Performance test of residential heat pump after partial optimization using low GWP refrigerants

被引:28
|
作者
In, Sungjin [1 ]
Cho, Keumnam [2 ]
Lim, Byunghan [3 ]
Kim, Hana [3 ]
Youn, Baek [3 ]
机构
[1] Sungkyunkwan Univ, Grad Sch, Suwon 440746, Gyeonggi, South Korea
[2] Sungkyunkwan Univ, Sch Mech Engn, Suwon 440746, Gyeonggi, South Korea
[3] Samsung Elect Co Ltd, Syst Appliances Div, Suwon 440746, South Korea
关键词
Residential heat pump; R-32; L-41b; Partial optimization; Drop-in test; PRESSURE-DROP; CONDENSATION;
D O I
10.1016/j.applthermaleng.2014.04.040
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present study aimed to improve the performance of the residential heat pump using R-32 and L-41b as a HFO blend after partial optimization by modifying heat exchanger and compressor discharge volume as well as providing the drop-in test data using low GWP refrigerants. Cooling and heating capacities, COP, discharge temperature, pressure drop of evaporator and condenser of the residential heat pump system were measured in case of drop-in test and test after partial optimization. Optimal refrigerant charge for R-32 and L-41b systems was less by 18-25% than that of R-410A system. Capacities of R-32 and L-41b systems through the drop-in test showed 105% and 89-94% of those of R-410A system respectively, while the COP of R-32 and L-41b systems showed 99-101% and 104-105% of those of R-410A systems, respectively. Discharge temperatures of R-32 system showed up to 94.7 degrees C, while those of L-41b system showed up to 86.4 degrees C through the drop-in test. Cooling and heating capacities of R-32 and L-41b systems after partial optimization showed 99% and 101% of those of the R-410A system. Discharge temperatures of R-32 and L-41b systems after partial optimization were 81.8 degrees C and 85.2 degrees C under cooling standard mode, while they were 81.7 degrees C and 80.2 degrees C under heating standard mode. Pressure drops of heat exchanger by using L-41b after partial optimization were lower by 8% under cooling mode and 11% under heating mode for condenser and by 21% under cooling standard mode and 7% under heating standard mode for evaporator than those in case of drop-in test. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:315 / 322
页数:8
相关论文
共 50 条
  • [21] R1234yf and R1234ze(E) as low-GWP refrigerants for residential heat pump water heaters
    Nawaz, Kashif
    Shen, Bo
    Elatar, Ahmed
    Baxter, Van
    Abdelaziz, Omar
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 82 : 348 - 365
  • [22] Heating performance of recuperative heat pump using low-GWP mixed refrigerant
    Luo J.
    Yang K.
    Zhao Z.
    Wang Q.
    Chen G.
    Huagong Xuebao/CIESC Journal, 2021, 72 : 84 - 90
  • [23] Energy consumption and increased EV range evaluation through heat pump scenarios and low GWP refrigerants in the new test procedure WLTP
    Yu, Binbin
    Yang, Jingye
    Wang, Dandong
    Shi, Junye
    Chen, Jiangping
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2019, 100 : 284 - 294
  • [24] Refrigeration unit and heat pump using low GWP refrigerant
    冷凍機・ヒートポンプの低 GWP 冷媒対応
    1600, Kobe Steel Ltd (70): : 65 - 68
  • [25] MODELING AND ANALYSIS OF GROUND-SOURCE HEAT PUMP SYSTEM ON LOW GWP REFRIGERANTS FOR DOMESTIC APPLICATIONS
    Ostapenko, Oleksii
    Yakovleva, Olga
    Khmelniuk, Mykhailo
    Trandafilov, Vladimir
    9TH INTERNATIONAL CONFERENCE ON COMPRESSORS AND COOLANTS, 2017, : 260 - 267
  • [26] PERFORMANCE ANALYSIS OF LOW GWP REFRIGERANTS IN A NOVEL DIRECT EXPANSION SOLAR ASSISTED EJECTORHEAT PUMP SYSTEM
    Zou, Lingeng
    Liu, Ye
    Yu, Jianlin
    3RD IIR CONFERENCE ON HFO REFRIGERANTS AND LOW GWP BLENDS, 2023, : 129 - 141
  • [27] HYBRID SUPERMARKET SYSTEM USING LOW GWP REFRIGERANTS
    Rinne, F.
    Minor, B.
    Salem, K.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 2131 - +
  • [28] Theoretical evaluation of energy, exergy, and minimum superheat in a high-temperature heat pump with low GWP refrigerants
    Sulaiman, Adam Y.
    Cotter, Donal
    Arpagaus, Cordin
    Hewitt, Neil
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 153 : 99 - 109
  • [29] Pool boiling performance of enhanced tubes on low GWP refrigerants
    Byun, Ho-Won
    Kim, Dong Ho
    Yoon, Seok Ho
    Song, Chan Ho
    Lee, Kong Hoon
    Kim, Ook Joong
    APPLIED THERMAL ENGINEERING, 2017, 123 : 791 - 798
  • [30] The life cycle climate performance evaluation of low-GWP refrigerants for domestic heat pumps
    Yang, Changru
    Seo, Sangwon
    Takata, Nobuo
    Thu, Kyaw
    Miyazaki, Takahiko