Comparative analyses on a batch-type heat pump dryer using low GWP refrigerants

被引:27
|
作者
Singh, Akhilesh [1 ]
Sarkar, Jahar [1 ]
Sahoo, Rashmi Rekha [1 ]
机构
[1] Indian Inst Technol BHU, Dept Mech Engn, Varanasi 221005, Uttar Pradesh, India
关键词
Heat pump dryer; Low-GWP refrigerant; Specific moisture extraction rate; Water activity; Exergy destruction; Experimentation; DRYING CONDITIONS; PERFORMANCE; SIMULATION; CO2; MODEL; QUALITY;
D O I
10.1016/j.fbp.2019.06.009
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The simulation of batch type open cycle heat pump dryer has been performed to study the system performances and food quality using promising low GWP refrigerants (R290, R600a, R32, R152a and R1234yf) as a substitute of R134a for carrot and banana drying. The experimentation with heat pump dryer test facility using R134a has been performed for model validation. Effects of drying time and material moisture content on the coefficient of performance, moisture extraction rate, specific moisture extraction rate, specific energy consumption, drying efficiency, exergy destruction, exergy efficiency and product water activity have been investigated. Results show that moisture extraction rate is maximum for R32, specific moisture extraction rate is maximum for R152a, specific energy consumption is minimum for R152a, drying efficiency is maximum for R152a (average value is 29.74%) and exergy destruction is minimum for R152a for the same air inlet velocity of 2 m/s, respectively. The present study reveals that R152a may be a potential option for heat pump dryer by considering performances, environmental safety (low GWP) and personal safety (low flammability). (C) 2019 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [41] Thermodynamic assessment of high-temperature heat pumps using Low-GWP HFO refrigerants for heat recovery
    Kondou, Chieko
    Koyama, Shigeru
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 53 : 126 - 141
  • [42] Heat-transfer assessment of the low GWP substitutes for traditional HFC refrigerants
    Longo, Giovanni A.
    Righetti, Giulia
    Zilio, Claudio
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 139 : 31 - 38
  • [43] Condensation heat transfer performance and integrated correlations of low GWP refrigerants in plate heat exchangers
    Ko, Yun Mo
    Jung, Jae Hoon
    Sohn, Sangho
    Song, Chan Ho
    Kang, Yong Tae
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 177
  • [44] Low-GWP refrigerants in heat pumps: An experimental investigation of the influence of an internal heat exchanger
    Hoeges, Christoph
    Klingebiel, Jonas
    Venzik, Valerius
    Brach, Jona
    Roy, Philipp
    Neumann, Kaj
    Vering, Christian
    Mueller, Dirk
    ENERGY CONVERSION AND MANAGEMENT-X, 2024, 24
  • [45] Carbonization of johkasou sludge using batch-type equipment
    Katoh H.
    Watanabe T.
    Ohmori H.
    Kawamura K.
    Makino Y.
    Journal of Material Cycles and Waste Management, 2005, 7 (1) : 55 - 64
  • [46] Adsorption heat pump using HFC refrigerants
    Riffat, SB
    Williams, MD
    Corr, S
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1997, 21 (06) : 481 - 494
  • [47] Heating performance of recuperative heat pump using low-GWP mixed refrigerant
    Luo J.
    Yang K.
    Zhao Z.
    Wang Q.
    Chen G.
    Huagong Xuebao/CIESC Journal, 2021, 72 : 84 - 90
  • [49] Second Law Analysis of a Mobile Air Conditioning System with Internal Heat Exchanger Using Low GWP Refrigerants
    Perez-Garcia, Vicente
    Belman-Flores, Juan M.
    Rodriguez-Munoz, Jose L.
    Rangel-Hernandez, Victor. H.
    Gallegos-Munoz, Armando
    ENTROPY, 2017, 19 (04):
  • [50] Optimization of energy utilization and productivity of heat treating batch-type furnaces
    Thermal Processing Laboratory , Department of Mechanical Engineering, 1280 Main St. West, Hamilton, ON, L8S 4L7, Canada
    J. ASTM Int., 2008, 1