Performance test of residential heat pump after partial optimization using low GWP refrigerants

被引:28
|
作者
In, Sungjin [1 ]
Cho, Keumnam [2 ]
Lim, Byunghan [3 ]
Kim, Hana [3 ]
Youn, Baek [3 ]
机构
[1] Sungkyunkwan Univ, Grad Sch, Suwon 440746, Gyeonggi, South Korea
[2] Sungkyunkwan Univ, Sch Mech Engn, Suwon 440746, Gyeonggi, South Korea
[3] Samsung Elect Co Ltd, Syst Appliances Div, Suwon 440746, South Korea
关键词
Residential heat pump; R-32; L-41b; Partial optimization; Drop-in test; PRESSURE-DROP; CONDENSATION;
D O I
10.1016/j.applthermaleng.2014.04.040
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present study aimed to improve the performance of the residential heat pump using R-32 and L-41b as a HFO blend after partial optimization by modifying heat exchanger and compressor discharge volume as well as providing the drop-in test data using low GWP refrigerants. Cooling and heating capacities, COP, discharge temperature, pressure drop of evaporator and condenser of the residential heat pump system were measured in case of drop-in test and test after partial optimization. Optimal refrigerant charge for R-32 and L-41b systems was less by 18-25% than that of R-410A system. Capacities of R-32 and L-41b systems through the drop-in test showed 105% and 89-94% of those of R-410A system respectively, while the COP of R-32 and L-41b systems showed 99-101% and 104-105% of those of R-410A systems, respectively. Discharge temperatures of R-32 system showed up to 94.7 degrees C, while those of L-41b system showed up to 86.4 degrees C through the drop-in test. Cooling and heating capacities of R-32 and L-41b systems after partial optimization showed 99% and 101% of those of the R-410A system. Discharge temperatures of R-32 and L-41b systems after partial optimization were 81.8 degrees C and 85.2 degrees C under cooling standard mode, while they were 81.7 degrees C and 80.2 degrees C under heating standard mode. Pressure drops of heat exchanger by using L-41b after partial optimization were lower by 8% under cooling mode and 11% under heating mode for condenser and by 21% under cooling standard mode and 7% under heating standard mode for evaporator than those in case of drop-in test. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:315 / 322
页数:8
相关论文
共 50 条
  • [31] LOW-GWP REFRIGERANTS: PERFORMANCE ASSESSMENT AND SELECTION TRADEOFFS
    Domanski, Piotr A.
    Brignoli, Riccardo
    Brown, J. Steven
    Kazakov, Andrei F.
    McLinden, Mark O.
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 21 - 32
  • [32] LOW-GWP REFRIGERANTS: PERFORMANCE ASSESSMENT AND SELECTION TRADEOFFS
    Domanski, Piotr A.
    Brignoli, Riccardo
    Brown, J. Steven
    Kazakov, Andrei F.
    McLinden, Mark O.
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 676 - 687
  • [33] Condensation heat transfer characteristics and energy conversion performance analysis for low GWP refrigerants in plate heat exchangers
    Jung, Jae Hoon
    Ko, Yun Mo
    Kang, Yong Tae
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 166
  • [34] PROPERTY AND PERFORMANCE MEASUREMENTS OF LOW GWP FLUIDS FOR AC AND HEAT PUMP APPLICATIONS
    Leck, T.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 2618 - 2625
  • [35] Vapor compression heat pumps with pure Low-GWP refrigerants
    Wu, Di
    Hu, Bin
    Wang, R. Z.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2021, 138
  • [36] Test Results of Low-GWP Alternative Refrigerants for Refrigeration Applications
    Wang, Xudong
    Amrane, Karim
    2013 ASHRAE ANNUAL CONFERENCE, 2013,
  • [37] Energy, exergoeconomic and environmental optimization of a cascade refrigeration system using different low GWP refrigerants
    Deymi-Dashtebayaz, Mahdi
    Sulin, Alexander
    Ryabova, Tatyana
    Sankina, Iuliia
    Farahnak, Mehdi
    Nazeri, Reza
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2021, 9 (06):
  • [38] Exergy analysis of organic Rankine cycle for waste heat recovery using low GWP refrigerants
    E Elahi A.
    Mahmud T.
    Alam M.
    Hossain J.
    Biswas B.N.
    International Journal of Thermofluids, 2022, 16
  • [39] Exergy analysis of heat pump air conditioning systems for pure electric vehicle use with low-GWP refrigerants
    Lei, Shurong
    Guo, Bin
    Zhao, Ziliang
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 156 : 266 - 277
  • [40] Thermodynamic assessment of a condenser outlet split ejector-based high temperature heat pump cycle using various low GWP refrigerants
    Bai, Tao
    Yan, Gang
    Yu, Jianlin
    ENERGY, 2019, 179 : 850 - 862