source heat pump system with low GWP refrigerants
    Wu, Di
    Hu, Bin
    Wang, R. Z.
    RENEWABLE ENERGY, 2018, 116 : 775 - 785
  • [7] Comparative analyses on a batch-type heat pump dryer using low GWP refrigerants
    Singh, Akhilesh
    Sarkar, Jahar
    Sahoo, Rashmi Rekha
    FOOD AND BIOPRODUCTS PROCESSING, 2019, 117 : 1 - 13
  • [8] Analysis and selection on low-GWP refrigerants in cascade heat pump system
    Yan, Hongzhi
    Wang, Ruzhu
    Hu, Bin
    Eikevik, T. M.
    15TH IIR-GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS, 2022, : 1072 - 1080
  • [9] PERFORMANCE OF LOW GWP FLUIDS IN HEAT PUMP SYSTEMS
    Radulovic, Jovana
    JOURNAL OF THERMAL ENGINEERING, 2016, 2 (03): : 748 - 753
  • [10] Performance assessment of optimized heat pump water heaters using low-GWP refrigerants for high- and low-temperature applications
    Kim, Byeongsu
    Lee, DongChan
    Lee, Sang Hun
    Kim, Yongchan
    APPLIED THERMAL ENGINEERING, 2020, 181