Comparative analyses on a batch-type heat pump dryer using low GWP refrigerants

被引:27
|
作者
Singh, Akhilesh [1 ]
Sarkar, Jahar [1 ]
Sahoo, Rashmi Rekha [1 ]
机构
[1] Indian Inst Technol BHU, Dept Mech Engn, Varanasi 221005, Uttar Pradesh, India
关键词
Heat pump dryer; Low-GWP refrigerant; Specific moisture extraction rate; Water activity; Exergy destruction; Experimentation; DRYING CONDITIONS; PERFORMANCE; SIMULATION; CO2; MODEL; QUALITY;
D O I
10.1016/j.fbp.2019.06.009
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The simulation of batch type open cycle heat pump dryer has been performed to study the system performances and food quality using promising low GWP refrigerants (R290, R600a, R32, R152a and R1234yf) as a substitute of R134a for carrot and banana drying. The experimentation with heat pump dryer test facility using R134a has been performed for model validation. Effects of drying time and material moisture content on the coefficient of performance, moisture extraction rate, specific moisture extraction rate, specific energy consumption, drying efficiency, exergy destruction, exergy efficiency and product water activity have been investigated. Results show that moisture extraction rate is maximum for R32, specific moisture extraction rate is maximum for R152a, specific energy consumption is minimum for R152a, drying efficiency is maximum for R152a (average value is 29.74%) and exergy destruction is minimum for R152a for the same air inlet velocity of 2 m/s, respectively. The present study reveals that R152a may be a potential option for heat pump dryer by considering performances, environmental safety (low GWP) and personal safety (low flammability). (C) 2019 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [1] DRYING PERFORMANCE OF COFFEE IN A BATCH-TYPE HEAT PUMP DRYER
    Fernando, A. J.
    Amaratunga, K. S. P.
    Madhushanka, H. T. N.
    Jayaweera, H. R. Y. S.
    TRANSACTIONS OF THE ASABE, 2021, 64 (04) : 1237 - 1245
  • [2] Experimental energy, exergy, economic and exergoeconomic analyses of batch-type solar-assisted heat pump dryer
    Singh, Akhilesh
    Sarkar, Jahar
    Sahoo, Rashmi Rekha
    RENEWABLE ENERGY, 2020, 156 : 1107 - 1116
  • [3] Investigation on Drying Performance and Energy Savings of the Batch-Type Heat Pump Dryer
    Lee, Kong Hoon
    Kim, Ook Joong
    DRYING TECHNOLOGY, 2009, 27 (04) : 565 - 573
  • [4] Parametric studies of heat pump water heater using low GWP refrigerants
    Shen, Bo
    Nawaz, Kashif
    Elatar, Ahmed
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 : 407 - 415
  • [5] COMPARISON ON LOW GWP REFRIGERANTS FOR HIGH TEMPERATURE HEAT PUMP
    Hu, Bin
    Yan, Yuanbo
    Wang, R. Z.
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 1193 - 1202
  • [6] COMPARISON ON LOW GWP REFRIGERANTS FOR HIGH TEMPERATURE HEAT PUMP
    Hu, Bin
    Yan, Yuanbo
    Wang, R. Z.
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 538 - 547
  • [7] Performance test of residential heat pump after partial optimization using low GWP refrigerants
    In, Sungjin
    Cho, Keumnam
    Lim, Byunghan
    Kim, Hana
    Youn, Baek
    APPLIED THERMAL ENGINEERING, 2014, 72 (02) : 315 - 322
  • [8] Analysis and selection on low-GWP refrigerants in cascade heat pump system
    Yan, Hongzhi
    Wang, Ruzhu
    Hu, Bin
    Eikevik, T. M.
    15TH IIR-GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS, 2022, : 1072 - 1080
  • [9] Performance simulation of the indoor unit of a heat pump with low-GWP alternative refrigerants
    Vasu, Amal
    Chang, Young Soo
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2025, 39 (02) : 997 - 1007
  • [10] Selection and validation on low-GWP refrigerants for a water-source heat pump
    Yan, Hongzhi
    Wu, Di
    Liang, Junyu
    Hu, Bin
    Wang, R. Z.
    APPLIED THERMAL ENGINEERING, 2021, 193